D-Link DWS-3160-24TC [515/983] Restrictions

D-Link DWS-3160-24PC [515/983] Restrictions
DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
511
disable - Specifies to disable event notification.
error_frame_period - Specifies error frame period.
threshold - Specifies a threshold range between 0 and 4294967295.
<range 0-4294967295> -Specifies a threshold range between 0 and 4294967295.
window - The range is 148810 to 100000000ms.
<number 148810-100000000> - The range is 148810 to 100000000ms.
notify_state - Specifies the event notification status. The default state is enabled.
enable - Specifies to enable event notification.
disable
- Specifies to disable event notification.
critical_link_eventSpecifies critical link event.
dying_gasp - An unrecoverable local failure condition has occurred.
critical_event - An unspecified critical event has occurred.
notify_state - Specifies the event notification status. The default state is enabled.
enable - Specifies to enable event notification.
disable - Specifies to disable event notification.
remote_loopback - Specifies remote loop.
start - If start is specified, it will request the peer to change to the remote loopback mode.
stop
- If stop is specified, it will request the peer to change to the normal operation mode.
received_remote_loopback - Specifies receive remote loop-back.
process - Specifies to process the received Ethernet OAM remote loopback command.
ignore - Specifies to ignore the received Ethernet OAM remote loopback command. The
default method is ignore”.
Restrictions
Only Administrators and Operators can issue this command.
Example
To configure Ethernet OAM on ports 1 to 2 in active mode:
DWS-3160-24PC:admin# config ethernet_oam ports 1-2 mode active
Command: config ethernet_oam ports 1-2 mode active
Success.
DWS-3160-24PC:admin#
To enable Ethernet OAM on port 1:
DWS-3160-24PC:admin# config ethernet_oam ports 1 state enable
Command: config ethernet_oam ports 1 state enable
Success.
DWS-3160-24PC:admin#
To configure the error symbol threshold to 2 and period to 1000ms for port 1:
DWS-3160-24PC:admin# config ethernet_oam ports 1 link_monitor error_symbol
threshold 2 window 1000 notify_state enable
Command: config ethernet_oam ports 1 link_monitor error_symbol threshold 2
window 1000 notify_state enable
Success.