Bertos E7TPB Инструкция по эксплуатации онлайн [130/458] 273545

Bertos E7TPB Инструкция по эксплуатации онлайн [130/458] 273545
130
|
EN
Electronics OK (in stand-by), potentiometer in position O
Faulty or disconnected display
Switching on after the disconnection from the AC mains. Phase L1
and L3 < 150V (if L2 skips, the unit performs poorly)
Software Generator Error
(Standard IO DEVICE 1 o 2 unavailable)
Attention: DC current >350 mA (too many fans are connected or
fans are broken)
Attention: fan not connected or blocked (flash after 5 seconds
from the start-up, then a flash every 1 second for 10 seconds)
In the event that a problem occurs and is not listed in the
above table, call for a qualified technical assistance.
Short-circuit of temperature sensor; too low inductance
temperature (<50°C; flash every 5 seconds)
Too high inductance temperature; temperature sensor interrupted
Pan missing; pan not detected (too small diameter)
Unsuitable pan, inductance short-circuit (too low µh value)
Too high temperature of the heat sink (> 100°C); short-circuit of
the heat sink’s sensor
Too low heat sink temperature (> 1°C); short-circuit of the heat
sink’s sensor
Missing or faulty potentiometer; wrong value (>10,75 kOhm)
Fault Cause Operations to be performed by trained and
authorized personnel
Insufficient power (the operating light is ON) The cooking vessel is not performing
properly
Use a better quality cooking vessel. Compare the power supply
level with the previous vessel
The cooling system is clogged Make sure the air inputs and outputs are free
The air filter is clogged Clean or replace the air filter
Room temperature is too high (the cooling
system can’t keep the correct temperature,
see item 2)
Make sure that the unit does not intake hot air. Reduce
either the temperature of input air or the room temperature
(temperature must not be higher than 40°C / 110 °F)
A phase is missing Check the fuses
The unit is faulty Disconnect the unit and call your retailer
No reaction when the potentiometer is turned
The potentiometer is faulty Disconnect the unit and call your retailer
Alternating power supply (off/on in few
minutes). The fan is ON
The cooling system is clogged Make sure the air inputs and outputs are free
The fan is clogged Clean or replace the fan
Alternating power supply (off/on in few
minutes). The fan is OFF
The fan is faulty Disconnect the unit and call your retailer
Alternating power supply (off/on in few
minutes, occurs after heavy duty)
Overheating of inductance or cooking area Switch the unit off, remove the cooking vessel and wait for the
cooking area to cool down
Empty cooking vessel Switch the unit off, remove the vessel and wait for the cooking
area to cool down
Cooking vessel with overheated oil Switch the unit off, remove the vessel and wait for the cooking
area to cool down
Small metal objects (such as spoons or
knives) are heated if they are rested on the
cooking area
The sensor which detects the presence of the
cooking vessel is regulated incorrectly
Regulate the sensor which detects the presence of the cooking
vessel.
Displayed faults

Содержание

Скачать