Daikin FVQ125C / RZQSG125L8Y1 [10/18] A left and right direction
![Daikin FVQ125C / RZQSG125L8Y1 [10/18] A left and right direction](/views2/1327752/page10/bga.png)
6 English
DEFROST OPERATION (Frost removal oper-
ation for the outdoor unit)
• As the frost on the coil of an outdoor unit increase,
heating effect decreases and the system goes
into DEFROST OPERATION.
• The indoor unit fan stops and the remote control-
ler display shows “ ”.
The remote controller displays the airflow rate
that is set.
• After 6 to 8 minutes (maximum 10 minutes) of
DEFROST OPERATION, the system returns to
HEATING OPERATION.
• When the operation is switched to the HEATING
OPERATION during or after the DEFROST
OPERATION, white mist comes out from the air
outlet of the outdoor unit.
(Refer to “VI.” on page 11.)
• A hissing and “Shuh” sound may be heard during
this particular operation.
Regarding outside air temperature and heat-
ing capacity
• The heating capacity of the air conditioner
declines as the outside air temperature falls. In
such a case, use the air conditioner in combina-
tion with other heating systems.
NOTE
• When a combustion appliance is used, ventilate
the room regularly.
•
Do not use the combustion appliance where the air
from the air conditioner is blown directly toward it.
• When the warm air stays under the ceiling and
your feet are cold, we recommend that you use a
circulator (a fan to circulate the air inside the
room). For details, consult your dealer.
• When the indoor temperature exceeds the set
temperature, the air conditioner discharges a
gentle breeze (switches to whisper mode). (The
remote controller displays the airflow rate that are
being set.)
[CHARACTERISTICS OF THE PROGRAM
DRY OPERATION]
• This operation lowers the humidity without lower-
ing the indoor temperature, and automatically
sets the airflow rate and temperature. Therefore,
the remote controller does not display the airflow
rate and set temperature. (The indoor tempera-
ture detected when the operation button is
pressed is the set temperature.)
When the indoor temperature is lowered, air dis-
charge from the air conditioner may stop.
• If the PROGRAM DRY OPERATION is used
when the indoor temperature is low, frost forms
on the heat exchanger of the indoor unit. In this
case, the system automatically switches to
DEFROST OPERATION for a while.
NOTE
• If the temperature is excessively lowered, switch
to the COOLING OPERATION once, and then
stop the operation. When the temperature
increases to a suitable level, start the PROGRAM
DRY OPERATION again.
Note: The PROGRAM DRY OPERATION cannot
be used when the indoor temperature is
20°C or lower.
AIRFLOW DIRECTION ADJUST
There are 2 ways of adjusting the airflow direction.
A. Left and right direction
Press the AIRFLOW DIRECTION ADJUST
button to select the air direction as follow-
ing.
The AIRFLOW FLAP display
swings as shown below and the
airflow direction continuously
varies. (Automatic swing set-
ting)
Press AIRFLOW DIRECTION
ADJUST button to select the air
direction of your choice.
