Daikin FVQ125C / RZQSG125L8Y1 [12/18] How to clean the air filter
![Daikin FVQ125C / RZQSG125L8Y1 [12/18] How to clean the air filter](/views2/1327752/page12/bgc.png)
8 English
• Adjust the room temperature properly for a com-
fortable environment. Avoid excessive heating or
cooling.
Not doing so wastes electricity.
• When the display shows “ ”, ask a qualified
service person to clean the filters.
(Refer to “MAINTENANCE” on page 8.)
Operating the unit with stained air filter may
decrease capacity or cause malfunction.
• Install TVs, radios, and stereos 1 m or more away
from the indoor unit and remote controller.
Images may become fuzzy and noise may be
generated.
• Turn off the power circuit breaker when it is not in
use for a long period. When the main power switch
is turned on, small amount of power is consumed
even if the system is not in operation. (*1) Turn off
the power circuit breaker for saving energy. When
reoperating, turn on the power circuit breaker 6
hours before operation for smooth running.
(Refer to “MAINTENANCE” on page 8.) (*2)
*1 The consumed power while the outdoor unit is
not in operation depends on the model.
*2 The setting before the power circuit breaker is
cut off is stored. (The timer setting is cleared.)
• Fully use the function of airflow direction adjust.
Cold air gathers on the floor, and warm air gathers
in the ceiling.
Set the air discharge to horizontal direction during
COOLING or PROGRAM DRY OPERATION, and
set it downwards during HEATING OPERATION.
Do not let the air blow directly to a person.
• Use the TIMER OPERATION effectively.
It takes some time until the indoor temperature
reaches the set temperature. It is advisable to
start operation in advance using TIMER OPERA-
TION.
ONLY A QUALIFIED SERVICE PERSON IS
ALLOWED TO PERFORM MAINTENANCE
WARNING
• Do not use flammable gases (such as hair or
insect sprays) near the indoor unit.
Do not wipe the indoor unit with benzene or thin-
ner.
This may cause cracking, electric shock, or fire.
CAUTION
• Do not wash the air conditioner with water
Doing so may result in an electric shock and fire.
• To clean the air conditioner, be sure to stop oper-
ation, and turn the power circuit breaker off. It may
cause electric shock or injury.
NOTE
• Do not remove the air filter except for during
cleaning. Doing so may damage the unit.
• Do not install anything (such as kitchen paper)
other than the approved air filters on the air inlet.
Doing so may lower operation efficiency and
cause freezing or leakage.
HOW TO CLEAN THE AIR FILTER
Clean the air filter when the display shows “ ” on
the remote controller (TIME TO CLEAN AIR FIL-
TER).
• The display shows after a certain period of oper-
ation.
NOTE
• The time until the display appears can be
changed. For information on using the air condi-
tioner in a dirty place, contact your dealer.
• Once the staining on the air filter cannot be
removed, replace the filter with a new one.
(The air filter for replacement is provided as an
optional part.)
• Do not use the air conditioner in an oily environ-
ment. If oil adheres, clean the air filter and suction
grille regularly.
