Failure Possible Reason Failure Correction
Loss of the
compressor
capacity
Motor
overheating
and compressor
stop during
operation
Pressure drop in
the receiver -
constant eervescence
when the compressor
is shut down
Compressor stop
during operation
Compressor vibration
during operation. Uneven
humming of the motor.
After shutting down
during the restart the
engine hums, but com-
pressor does not start.
Oil excess in the com-
pressed air and receiver
Compressor shuts
down and starts in
several minutes
After several
attempts to start
the compressor
shuts down
Compressor does
not shut down and
safety valve actuates
Incorrect operation
of the compressor
and pressure relay
Voltage decrease
in the mains
Actuation of the thermal
protection because
of overheating
Actuation of the thermal
protection because
of overheating
Oil level in the crankcase
is above midpoint
Voltage is not available
in the power circuit
Failure of power circuit
Fan failure
Continuous operation
of the compressor under
maximum pressure and
air consumption - actuation
of the thermal protection
Insucient level of oil
in the compressor crankcase
Wear out or clogging
of the reverse valve sealing
Air leakage
from the receiver
Failure of connection
tightness or damage
of air pipeline
Air filter clogging
Clean or replace filtering
element
Determine the leakage place,
tighten the connection,
replace air pipeline
Screw out hexagonal head
of the valve, clean the seat
and sealing gasket or
replace it
Check oil quality
and level, add if necessary
Decrease the compressor
load having decreased
pressure and air consumption.
Restart the compressor.
Visually inspect the fan.
If necessary, replace it in
the authorised service centre.
Check the power circuit
Check the power circuit
Bring the oil level to the norm
Clean the air feeding hoses.
Ventilate the premises.
Check the oil level and quality.
Set the compressor switch
in ON position. Ventilate
the premises. Wait for several
minutes and the compressor
should star automatically.
Check the mains voltage.
Remove all the extension
cables from the electrical
feed circuit.
De-energize the compressor
and contact the authorised
service centre.
TROUBLE SHOOTING
The packaging is made entirely of recyclable materials, which you may dispose at local
recycling facilities. Do not dispose of electrical appliances in household waste. In accordance
with European Directive 2002/96/EC on used electrical and electronic Appliances and its
implementation in national law, used power tools must be collected separately and recycled
in an ecologically compatible manner.
Information on options for disposing of electrical appliances after their useful life can be
obtained from your local or city council. Disposal of the used oils and condensates should be
made with observation of the relevant local regulations because these products contaminate
the environment.

Содержание

Похожие устройства

Скачать