ABAC A39B/90 CT4 [19/96] Fault cause remedy

ABAC A29B/LN/T3 [19/96] Fault cause remedy
19
G
B
FAULT CAUSE REMEDY
Themotorand/orthecompressoroverheat
irregularly.
Insufcientventilation. Improveambientconditions.
Closingofairducts. Checkandifnecessarycleantheairlter.
Insufcientlubrication.
Topuporchangeoil
(gures 17a-17b-17c).
Afteranattempttostartthecompressor,itstops
duetotrippingofthethermalcutoutcausedby
forcingofthemotor.
Start-upwithheadofthecompressorcharged.
Releasethecompressorheadbyusingthe
pressureswitchpushbutton.
Lowtemperature. Improveambientconditions.
Voltagetoolow.
Checkthatthemainsvoltagematchesthatof
thedataplate.Eliminateanyextensions.
Afteranattempttostartthecompressor,itstops
duetotrippingofthethermalcutoutcausedby
forcingofthemotor.
Incorrectorinsufcientlubrication.
Checklevel,topupandifnecessarychange
theoil.
Inefcientelectrovalve. CalltheServiceCenter.
Duringoperation,thecompressorstopsforno
apparentreason.
Trippingofthethermalcutoutofthemotor.
Checkleveloil.
Single-stage, mono-phase versions: operate
onthebuttonofthepressureswitchreturning
thistotheOFFposition(g. 1a).
Resetthethermalcutout(g. 2)andrestart
(gures 1b).
Ifthefaultpersists,calltheServiceCenter.
Versions with delta-star starter:
operateonthebuttonofthethermalcutout
locatedinsidetheboxoftheelectricpanel(g.
3c)andrestart(g. 6d).
Ifthefaultpersists,calltheServiceCenter.
Other versions:
Operateonthebuttonofthepressureswitch
returningthistotheOFFpositionandthento
ONagain(g. 1a-1b).
Ifthefaultpersists,calltheServiceCenter.
Electricfault. CalltheServiceCenter.
Whenoperating,thecompressorvibratesand
themotoremitsanirregularbuzzingsound.Ifit
stops,itdoesnotrestartalthoughthesoundof
themotorispresent.
Single-phase motors:
faultycapacitor.
Havethecapacitorreplaced.
3-phase motors:
Oneofthephasesofthe3-phasepowersupply
ismissingdueprobablytoblowingofafuse.
Checkthefusesinsidetheelectricpanelorthe
electricboxandifnecessaryreplacethosethat
havebeendamaged(g. 18).
Irregularpresenceofoilinthenetwork.
Toomuchoilinsidetheunit. Checkoillevel.
Wearonsegments. CalltheServiceCenter.
Leakingofcondensatefromtheventcock. Presenceofdirt/gritinsidethecock. Cleanthecock.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts. Tampering with the machine may impair