Pontec PondoPress Set 10000 [12/96] Disposal

Pontec PondoPress Set 10000 [12/96] Disposal
12
- GB -
Storage/Over-wintering
Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to be
expected. Drain and thoroughly clean the pressure filter, check for damage. Remove, clean, dry and store all filters in a
frost-free environment. Store the filter pump submerged or filled in a frost-free environment. Do not immerse the plugs!
Ensure that the storage place is inaccessible to children. Cover the filter container such that the ingress of rain water is
excluded. Drain all hoses, pipes and connections as far as possible.
Wearing parts
The UVC lamp, the quartz glass, the filters and the rotor are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Only dispose of the UVC lamp by using the return system provided for this purpose.
Remedy of faults
Malfunction Cause Remedy
Unit has been in operation only for a short time The complete biological cleaning effect is only
achieved after several weeks
Water extremely soiled Remove algae and leaves from the pond,
change the water
Excessive fish and animal population Guide value: approx. 60 cm fish length in 1 m³3
pond water
Foam filters soiled Clean filters
Quartz glass tube soiled Remove UVC and clean quartz glass
The unit performance is not satisfactory
UVC lamp capacity exhausted Replace the lamp after approx. 8,000 operating
hours
Power supply of Filtoclear-UVC not connected Connect UVC power plug
UVC lamp defective Replace the UVC lamp
Connection defective Check electrical connection
UVC lamp display is not lit
UVC overheated UVC automatically switches on when cooled
down
Pump power supply not connected Connect pump power supply
Pond inlet blocked Clean pond inlet
No water outlet from the pond inlet
Filter container/pump housing clogged Clean filter container/pump housing
Guarantee conditions
PfG grants a 2 year guarantee from the date of sale on proven material and manufacturing faults. Prerequisite for our
guarantee is the presentation of the purchase receipt. Our guarantee will become null and void if the unit is misused,
electrically or mechanically damaged by inappropriate use and improper repair by non-authorised workshops. Repairs
are reserved for workshops authorised by PfG or by PfG itself. In the case of warranty claims, please return the defec-
tive unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the
right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier.
Further claims of whatever type, especially consequential damage, are excluded. This guarantee does not affect the
final customer’s claims against the dealer.