Mitsubishi Electric PCA-RP140KAQ / PUHZ-P140YHA [8/32] Electrical work
![Mitsubishi Electric PCA-RP71KAQ / SUZ-KA71VA [8/32] Electrical work](/views2/1331075/page8/bg8.png)
8
6. Electrical work
Simultaneous twin/triple/quadruple system
S1
S2
L
N
1
2
L
N
S1
S2
S3
1
2
L
N
S1
S2
S3
1
2
L
N
S1
S2
S3
1
2
L
N
S1
S2
S3
S3
AB C
D
E
JBC
F
H
GGGG
K
K
K
H
H
H
ON
OFF 1 2
(SW8)
3
S1
S2
S3
L
N
BLUE
BLUE
YELLOW
YELLOW
CN01
CN01
BLACK
CN01
BLACK
S1
S2
S3
L
N
YELLOW
BLUE
BLUE
YELLOW
CN01
* Affi x label B that is included with the manuals near each wiring diagram for the indoor and outdoor units.
If the indoor and outdoor units have separate power supplies, refer to the table
below. If the indoor power supply terminal kit is used, change the indoor unit elec-
trical box wiring refering to the fi gure in the right and the DIP switch settings of the
outdoor unit control board.
Indoor unit specifi cations
Indoor power supply terminal kit (option) Required
Indoor unit electrical box connector connec-
tion change
Required
Label affixed near each wiring diagram for
the indoor and outdoor units
Required
Outdoor unit DIP switch settings (when us-
ing separate indoor unit/outdoor unit power
supplies only)
* There are 3 types of labels (labels A, B and C). Affi x the appropriate labels to the
units according to the wiring method.
Indoor unit model PCA
*1. A breaker with at least 3.0 mm contact separation in each pole shall be pro-
vided. Use earth leakage breaker (NV).
The breaker shall be provided to ensure disconnection of all active phase
conductors of the supply.
*2. Max. 120 m
*3. The 10 m wire is attached in the remote controller accessory. Max. 500 m
*4. The fi gures are NOT always against the ground.
Indoor unit power supply ~/N (single), 50 Hz, 230 V
Indoor unit input capacity
Main switch (Breaker)
*1 16 A
Wiring
Wire No. ×
size (mm²)
Indoor unit power supply & earth 3 × Min. 1.5
Indoor unit-Outdoor unit *2 2 × Min. 0.3
Indoor unit-Outdoor unit earth –
Remote controller-Indoor unit *3 2 × 0.3 (Non-polar)
Circuit
rating
Indoor unit L-N *4 AC 230 V
Indoor unit-Outdoor unit S1-S2 *4 –
Indoor unit-Outdoor unit S2-S3 *4 DC24 V
Remote controller-Indoor unit *4 DC12 V
Notes: 1. Wiring size must comply with the applicable local and national code.
2.
Power supply cords and indoor unit/outdoor unit connecting cords shall not be lighter than polychloroprene sheathed fl exible cord. (Design 60245 IEC 57)
3. Install an earth longer than other cables.
A Outdoor unit power supply
B Earth leakage breaker
C Wiring circuit breaker or isolating switch
D Outdoor unit
E Indoor unit/outdoor unit connecting cables
F Remote controller
G Indoor unit
H Option
J Indoor unit power supply
K Indoor unit earth
Never splice the power cable or the indoor-outdoor connection cable, otherwise it may result in a smoke, a fi re or communication failure.
Warning:
* The indoor power supply terminal kits are required.
Set the SW8-3 to ON.
Option
Option
Indoor unit power supplied from outdoor unit
(initial setting)
Separate indoor unit/outdoor unit power supplies
Connectors (connections of initial setting
are for indoor unit power supplied from
outdoor unit)
If the indoor and
outdoor units have
separate power
supplies, change the
connections of the
connectors as shown
in the following
fi gure.
