ISA Isetta LX 7R TP [31/32] Annex 6
![ISA Isetta LX 7R TP [31/32] Annex 6](/views2/1323204/page31/bg1f.png)
31
ISETTA
USE AND MAINTENANCE MANUAL
428000372237
EN
Annex 6
DECLARATION OF CONFORMITY
We: ISA S.r.l.
Via del Lavoro, 5 - 06083 - Bastia Umbra (PG)
declare under our own responsibility, that the product:
Product: ISETTA
Serial number: .....
To which this declaration refers, is in compliance with e following:
MACHINERY SAFETY
General electric safety Standard EN 60335-1/Ed.2002+Modifi cations A11:2004,A1:2004,A12:2006,A2:2006 + A13:2008
A15:2011. Particular requirements for commercial refrigerating appliances EN 60335-2-89/Ed.2010. Standard for Measuring Electro-
magnetic Fields (EMF) of Electrical Appliances EN 62233:2008, Directive 2006/95/EC of the European Parliament and the Council of 12th
December 2006 on the harmonisation of the Laws of Member States relating to electrical equipment for use within certain voltage limits
EN 62471/Ed.2009 Photo-biologic safety of lamps and lamp systems
ELECTROMAGNETIC COMPATIBILITY (EMC)
Limits and methods of measurement of radio interference characteristics of household appliances and similar motor-operated and
thermal appliances, of equipment, electrical appliances and similar equipment EN 55014-1 (valid until 2009: Ed.2000+Amendments
A1:2001, A2:2002 - or: Ed.2006)
Minimum requirements for household appliances, tools and similar electrical appliances EN 55014-2 (Ed.1997+Amendment A1:2001)
Part 3: Limits – Section 2: Limits for harmonic current emissions (equipment input current=16A per phase)
EN61000-3-2 (valid until 2009:Ed.2000+Modifi cation A2:2005-or:Ed.2006) Part 3:Limits-Section 3:Limitation of voltage fl uctuations and
fl icker in low-voltage supply systems for equipment with rated current=16A EN61000-3-3 (Ed.1995+Modifi cations A1:2001,A2:2005)
Part 4:Testing and measurement techniques Section 2:Electrostatic discharge immunity test EN61000-4-2 (Ed.1995) Part 4:Testing and
measurement techniques Section 4: Electrical fast transient/burst immunity test EN61000-4-4 (Ed.1995)
PRESSURE EQUIPMENT DIRECTIVE (PED) 97/23/EC
As the equipment falls into a class lower than I, it is excluded from the PED’s application fi eld (art.1 par.3.6)
FOODSTUFF COMPATIBILITY
Regulation (CE) N.1935/2004 of the European Parliament and of the Council dated 27 October 2004 Regulation (CE) N.2023/2006 of
the Council dated 22 December, Directive 2008/39/CE of the Council dated 6 March 2008 Directive 2007/19/CE of the Council dated 30
March 2007 Directive 2005/79/CE of the Council dated 18 November 2005 Directive 2004/19/CE of the Council dated 10 March 2004
Directive 2004/1/CE of the Council dated 6 January 2004 Regulation (UE) 10/2011 of the Council dated 14 January 2011
ROHS and WEEE
Directive 2011/95/EC of the European Parliament and of the Council of 8th June 2011
Directive 2002/96/EC of the European Parliament and of the Council of 27th January 2003
REACH
Regulation (CE) n. 1907/2006 of the European parliament and council dated 18 December 2006 concerning the recording, evaluation,
authorisation and restriction of the chemical substances (REACH), which establishes a European Agency regarding chemical substances,
which modifi es the Directive 1999/45/CE and that repeals the Regulation (CEE) n. 793/93 of the Council and the regulation (CE) n.
