5-1-3. When both main (sub) remote controller and wireless
remote controller kit connected
<Compact 4-way cassette type, 1-way cassette (SH) type, ceiling type, concealed duct
standard type, slim duct type>
Main (sub) remote controller (up to 2 units)
Main remote controller
:RBC-AMT32E
Sub remote controller
:RBC-AS21E2
Schedule Timer (Weekly timer mode)
Display
LCD
Display
LED
EEPROM
Remote controller
communication circuit
Function setting
Power
supply
circuit
Rechargeable
battery
Display
LCD
LCD
driver
Function setting
Key switch
Key switch
Power
supply
circuit
Indoor unit
Central
remote
controller
(optional)
Network adaptor (optional)
Indoor control P.C. board (MCC-1402)
(In case
of 1:1
model)
Network
adaptor P.C.
board
(MCC-1401)
Remote controller
communication
circuit
AI-NET
communication
circuit
Power supply circuit
Switch setting
Transformer
Louver
motor
Indoor
fan
motor
*Not applicable to concealed duct
standard type Slim Duct Type
Drain
pump
Power supply circuit
Fan motor
control circuit
In operation
Alarm
Getting ready
Thermostat ON
COOL
HEAT
FAN
AC
synchronization
signal input circuit
BUS
communication
circuit
External output
Driver
TA sensor
TCI sensor
TC2 sensor
TCJ sensor
Float input
Remote
controller
communication
circuit
EEPROM
Network adaptor : "1:1 model" connection interface
TCB-PCNT30TLE2
Indoor / outdoor communication
Power source
1Ø 220-240 V, 50 Hz
1Ø 220 V, 60 Hz
Outdoor
unit
Sameas left
*2
Sameas left
*2
Power
source
Up to 8 units can be
connected. *1
*1 Only up to 7 units
if a network
adaptor is
installed.
*2 The network
adaptor can only
be installed in
one unit.
*3 A weekly timer
cannot be
connected to a
sub remote
controller.
Power
source
Outdoor
unit
Outdoor
unit
Sensor P.C. board
Power supply
circuit
Wireless remote controller kit
Remote controller
communication
circuit
Emergency
operation SW
Function
setting SW
Display LED
Sensor circuit
Buzzer
*Not applicable to concealed