The AIRFLOW FLAP display
stops swinging and the airflow
direction is fixed. (Fixed airflow
direction setting)
A. Left and right direction
(Remote controller)
B. Up and down direction
(by hand)
swing
UntitledBook1.book Page 6 Wednesday, December 14, 2011 4:14 PM
Содержание
- Floor standing type 1
- Fvq71cveb fvq100cveb fvq125cveb fvq140cveb 1
- Operation manual 1
- Split system air conditioner 1
- Bertaraf gereksinimleri 4
- Disposal requirements 4
- Disposal requirements vorschriften zur entsorgung instructions d élimination requisitos para la eliminación specifiche di smaltimento προ ÿ ποθεσεισ απορριψησ vereisten voor het opruimen requisitos para a eliminação требования к утилизации bertaraf gereksinimleri 4
- Instructions d élimination 4
- Requisitos para a eliminação 4
- Requisitos para la eliminación 4
- Specifiche di smaltimento 4
- Vereisten voor het opruimen 4
- Vorschriften zur entsorgung 4
- Προϋποθέσεις απόρριψης 4
- Требования к утилизации 4
- Contents 5
- Important information regarding the refrig erant used 5
- Indoor unit 5
- Names and functions of parts 5
- Outdoor unit 5
- Precautions for group control system or two remote controller control system 5
- What to do before opera tion 5
- What to do before operation 5
- Safety precautions 6
- Due to high voltage do not open control box lid for ten minutes after the safety breaker is switched off 8
- Operation range 8
- At the start of operation and after defrosting operation 9
- Characteristics of the cooling operation cooling operation and automatic cooling operation 9
- Characteristics of the heating operation heating operation and automatic heating operation 9
- If drain piping is not carried out properly dirt and debris may be accumulated in the drain pipe and cause water leakage if it occurs stop the air con ditioner and consult with you dealer for assistance 9
- Installation site 9
- Low airflow rate is used prevent humidity increase 9
- Operation characteris tics 9
- Operation characteristics 9
- Operation procedure 9
- Pay attention to running noises too 9
- Regarding drainage of drain piping 9
- Regarding wiring 9
- Start of operation 9
- A left and right direction 10
- A left and right direction remote controller 10
- Airflow direction adjust 10
- B up and down direction by hand 10
- Characteristics of the program dry operation 10
- Defrost operation frost removal oper ation for the outdoor unit 10
- Press the airflow direction adjust button to select the air direction as follow ing 10
- Regarding outside air temperature and heat ing capacity 10
- There are 2 ways of adjusting the airflow direction 10
- Adjusting up and down airflow by hand 11
- B up and down direction 11
- Group no 11
- Horizontal flaps 11
- How to adjusting up and down air flow 11
- Interlocking flaps for group no 2 11
- Interlocking flaps for group no 4 11
- Lower flaps 11
- Movement of left and right airflow flaps 11
- Optimum operation 11
- The group no is stamped on the top and back of each flap 11
- Upper flaps 11
- Upward blow 11
- Vertical blow 11
- How to clean the air filter 12
- Maintenance for service personnel 12
- Air filter 13
- Filter guide 13
- How to clean air outlet suction grille exterior and remote con troller 13
- Suction grille 13
- Cleaning before and after sea sonal use start up after a long stop 14
- Not a malfunction of the air conditioner 14
- Not a malfunction of theair conditioner 14
- What to do to stop the system for a long period 14
- Power circuit breaker earth leakage breaker 16
- Trip position 16
- Trouble shooting 16
- Indoor unit no in which a malfunction occurs 17
- Inspection display 17
- Malfunction code 17
- Operation lamp 17
- P170549 14j em11a037 18
Похожие устройства
- Daikin FVQ125C / RZQSG125L8Y1 Схема
- Daikin FVQ125C / RZQSG125L8Y1 Каталог оборудования Daikin
- Daikin FUQ100C / RZQG100L9V1 Инструкция по эксплуатации
- Daikin FUQ100C / RZQG100L9V1 Схема
- Daikin FUQ100C / RZQG100L9V1 Каталог оборудования Daikin
- Daikin FUQ125C / RZQG125L8Y1 Инструкция по эксплуатации
- Daikin FUQ125C / RZQG125L8Y1 Схема
- Daikin FUQ125C / RZQG125L8Y1 Каталог оборудования Daikin
- Daikin FUQ71C / RZQG71L9V1 Инструкция по эксплуатации
- Daikin FUQ71C / RZQG71L9V1 Схема
- Daikin FUQ71C / RZQG71L9V1 Каталог оборудования Daikin
- Daikin FUQ125C / RZQG125L9V1 Инструкция по эксплуатации
- Daikin FUQ125C / RZQG125L9V1 Схема
- Daikin FUQ125C / RZQG125L9V1 Каталог оборудования Daikin
- Daikin FVQ100C / RZQSG100L9V1 Инструкция по эксплуатации
- Daikin FVQ100C / RZQSG100L9V1 Схема
- Daikin FVQ100C / RZQSG100L9V1 Каталог оборудования Daikin
- Abat ПКА 6-1/3П Инструкция по эксплуатации
- Abat ПКА 6-1/3П Паспорт Abat ПКА 6-1/3П
- Abat ПКА 6-1/3П Руководство по установке и подключению ПКА