1488/94 of the Commission 91/155/CEE, 93/105/CE and 2000/21/CE
SUBSTANCES THAT REDUCE THE OZONE LAYER
Regulation (CE) N. 1005/2009 dated 16 September 2009 (Offi cial Journal (OJ) of the European Union 31/10/2009 L286)
According to the requirements set by Directives: 2006/95/EC, 2004/108/EC, 2006/42/EC, 97/23/EC
The person authorised to draw-up the Technical Folder is Mr. Minelli Maurizio (Technical Department Manager)
Via del Lavoro 5 - 06083 Bastia Umbra (PG)
Bastia Umbra: 20 / 03 / 2015
(place and date of issue) Minelli Maurizio
Содержание
- Isetta 1
- Isetta 2
- Notes important notes 4
- Introduction 5
- Manufacturer s contact details 5
- Fixed protective devices 6
- Safety 6
- Safety devices applied 6
- Safety devices included 6
- Staff training 6
- Although the equipment is fi tted with the aforementioned safety devices there are still some risks that cannot be eliminated but reduced via corrective actions by the fi nal integrator and correct operational procedures 7
- Before conducting any maintenance works on the equipment or part of it it is necessary to section the power supply that powers i 7
- Below is a summary of the remaining risks associated with the equipment during 7
- Disconnecting electrical power supply 7
- During design the manufacturer examined all the areas or parts at risk therefore all necessary precautions have been taken to prevent risks to persons and damage to the equipment as mentioned in the previous paragraphs 7
- Normal operation adjustments and tweaking maintenance cleaning 7
- Residual risks 7
- Risk of breaking or damaging the electrical components of the equipment with a possible reduction in safety levels following a short circuit before connecting the electricity supply make sure there is no ongoing maintenance work 7
- Risk of contact with live parts 7
- Circuit faults 8
- Explosions 8
- Slipping 8
- Tripping 8
- Warning sign 8
- Refrigerant r290 9
- Disposing of exhaust materials 10
- Electrical connection 11
- Installation 11
- Installation positioning and ambient conditions 11
- Storage and unpacking 11
- The equipment with or without the packaging should be carefully stored inside warehouses or in areas away from the elements and direct sunlight at a temperature between 0 and 40 c the equipment should only be moved by qualifi ed personnel operating forklift trucks the power of which should be suited to handling the weight of the product during this operation the equipment must be placed on the special pallet supplied 11
- This manual provides information on how to correctly unpack the equipment the procedures to position it and describes how to connect the equipment to the electric network 11
- Unpack the equipment by removing the screws fi xing it to the pallet all packaging materials are recyclable and should be disposed of in accordance with local regulations please destroy plastic bags to prevent them from becoming hazardous to children suffocation 11
- Display containers arrangement 12
- Technical specifications 12
- 6r 7r 9r 12r 13
- Climate class 13
- Defrost w a 13
- Defrosting 13
- Electrical absorption 13
- Environmental conditions 13
- External dimension 13
- Lxpxh mm 13
- Power supply 13
- Product class 13
- Refrigerant 13
- Refrigeration 13
- Safety class cei en 60335 2 89 n c ambient 13
- Standard w a 13
- Technical specifications 13
- Use and maintenance manual 13
- V ph hz 13
- Weight net kg 13
- Installation 14
- Isetta 14
- Load limits 14
- Positioning 14
- Assembled structure 15
- Equipment description 15
- Identifi cation 15
- Insulated structure in ecological polyurethane cooling system electronic control panel electrical system built in hermetic condensing unit lighting rear pivoting methacrilate panel system on operator side 4 pivoting whells 15
- The equipment comprises 15
- The equipment comprises a single furniture on which all the functional devices needed to make it a professional product effi cient for its intended use are assembled 15
- Activate the mains system master switch plug the refrigerated cabinet in at the socket supplied by the customer ensuring that the plug is fi tted with an earth contact and that there are no multiple sockets connected to it press the switch 2 5 to turn the equipment 16
- Control panel 16
- Start up 16
- The control panel is made up from the following components 16
- Displays any alarms if included 17
- User interface ew974 ew978 17
- Check up 18
- Manual activation of the defrosting cycle 18
- Set button 18
- User interface dixell xr44cx 18
- Isetta 19
- Cleaning inside the cabinet 20
- Routine maintenance and regular checks 20
- Access condensing unit 21
- Cleaning condensing unit 21
- External cleaning operations 21
- Any work conducted on the equipment must involve disconnection from the power socket and in any case none of the protective elements grid casing should be removed by non qualifi ed staff the equipment must absolutely not be operated when these protective elements have been removed 22
- Maintenance 22
- Special 22
- The person responsible for the equipment is required to have maintenance performed on the equipment according to the frequency indicated in the table below contacting the authorised technical assistance when necessary 22
- Faults 23
- In the event of uncertain or no operation before requesting the intervention of the service technical after sales carry out the following controls 23
- Technical assistance 23
- List of alarms on electronic controlle 24
- Warranty terms and conditions 24
- Annexes 25
- Isetta 25
- Annex 1 26
- Isetta 26
- Annex 2 27
- Isetta 27
- Annex 3 28
- Isetta 28
- Annex 4 29
- Isetta 29
- Annex 5 30
- Isetta 30
- Annex 6 31
- Declaration of conformity 31
- Isetta 31
- Product 31
- Serial number 31
- Via del lavoro 5 06083 bastia umbra pg 31
- We isa s r l 31
- Pagina 1 32
Похожие устройства
- ISA Fiji 4 Инструкция по эксплуатации
- ISA Fiji 7 Инструкция по эксплуатации
- ISA Isabella 13 A LX Инструкция по эксплуатации
- ISA Fiji 140 Инструкция по эксплуатации
- ISA Isetta LX 9R TP Инструкция по эксплуатации
- ISA Isetta LX 6R TP Инструкция по эксплуатации
- ISA Fiji 9 Инструкция по эксплуатации
- ISA Isetta LX 12R TP Инструкция по эксплуатации
- ISA Isetta 4 TP STD Инструкция по эксплуатации
- ISA Fiji 120 Инструкция по эксплуатации
- Lainox CVE024S+LD25 Инструкция по эксплуатации
- Lainox CVE024S+LD25 Руководство по монтажу
- Lainox CVE024S+LD25 Инструкция по технике безопасности (англ.)
- Lainox CVE024S+LD25 Конструкция (англ.)
- Lainox CVE024S+LD25 Электрическая схема
- ISA Isetta 7R TP STD Инструкция по эксплуатации
- Faema E 91 Ambassador SE S/3 Инструкция по эксплуатации
- Faema E 91 Ambassador SE A/2 Инструкция по эксплуатации
- Faema E 91 Ambassador SE A/3 Инструкция по эксплуатации
- Sagi KUA2A (внутренний агрегат) Инструкция по эксплуатации