Connectors
Indoor unit
control board
Indoor unit
control board
Содержание
- Air conditioners кондиционеры 1
- Installatiehandleiding 1
- Installation manual 1
- Installationshandbuch 1
- Installationsmanual 1
- Manual de instalación 1
- Manual de instalação 1
- Manuale di installazione 1
- Manuel d installation 1
- Montaj elki tabi 1
- Εγχειριδιο οδηγιων εγκαταστασησ 1
- Руководство по установке 1
- Before electric work 2
- Before installation environment 2
- Before installation or relocation 2
- Before starting the test run 2
- Contents 2
- Safety precautions 2
- Check the indoor unit accessories fig 3 1 3
- Fig 2 1 3
- Fig 3 1 3
- Fig 3 2 3
- Installation location 3
- Installing the indoor unit 3
- Outline dimensions indoor unit fig 2 1 3
- Outline dimensions outdoor unit 3
- Preparation for installation fig 3 2 3
- Fig 3 3 4
- Fig 3 4 4
- Fig 3 5 4
- Fig 3 6 4
- Installing the indoor unit 4
- Installing the indoor unit fig 3 5 4
- Connecting pipes fig 4 1 5
- Fig 4 1 5
- Fig 4 2 5
- Fig 4 3 5
- For twin triple combination 5
- Indoor unit fig 4 3 5
- Installing the refrigerant piping 5
- Precautions 5
- Drainage piping work 6
- Electric wiring fig 6 1 6
- Electrical work 6
- Fig 5 1 6
- Fig 5 2 6
- Fig 5 3 6
- Fig 6 1 6
- 1 system 7
- Electrical work 7
- Indoor unit power supplied from outdoor unit 7
- Separate indoor unit outdoor unit power supplies for puhz application only 7
- Simultaneous twin triple quadruple system 7
- System 7
- Electrical work 8
- On off 1 2 sw8 3 8
- Simultaneous twin triple quadruple system 8
- Electrical work 9
- Fig 6 2 fig 6 3 9
- Fig 6 4 9
- Remote controller 9
- Electrical work 10
- Fig 6 5 fig 6 6 10
- Fig 6 7 fig 6 8 10
- Fig 6 9 10
- Function setting on the unit selecting the unit functions 10
- Function settings 10
- Electrical work 11
- Fig 6 10 11
- Function setting on the remote controller 11
- Before test run 12
- Fig 7 1 12
- Fig 7 2 12
- Fig 7 3 12
- Fig 7 4 12
- Test run 12
- Using wired remote controller 12
- Fig 7 5 13
- Fig 7 6 13
- Self check 13
- Test run 13
- Test run 14
- Test run 15
- Easy maintenance function 16
- F1 f2 f3 f4 16
- Дренажные трубы 71 6 электрические работы 71 7 выполнение испытания 77 8 функция простого техобслуживания 81 17
- Меры предосторожности 17
- Меры предосторожности 67 2 место установки 68 3 установка внутреннего прибора 68 4 прокладка труб хладагента 70 17
- Перед тестовым прогоном 17
- Перед установкой или перемещением 17
- Перед установкой окружающая среда 17
- Перед электрическими работами 17
- Содержание 17
- Fig 2 1 18
- Fig 3 1 18
- Fig 3 2 18
- Контурные габариты наружный прибор 18
- Место установки 18
- Подготовка к установке fig 3 2 18
- Проверьте наличие дополнительных принадлежностей к внутреннему прибору fig 3 1 18
- Установка внутреннего прибора 18
- Fig 3 3 19
- Fig 3 4 19
- Fig 3 5 19
- Fig 3 6 19
- Установка внутреннего прибора 19
- Установка внутреннего прибора fig 3 5 19
- Fig 4 1 20
- Fig 4 2 20
- Fig 4 3 20
- Внутренний прибор fig 4 3 20
- Для комбинации из двух трех элементов 20
- Меры предосторожности 20
