– 3
NOTICE
The higher the level sensor is adjusted, the higher the
switch-on and switch-off point.
See the following table for application examples:
Set the switch to automatic mode (AUTO).
Insert the mains plug into the socket.
NOTICE
In manual operation the pump remains switched on
continuously.
Illustration
Set the switch to manual operation (MAN).
Insert the mains plug into the socket.
ATTENTION
Risk of damage! Dry running leads to increased wear;
never leave the pump unattended during manual oper-
ation. Unplug immediately in case of dry running
It is recommended to use manual mode to reach the
min. residual fluid height of 1 mm.
A check valve is installed for the SP 6 Flat Inox. This
prevents residual fluid in the hose from flowing back af-
ter the pumping process finishes.
NOTICE
Soiling can deposit and lead to malfunctions.
Pump clear water or thoroughly rinse the pump af-
ter every use.
This especially applies after pumping chlorinated
water or other liquids that leave residue.
Disconnect the main plug from the socket.
The pump is maintenace-free.
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance during transport (see Spec-
ifications).
Lift and carry the pump on the carrying handle.
If you want to transport the appliance on a vehicle
secure it from slipping.
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance when selecting a storage lo-
cation for it (see Specifications).
Completely drain the pump and allow it to dry.
Store the pump in a frost-free place.
Min / Max SP 6 Flat Inox SP 7 Dirt Inox
Shaft with a diame-
ter < of approx.
1 m (e.g. drainage)
Level sensor in
the upmost po-
sition
Level sensor in
the upmost posi-
tion
It is recom-
mended to use
the pre-filter.
Pre-filter flaps
closed (protec-
tion against soil-
ing)
Float basin, pond
(only SP 7 Flat In-
ox) or something
similar
Level sensor in
the lowest posi-
tion
Level sensor in
the lowest posi-
tion
Start pumping
operations with
pre-filter or
folded out sup-
port legs
Pre-filter flaps
closed (protec-
tion against soil-
ing)
Continuation
pumping oper-
ations without
pre-filter and
folded in sup-
port legs (resid-
ual fluid height
1 mm is
reached)
Note
Perform in
manual mode.
Check the
switch-off/shal-
low suction.
-
Manual operation
Flat vacuuming (SP 6 Flat Inox)
Finish operation
Maintenance
Transport
Storage
Storing the pump
12 EN