it is damaged.
6、If the above items are normal, the electric control
board should be replaced.
E5
PG motor
display at
off state
flicker 5/7
SEC
display
at off
state
no feedback
signal of indoor
fan
1、Check whether two sets of plugs on the outlet end of
the motor have loosed from the socket of the
electric control board, insert it firmly when loosing.
2、Check whether the indoor motor has damaged, the
motor should be replaced when it is damaged
3、 Check whether the controllable silicon and other
components on the electric control board have
damaged, replace the controllable silicon or electric
control board when they are damaged.
E6
PG motor
display at
off state
flicker 6/8
SEC
display
at off
state
no over zero
signal
1、Firstly check whether the indoor fan is normal.
2、Check whether the signal outputting from the
integrated chip of the electric control board is
normal, the electric control board should be
replaced when the signal is abnormal.
E7
display at
off state
flicker 7/9
SEC
display
at off
state
outdoor
feedback fault
1、Check whether the winding resistance and operation
current of the compressor are normal
2、Check whether the high and low pressure is normal
when the unit is running.
3、Check whether the indoor and outdoor wiring is
right; when it is wrong, connect them again
according to the circuit diagram
4、 Check whether the contact of the inserter on the
circuit board and the connection are well, otherwise
repair.
5、Check whether the signal feedback wire is
disconnected, replace or connect the feedback
signal wire.
6、Check whether the supply power is phase-lacking or
phase opposition.
7、Check whether the AC electromagnetic contactor is
well.
E8
display at
off state
flicker 8/10
SEC
display
at off
state
frost
protection/over
heat protection
1、Check whether the filter of the indoor unit is dirty or
blocked, and clean if it is dirty.
2、Check whether the indoor fan is running normally,
and replace the motor if it is abnormal.
3、Check whether indoor pipe temperature sensor is
normal, and replace the sensor if it is abnormal.
4、Check whether the system pressure is normal, if
abnormal, should check whether there is leakage,
and fill the refrigerant again.
Содержание
Похожие устройства
- Chigo CS/CU-25H3A-V84 Каталог Chigo 2011
- Chigo CS/CU-61H3A-P84 Инструкция по эксплуатации
- Chigo CS/CU-61H3A-P84 Сертификат
- Chigo CS/CU-61H3A-P84 Коды ошибок
- Chigo CS/CU-61H3A-P84 Каталог Chigo 2011
- Chigo CS/CU-21H3A-V84 Инструкция по эксплуатации
- Chigo CS/CU-21H3A-V84 Сертификат
- Chigo CS/CU-21H3A-V84 Коды ошибок
- Chigo CS/CU-21H3A-V84 Каталог Chigo 2011
- Rix I/O-W12S Инструкция по эксплуатации
- Rix I/O-W12S Инструкция по монтажу
- Rix I/O-W18S Инструкция по эксплуатации
- Chigo CS/CU-51H3A-P84 Инструкция по эксплуатации
- Chigo CS/CU-51H3A-P84 Сертификат
- Chigo CS/CU-51H3A-P84 Коды ошибок
- Chigo CS/CU-51H3A-P84 Каталог Chigo 2011
- Rix I/O-W09S Инструкция по эксплуатации
- Rix I/O-W09S Инструкция по монтажу
- Chigo CS/CU-32H3A-V84 Инструкция по эксплуатации
- Chigo CS/CU-32H3A-V84 Сертификат
Скачать
Случайные обсуждения