- Прокладка труб хладагента 20
- Соединение труб fig 4 1 20
- Fig 5 1 21
- Fig 5 2 21
- Fig 5 3 21
- Fig 6 1 21
- Дренажные трубы 21
- Электрические работы 21
- Электропроводка fig 6 1 21
- 1 system 22
- System 22
- Одновременная двойная тройная четверная система 22
- Отдельные источники электропитания для внутреннего прибора наружного прибора только для применения puhz 22
- Питание на внутренний прибор подается от наружного прибора 22
- Система 1 1 22
- Электрические работы 22
- G g g g 23
- On off 1 2 sw8 3 23
- Если у внутреннего и наружного приборов различные источники электропитания см таблицу ниже при использовании комплекта клемм источника электропитания внутреннего прибора замените проводку распределительной коробки внутреннего прибора в соответствии с рисунком справа и измените настройки микропереключателя панели управления наружного прибора 23
- Изменение соединения разъема распределительной коробки внутреннего прибора 23
- Одновременная двойная тройная четверная система 23
- Электрические работы 23
- Fig 6 2 fig 6 3 24
- Fig 6 4 24
- Пульт дистанционного управления 24
- Электрические работы 24
- Fig 6 5 fig 6 6 25
- Fig 6 7 fig 6 8 25
- Fig 6 9 25
- Установки функций 25
- Функциональная настройка прибора выбор функций прибора 25
- Электрические работы 25
- Fig 6 10 26
- Функциональная настройка на пульте дистанционного управления 26
- Электрические работы 26
- Fig 7 1 27
- Fig 7 2 27
- Fig 7 3 27
- Fig 7 4 27
- Выполнение испытания 27
- Перед пробным прогоном 27
- Fig 7 5 28
- Fig 7 6 28
- Выполнение испытания 28
- Самодиагностика 28
- Выполнение испытания 29
- Выполнение испытания 30
- F1 f2 f3 f4 31
- Функция простого техобслуживания 31
Похожие устройства
- Mitsubishi Electric PCA-RP100KAQ / PUHZ-P100YHA Руководство по установке
- Mitsubishi Electric PCA-RP100KAQ / PUHZ-P100YHA Инструкция по установке
- Mitsubishi Electric PCA-RP140KAQ / PUHZ-P140VHA Руководство по установке
- Mitsubishi Electric PCA-RP140KAQ / PUHZ-P140VHA Инструкция по установке
- Mitsubishi Electric PCA-RP125KAQ / PUHZ-P125YHA Руководство по установке
- Mitsubishi Electric PCA-RP125KAQ / PUHZ-P125YHA Инструкция по установке
- Mitsubishi Electric PCA-RP125KAQ / PUHZ-P125VHA Руководство по установке
- Mitsubishi Electric PCA-RP125KAQ / PUHZ-P125VHA Инструкция по установке
- Mitsubishi Electric PCA-RP60KAQ / SUZ-KA60VA Руководство по установке
- Mitsubishi Electric PCA-RP60KAQ / SUZ-KA60VA Инструкция по установке
- Liebherr GNP 3056 Инструкция по эксплуатации
- Fagor CO-110 DD Инструкция по эксплуатации
- Mitsubishi Electric PCA-RP71HAQ / PUHZ-ZRP71VHA Руководство по установке
- Mitsubishi Electric PCA-RP71HAQ / PUHZ-ZRP71VHA Инструкция по установке
- Mitsubishi Electric PCA-RP140KAQ / PU-P140YHAR Руководство по установке
- Mitsubishi Electric PCA-RP140KAQ / PU-P140YHAR Инструкция по установке
- Mitsubishi Electric PCA-RP71KAQ / PU-P71VHAR Руководство по установке
- Mitsubishi Electric PCA-RP71KAQ / PU-P71VHAR Инструкция по установке
- Smeg KSE60X3 Руководство по эксплуатации
- Mitsubishi Electric PCA-RP100KAQ / PU-P100YHAR Руководство по установке