Faber AGORA 120 WHITE SC [10/36] En 1 10

Faber AGORA 90 BIANCO SC [10/36] En 1 10
EN
1
10
RECIRCULATION VERSION AIR OUTLET
• Cut a hole ø 125 mm in any shelf that may be positioned over
the hood.
Insert the reducer flange 9 on the hood body outlet.
Connect the flange to the outlet on the shelf over the hood by
using a flexible or rigid pipe ø120 mm.
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Fix the air outlet grid 8 on the recirculation air outlet by using
the 2 screws 12e (2,9 x 9,5) provided.
Ensure that the activated charcoal filters have been inserted.
9
ø 125
8
12e
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm.
Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.