Frico ar220e18 [22/56] Ar 200 a e w
![Frico ar220e18 [22/56] Ar 200 a e w](/views2/1230819/page22/bg16.png)
22
GB
AR 200 A/E/W
Basic setting of fan speed
The fan speed when the door is open is
set using the speed control. Note that
the air flow direction and speed may
need fine adjustment depending on the
loading of the door.
Filter (AR200W)
The heating coil is protected by an air
filter which covers the coil face.
Service, repairs and maintenance
For all service, repair and maintenance
first carry out the following:
1. Disconnect the power supply.
2.The base plate/service hatch is opened
by loosening the snap fixings located
on the down side (turn 90°) and then
loosening the base plate from the rim.
See fig. 3 and 4.
3. After service, repair and maintenance
close the base plate/service hatch and
make sure that the snap fixings lock
properly.
Maintenance
The appliance filter should be cleaned
regularly to ensure the air curtain
effect and the heat emission from the
device. How often depends on local
circumstances. A clogged filter is not a
risk, but the appliance function can fail.
1 Disconnect the power.
2.The base plate/service hatch is opened
by loosening the snap fixings located
on the down side (turn 90°) and then
loosening the base plate from the rim.
See fig. 3 and 4.
3 Remove the filter and vacuum clean
or wash it. If the filter is clogged, it may
need to be changed.
Since fan motors and other components
are maintenance free, no maintenance
other than regular cleaning is necessary.
The frequency of cleaning can vary
depending on local conditions, but
undertake cleaning at least twice a year.
Inlet and exhaust grilles, impeller and
elements can be vacuum cleaned or
wiped using a dry cloth. Use a brush
when vacuuming to prevent damaging
sensitive parts. Avoid the use of strong
alkaline or acidic cleaning agents.
Overheating
The air curtain unit with electric heater
is equipped with an overheat protector.
If this is deployed due to overheating,
reset as follows:
1. Disconnect the electricity using the
omnipolar switch.
2. Allow the electrical coil to cool.
3. Determine the cause of overheating
and rectify the fault.
Reset is performed as follows:
1. Locate the red button inside the
air curtain unit. This is visible and
accessible by opening the base plate.
The button is located outside the
connection box. On the 2-metre
variant, a red button is located
outside each connection space.
2. Press the red button until a click is
heard.
3. Connect the air curtain again.
The motors in all the air curtain units
have a built-in thermal safety cut-out
to protect against overheating. This will
reset automatically once the motor has
cooled.
Fan replacement
1. Determine which of the fans is not
functioning.
2. Disconnect the cables to the relevant
fan.
3. Remove the screws securing the fan
and lift the fan out.
4. Install the new fan in reverse order to
the above.
cont. on next page
Содержание
- Thermozone ar 200 a e w 1
- Ar 200 a e w 2
- Dimensions and connections 2
- Ar 200 a e w 3
- Mounting and installation 3
- Ar 200 a e w 4
- Accessories 5
- Ar 200 a e w 5
- Vr20 25 5
- Water regulators 5
- Ar 200 a e w 6
- Internal ambient regulation option 6
- Switching box brass plates 6
- Wiring diagrams ar200a 6
- Wiring diagrams ar200e 6
- Ar 200 a e w 7
- Internal 7
- Master slave 7
- Wiring diagrams ar 200 e 7
- Ar 200 a e w 8
- Ar 200 a e w 9
- Ar 200 a e w 10
- Ar 200 a e w 11
- Level 1 11
- Level 2 11
- Wiring diagrams ar200e 11
- 3 4 5 6 7 12
- Ar 200 a e w 12
- Ar200w 12
- Ar210w ar215w ar220w 12
- Ar215w 3µf ar210w 12
- Ar220w 3µf 10µf 14µf 12
- Door contact 12
- L 2 1 5 3 4 6 7 n 12
- L n 2 1 3 6 4 5 12
- Level 1 12
- Level 2 12
- V motor and control 12
- Wiring diagrams ar200 w 12
- Μf 4µf 12
- Μf 6µf 12µf 12
- Ar 200 a e w 13
- Output charts water 13
- Ar 200 a e w 14
- Dimensioneringstabeller vatten 14
- 1 conditions distance to the unit 5 metres directional factor 2 equivalent absorption area 200 m² 2 t temperature rise of passing air at maximum heat output and lowest highest airflow 3 applicable at water temperature 80 60 c air temperature in 15 c 15
- Ar 200 a e w 15
- Ar200e is delivered as 9 kw 11 kw and 18 kw 400v3n models but they are convertible to 230v and different outputs as shown in above table 15
- Protection class ar200a e w normal design ip20 ce compliant 15
- Technical specifications thermozone ar 200 a without heat 1 15
- Technical specifications thermozone ar 200 e electrically heated 3 15
- Technical specifications thermozone ar 200 w water heated 2 15
- Ar 200 a e w 16
- Montage och bruksanvisning 16
- Ar 200 a e w 17
- Ar 200 a e w 18
- Ar 200 a e w 19
- Ar 200 a e w 20
- Assembly and operating instructions 20
- Ar 200 a e w 21
- Ar 200 a e w 22
- Ar 200 a e w 23
- Ar 200 a e w 24
- Ar 200 a e w 25
- Monterings og bruksanvisning 25
- Ar 200 a e w 26
- Ar 200 a e w 27
- Ar 200 a e w 28
- Ar 200 a e w 29
- Consignes de montage et mode d emploi 29
- Ar 200 a e w 30
- Ar 200 a e w 31
- Ar 200 a e w 32
- Ar 200 a e w 33
- Ar 200 a e w 34
- Montage und betriebsanleitung 34
- Ar 200 a e w 35
- Ar 200 a e w 36
- Ar 200 a e w 37
- Ar 200 a e w 38
- Ar 200 a e w 39
- Instrucciones de instalación y uso 39
- Ar 200 a e w 40
- Ar 200 a e w 41
- Ar 200 a e w 42
- Ar 200 a e w 43
- Ar 200 a e w 44
- Montage en bedieningsinstructies 44
- Ar 200 a e w 45
- Ar 200 a e w 46
- Ar 200 a e w 47
- Ar 200 a e w 48
- Ar 200 a e w 49
- Istruzioni operative e di installazione 49
- Ar 200 a e w 50
- Ar 200 a e w 51
- Ar 200 a e w 52
- Ar 200 a e w 53
Похожие устройства
- Frico ar215w Инструкция по эксплуатации
- Frico ar215e11 Инструкция по эксплуатации
- Frico ar210w Инструкция по эксплуатации
- Frico ar210e09 Инструкция по эксплуатации
- Frico ad220w Инструкция по эксплуатации
- Frico ad215w Инструкция по эксплуатации
- Frico ad210w Инструкция по эксплуатации
- Frico swh33 Инструкция по эксплуатации
- Frico swh32 Инструкция по эксплуатации
- Frico swh22 Инструкция по эксплуатации
- Frico swh12 Инструкция по эксплуатации
- Frico swh02 Инструкция по эксплуатации
- Frico swh02 Инструкция по эксплуатации
- Frico pa4210e12 Инструкция по эксплуатации
- Frico pa4215e18 Инструкция по эксплуатации
- Frico pa4220e24 Инструкция по эксплуатации
- Frico pa4225e30 Инструкция по эксплуатации
- Frico ar320e18 Инструкция по эксплуатации
- Frico ar315e14 Инструкция по эксплуатации
- Frico ar310w Инструкция по эксплуатации