5 Applied Control and Functions
(Including Circuit Configuration)
5-1. Indoor controller block diagram
5-1-1. When main (sub) remote controller connected
<Compact 4-way cassette type, 1-way cassette (SH) type, ceiling type, concealed duct
standard type, slim duct type>
Main (sub) remote controller (up to 2 units)
Main remote controller
:RBC-AMT32E
Sub remote controller
:RBC-AS21E2
Schedule Timer (Weekly timer mode)
Display
LCD
Display
LED
EEPROM
Remote controller
communication circuit
Function setting
Power
supply
circuit
Rechargeable
battery
Display
LCD
LCD
driver
Function setting
Key switch
Key switch
CPU
Power
supply
circuit
Indoor unit
Central
remote
controller
(optional)
Network adaptor (optional)
Indoor control P.C. board (MCC-1402)
(In case
of 1:1
model)
Network
adaptor P.C.
board
(MCC-1401)
Remote controller
communication
circuit
AI-NET
communication
circuit
Power supply circuit
Switch setting
Transformer
Louver
motor
Indoor
fan
motor
*Not applicable to concealed duct
standard type Slim Duct Type
Drain
pump
Power supply circuit
Fan motor
control circuit
In operation
Alarm
Getting ready
Thermostat ON
COOL
HEAT
FAN
AC
synchronization
signal input circuit
BUS
communication
circuit
External output
Driver
TA sensor
TCI sensor
TC2 sensor
TCJ sensor
Float input
Remote
controller
communication
circuit
EEPROM
Network adaptor : "1:1 model" connection interface
TCB-PCNT30TLE2
Indoor / outdoor communication
Power source
1Ø 220-240 V, 50 Hz
1Ø 220 V, 60 Hz
Outdoor
unit
Sameas left
*2
Sameas left
*2
Power
source
Up to 8 units can be connected.
*1
*1 Only up to 7 units if a network
adaptor is installed with 2
main (sub) remote controllers
connected.
*2 The network adaptor can only
be installed in one unit.
*3 A weekly timer cannot be
connected to a sub remote
controller.
Power
source
Outdoor
unit
Outdoor
unit