•  With the unit at the time of ring, there may be smoke if you installed a ventilation system creates a vacuum in the room
where the appliance is located, this applies to most rooms equipped with a mechanical extraction system VMC (such as the
kitchen, etc.)
•  Ensure that the air required for burning can be taken in sucient quantities from the room where the stove is installed. If
the structure of the building is such that the amount of air is too small to provide oxidation and ventilation should be provided
for the installation of additional air supply.


The ash must be removed when it is necessary. Excess ash obstructs air ow, which is needed for combustion, and can cause
hearth overheating and even damage.. Ashes should be place into a metal container equipped with a tight lid. The container should
be placed on non-ammable surface away from ammable materials until completely cool.

Cleaning the glass should be done when the replace is warm. On the market there are many cleaning solvents to remove
debris. Refer to the owner’s manual. Do not use abrasive cleaners. The door is always closed with a handle.

When wood burns slowly is formed a black carbon containing organic substances which react with water vapor that is emitted
by the wood, thereby, the walls of the chimney when cold precipitate forms creosote. If the sediment is formed ame lights up with
a very high temperature. Regularly check the build-up of creosote on it to determine the frequency of cleaning the chimney. Please
note that the combustion is more intense the build-up of creosote is less.

The glass in the frame should not be too tight. After installation must be possible to move the glass in the frame. This is
necessary because the glass and metal have dierent coecients of thermal expansion and too tightly attached window has been
destroyed.


The maximal temperature of the continuous heating is about 800 ° C. The average temperature in the replace operates on
the glass is about 450 ° C. This leaves a very large available reserves and crack windows can not be caused by overheating

Too infrequent cleaning of the chimney or burning of wet wood, may result in chimney re caused by inammation of creosote
(inammable substance emitted when wet wood is burned). Distinctive symptoms of the chimney re are: smell of the ue gas (soot)
in the building, alarming, previously unheard sounds in the chimney, a large increase of the chimney temperature, sparks or ames
coming out from the chimney.

•  immediately call the Fire Brigade
•  extinguish the re in the replace as much as possible, using sand or soil
•  do not extinguish the re with water, since the rapid cooling of the chimney and evaporation of water can cause cracks and
spread of the re
•  cut o the chimney air supply – close the door, close the primary air intake and secondary air intake (if possible)
•  Once the re is extinguished, chimney sweep company should carry out an inspection of chimney technical condition,
before you light the re in the replace again.

  
Issue with setting
a re. Flame
extinguishes.
Too much moisture in wood Use wood that moisture content not exceeds 20% (seasoned wood for 2
years in a covered and well-ventilated place).
Too thick wood logs When setting a re, use small pieces of wood. To maintain the re use
splintered logs.
No air supply Increase air supply by opening the air intake diaphragm.
Insucient chimney air draft Check if the ue gas damper is not closed (open in case it is closed).
Arrange an inspection of chimney ue to check if there is no leakage or if
the ue is not clogged (clean if needed).
!