Timberk whe 5.5 xtr h1 [15/36] English
![Timberk whe 5.5 xtr h1 [15/36] English](/views2/1240104/page15/bgf.png)
15
www.timberk.com electric instant water heater
Water Heater Operation
1. During the first water heater start-up or after long-term non-use, fill
the device with water by opening the cut-off tap at cold water
supply line, and make sure that there is a steady cold water flow at
water outlet at the consumption point, after that switch on the
device power supply, indicating lamp 1 at the control panel (see
Fig.15) starts blinking.
2. To switch on the device, press « » button at the control panel,
power supply indicator 1 (see Fig.15) will be constantly lit up.
3. Water temperature can be set within +35° to +60° range with the
help of « » button (value increase) and « » (value decrease). If
water heater does not heat up to the temperature set, water flow
shall be reduced with the help of the tap at the inlet nozzle.
4. Water flow is controlled by the tap at water inlet to or outlet from
water heater. When there is water flow, and water pressure is not
less than 0.1 MPa, heating is switched on automatically, and
indicating lamp 2 located at the control panel lights up (see Fig.15).
5. After heating is switched on, you need to wait for 10-20 seconds to
let temperature of heated water stabilize.
6. Incoming water is heated up inside the heating flask when it is
flowing through the heating element. Water temperature in the
water supply main may vary depending on a season from +3° to
+20°, so, in winter water flow shall be less than in summer to
assure the optimum water temperature.
To switch off the water heater, simply close water flow at the inlet
to or outlet from the device; electronic flow sensor automatically
opens the circuit of power supply to heating element, and
indicating lamp 2 located at the control panel goes down (see
Fig.15), and power supply indicator 1 starts blinking. For the
subsequent switching on of heating it is enough to reopen the
water supplying or water draining tap.
7. Temperature switch stops the power supply to heating element in
the event of water overheating inside water heater. If water heater
is connected to the electric main, and water heating is switched on,
ATTENTION!
Do not switch on the water heater if there are grounds to suspect
that water inside it has frozen.
but water is not heated up, it means that the temperature switch
has tripped out or was not enabled. To return the water heater to
operating mode, the button at temperature switch shall be pressed.
Proceed as follows:
- Switch off the power supply to water heater, remove the front
panel, press the black button located in the central part of
temperature switch till it clicks; the temperature switch is located at
water heater flask.
ENGLISH
ATTENTION!
If these activities have not resulted in any positive outcome or tem-
perature switch trips out repeatedly within a short period of time,
switch off power supply to water heater, close water supply to water
heater and address the Authorized Timberk Service Center located
at your region to receive any advice or maintenance. For the address
of the Authorized Service Center, please, consult with the seller or
visit our web-site at .www.timberk.com
Содержание
- Electric instant water heater 1
- Instruction manual 1
- Models 1
- English 3
- English 5
- English 7
- English 9
- Fig 14 10
- English 11
- English 13
- English 15
- During use of the water heater scale may appear in nozzle openings of the shower spout this reduces efficiency of heating deteriorates water spray ing and increases water pressure in the heating vessel for prevention of such phenomena it is necessary to periodically clean the nozzle using household chemical agents and soft brushes do not use abrasive cleaning substances and inappropriate chemical agents a outer care switch off the appliance and allow it to fully cool down clean the outer surface of the appliance enclosure using a slightly moist ened soft cloth and then wipe it dry do not use abrasive cleaning sub stances b filter cleaning if water flow rate from the heater decreases it is necessary to clean the coarse filter installed at the cold water inlet to the water heater use the following procedure switch off the appliance and allow it to fully cool down shut off cold water feeding unscrew the cold water feed hose from the water heater remove the coarse strainer and flush it und 16
- Maintenance 16
- Possible causes 16
- Possible malfunctions and methods of their elimination are given in table 4 table 4 16
- Problem 16
- Troubleshooting 16
- Troubleshooting method 16
- Disposal upon expiration of service life the water heater shall be disposed for more details regarding disposal of the water heater please contact a representative of the local authorities service life of a device is 5 years 17
- Electrical schematic diagram 17
- English 17
- Power card 17
- Watermaster i series water heater models whe 3 xtr h1 whe 4 xtn z1 whe 6 xtr h1 whe 5 xtr h1 17
- Watermaster ii series water heater models whe 5 xtn z1 whe 6 xtn z1 whe 6 xtn z1 whe 7 xtn z1 whe 8 xtn z1 17
- Watermaster iii series water heater models whe 12 xtl c1 whe 18 xtl c1 whe 21 xtl c1 whe 24 xtl 1 17
- Www timberk com e instant water heater lectric 17
- Watermaster ii 3 4 23
- Watermaster iii 5 6 23
- Timberk www timberk com 32
- Watermaster i whe 3 xtr h1 whe 4 xtr h1 whe 5 xtr h1 33
- Watermaster ii whe 5 xtn z1 whe 6 xtn z1 whe 6 xtn z1 whe 7 xtn z1 whe 8 xtn z1 33
- Watermaster iii whe 12 xtl c1 whe 18 xtl c1 whe 21 xtl c1 whe 24 xtl c1 33
- Timberk 34
- Www btpart ru 35
Похожие устройства
- Timberk whe 3.5 xtr h1 Инструкция по эксплуатации
- Timberk whe 4.5 xtr h1 Инструкция по эксплуатации
- Timberk tec.ps1 el15 in (rb) Инструкция по эксплуатации
- Timberk dh tim 60 e1w Инструкция по эксплуатации
- Timberk tih r3 3m Инструкция по эксплуатации
- Timberk tih r2s 3квт Инструкция по эксплуатации
- Timberk tih r2 3квт Инструкция по эксплуатации
- Timberk tih q1 3 квт Инструкция по эксплуатации
- Timberk swh re1 80 v Инструкция по эксплуатации
- Timberk tih r1 9 квт Инструкция по эксплуатации
- Timberk tih r1 6 квт Инструкция по эксплуатации
- Timberk tih r1 5 квт Инструкция по эксплуатации
- Timberk tih r1 3 квт Инструкция по эксплуатации
- Timberk thc ws2 6m aero Инструкция по эксплуатации
- Timberk tgh 4200 sm2 Инструкция по эксплуатации
- Timberk tgh 4200 sm1 Инструкция по эксплуатации
- Dantex RK-18SKGI/RK-18SKGIE Руководство пользователя
- Dantex RK-24SKGI/RK-24SKGIE Руководство пользователя
- Dantex RK-09SKGI/RK-09SKGIE Руководство пользователя
- Dantex RK-12SKGI/RK-12SKGIE Руководство пользователя