8. MAINTENANCE
(FOR SERVICE PERSONNEL)
Stain
Time until display
appears
Standard
2,500 hours
(approx. 1 year)
When the amount of
staining is large
1,250 hours
(approx. a half year)
UntitledBook1.book Page 8 Wednesday, December 14, 2011 4:14 PM
Содержание
- Floor standing type 1
- Fvq71cveb fvq100cveb fvq125cveb fvq140cveb 1
- Operation manual 1
- Split system air conditioner 1
- Bertaraf gereksinimleri 4
- Disposal requirements 4
- Disposal requirements vorschriften zur entsorgung instructions d élimination requisitos para la eliminación specifiche di smaltimento προ ÿ ποθεσεισ απορριψησ vereisten voor het opruimen requisitos para a eliminação требования к утилизации bertaraf gereksinimleri 4
- Instructions d élimination 4
- Requisitos para a eliminação 4
- Requisitos para la eliminación 4
- Specifiche di smaltimento 4
- Vereisten voor het opruimen 4
- Vorschriften zur entsorgung 4
- Προϋποθέσεις απόρριψης 4
- Требования к утилизации 4
- Contents 5
- Important information regarding the refrig erant used 5
- Indoor unit 5
- Names and functions of parts 5
- Outdoor unit 5
- Precautions for group control system or two remote controller control system 5
- What to do before opera tion 5
- What to do before operation 5
- Safety precautions 6
- Due to high voltage do not open control box lid for ten minutes after the safety breaker is switched off 8
- Operation range 8
- At the start of operation and after defrosting operation 9
- Characteristics of the cooling operation cooling operation and automatic cooling operation 9
- Characteristics of the heating operation heating operation and automatic heating operation 9
- If drain piping is not carried out properly dirt and debris may be accumulated in the drain pipe and cause water leakage if it occurs stop the air con ditioner and consult with you dealer for assistance 9
- Installation site 9
- Low airflow rate is used prevent humidity increase 9
- Operation characteris tics 9
- Operation characteristics 9
- Operation procedure 9
- Pay attention to running noises too 9
- Regarding drainage of drain piping 9
- Regarding wiring 9
- Start of operation 9
- A left and right direction 10
- A left and right direction remote controller 10
- Airflow direction adjust 10
- B up and down direction by hand 10
- Characteristics of the program dry operation 10
- Defrost operation frost removal oper ation for the outdoor unit 10
- Press the airflow direction adjust button to select the air direction as follow ing 10
- Regarding outside air temperature and heat ing capacity 10
- There are 2 ways of adjusting the airflow direction 10
- Adjusting up and down airflow by hand 11
- B up and down direction 11
- Group no 11
- Horizontal flaps 11
- How to adjusting up and down air flow 11
- Interlocking flaps for group no 2 11
- Interlocking flaps for group no 4 11
- Lower flaps 11
- Movement of left and right airflow flaps 11
- Optimum operation 11
- The group no is stamped on the top and back of each flap 11
- Upper flaps 11
- Upward blow 11
- Vertical blow 11
- How to clean the air filter 12
- Maintenance for service personnel 12
- Air filter 13
- Filter guide 13
- How to clean air outlet suction grille exterior and remote con troller 13
- Suction grille 13
- Cleaning before and after sea sonal use start up after a long stop 14
- Not a malfunction of the air conditioner 14
- Not a malfunction of theair conditioner 14
- What to do to stop the system for a long period 14
- Power circuit breaker earth leakage breaker 16
- Trip position 16
- Trouble shooting 16
- Indoor unit no in which a malfunction occurs 17
- Inspection display 17
- Malfunction code 17
- Operation lamp 17
- P170549 14j em11a037 18
Похожие устройства
- Daikin FVQ125C / RZQSG125L8Y1 Схема
- Daikin FVQ125C / RZQSG125L8Y1 Каталог оборудования Daikin
- Daikin FUQ100C / RZQG100L9V1 Инструкция по эксплуатации
- Daikin FUQ100C / RZQG100L9V1 Схема
- Daikin FUQ100C / RZQG100L9V1 Каталог оборудования Daikin
- Daikin FUQ125C / RZQG125L8Y1 Инструкция по эксплуатации
- Daikin FUQ125C / RZQG125L8Y1 Схема
- Daikin FUQ125C / RZQG125L8Y1 Каталог оборудования Daikin
- Daikin FUQ71C / RZQG71L9V1 Инструкция по эксплуатации
- Daikin FUQ71C / RZQG71L9V1 Схема
- Daikin FUQ71C / RZQG71L9V1 Каталог оборудования Daikin
- Daikin FUQ125C / RZQG125L9V1 Инструкция по эксплуатации
- Daikin FUQ125C / RZQG125L9V1 Схема
- Daikin FUQ125C / RZQG125L9V1 Каталог оборудования Daikin
- Daikin FVQ100C / RZQSG100L9V1 Инструкция по эксплуатации
- Daikin FVQ100C / RZQSG100L9V1 Схема
- Daikin FVQ100C / RZQSG100L9V1 Каталог оборудования Daikin
- Abat ПКА 6-1/3П Инструкция по эксплуатации
- Abat ПКА 6-1/3П Паспорт Abat ПКА 6-1/3П
- Abat ПКА 6-1/3П Руководство по установке и подключению ПКА