ISA Pastryshow 120 A [11/32] Coolant

ISA Pastryshow 120 A [11/32] Coolant
11
EN
PASTRYSHOW 2
USE AND MAINTENANCE MANUAL
428000514037
COOLANT DESCRIPTION
R290 coolant is an environmentally compatible gas, but it is highly
ammable.
Be very carefully during transport, installation of the equipment and disposal
to avoid damage to the coolant circuit pipes.
IF DAMAGE OCCURS:
Keep the equipment far from ames or sources of ignition. Properly ventilate
the premises for a few minutes. Turn the unit off, pull the plug. Inform
customer service. The more coolant an appliance contains, the bigger the
room must be where the appliance is installed. In areas that are too small, a
leak can create a ammable mixture of air and gas. The volume of the room
where the equipment is located must be at least 19 m³ for each chiller
system present.
ATTENTION
Maintenance must be performed by quali ed personnel who have been trained
and authorised to work with ammable coolants.
R600a coolant is an environmentally compatible gas, but it is highly
ammable.
Be very carefully during transport, installation of the equipment and disposal
to avoid damage to the coolant circuit pipes.
IF DAMAGE OCCURS:
Keep the equipment far from ames or sources of ignition. Properly ventilate
the premises for a few minutes. Turn the unit off, pull the plug. Inform
customer service. The more coolant an appliance contains, the bigger the
room must be where the appliance is installed. In areas that are too small, a
leak can create a ammable mixture of air and gas. The volume of the room
where the equipment is located must be at least 17 m³ for each chiller
system present.
ATTENTION
Maintenance must be performed by quali ed personnel who have been trained
and authorised to work with ammable coolants.
R744 coolant is an environmentally compatible gas.
Be very carefully during transport, installation of the equipment and disposal
to avoid damage to the coolant circuit pipes.
IF DAMAGE OCCURS:
Keep the equipment far from ames or sources of ignition. Properly ventilate
the premises for a few minutes. Turn the unit off, pull the plug. Inform
customer service.
ATTENTION
The cooling system is a High Pressure system.
Do not tamper with the system; call a trained
and quali ed technician before dismantling.
Maintenance must only be performed
by quali ed personnel.
6.13 COOLANTS (where applicable)