6. SAFETY
The equipment is fi tted with safety devices. Purchaser must instruct the user to staff about the risks, the
safety devices and the general rules regarding safety provided for by the legislation of the country where the
equipment is installed. Users / operators must be aware of the position and operation of all controls and of
the equipment characteristics; they shall also have fully read this manual.
6.1 SAFETY DEVICES PRESENT
Devices whose operation prevents the occurrence of risk situations in operating conditions (e.g. fuses,
pressure switches, protections, magnet circuit breakers, etc.).
6.2 FIXED PROTECTIONS
Fixed protective devices consist of fi xed perimeter shields, which are used to prevent external parts
from entering the equipment.
Danger
It is prohibited to re-start the appliance following maintenance without having correctly restores the
panels.
Visual Check
You should check the integrity of fi xed panels and corresponding fi xings to the frame, focussing in
particular on the protective panels.
6.3 ISOLATING THE ELECTRIC POWER SUPPLY
Before conducting any maintenance work on the equipment or part of it, it is necessary to section the
power supply that powers it.
Danger
In the event of maintenance operations in which the operator cannot prevent accidental closure of
the circuit by others, to totally disconnect the appliance from the mains electricity.
6.4 RESIDUAL RISKS
During design the manufacturer examined all the areas or parts at risk. Therefore, all necessary
precautions have been taken to prevent risks to persons and damage to the appliance.
Attention
Periodically check that all safety devices are operating correctly.
Do not remove the fi xed guards.
Do not introduce objects or tools into the work area.
Although the appliance is fi tted with the safety devices prepared, there are still some risks that
cannot be eliminated, but reduced via corrective actions by the fi nal integrator and correct operational
procedures.
Below is a summary of the risks that remain in the equipment in the following stages:
• Normal operation
• Adjusting and set up
• Maintenance
• Cleaning
6.5 RISKS OF CONTACT WITH LIVE PARTS
Risk of breaking or damaging the electrical components of the appliance, with a possible reduction in
safety levels, following a short circuit.
Before connecting the electricity supply, make sure there is no ongoing maintenance work.
Attention
Before making the connection, check that the d.c. current in the installation point does not exceed
that indicated on the protections switches present in the electric control board. If this is not the case,
the user must envision the relevant limiting devices.
It is strictly forbidden to conduct any electrical modifi cation, in order to prevent additional unforeseen
hazards and risks.
Содержание
- Progel 1
- Attachment 3
- The manual contains symbols to attract the reader s attention and highlight particularly important aspects the table below illustrates the meaning of the various symbols used 3
- Wiring diagram 412100767100 37 3
- Wiring diagram 412100769300 38 3
- Isa s r l 10
- Manufacturer 10
- Warranty terms and conditions 10
- Www isaitaly com 10
- Equipment identification 11
- Composition 12
- Product blast chilling and freezing 12
- Load of products 13
- Load unloading of products 13
- No yes 13
- Yes no 13
- Yes no 14
- Using the spike temperature probe 15
- Pre cooling 16
- Preservation 16
- Temperature 16
- Use of the lamp uv optional 16
- Fixed protections 17
- Isolating the electric power supply 17
- Residual risks 17
- Risks of contact with live parts 17
- Safety 17
- Safety devices present 17
- Circuit faults 18
- Explosive atmosphere 18
- Falling objects 18
- Slipping 18
- Tripping 18
- Warning sign 18
- Cooling 19
- Foodstuffs safety 19
- Disposa 20
- Disposal of waste material 20
- Procedure for disposal and recycling at the end of appliance life spa 20
- Electric connection 21
- Installation 21
- Installation positioning environmental conditions 21
- Storage and unpacking 21
- After all maintenance it is mandatory to perform all electric safety tests in agreement with the iec en 50106 standard 22
- Attention 22
- Maintenance 22
- The staff in charge of the appliance must control and respect the expiry dates for maintenance given in the table below calling the authorised technical after sales assistance when indicated 22
- Faults technical after sales assistance 23
- If the appliance is not working properly or stops working before contacting the customer support centre check the following 23
- Alarms lis 24
- Technical specifications 25
- 037 use and maintenance manual 26
- Containers arrangement 26
- Kit supports ice cream 27
- 037 use and maintenance manual 28
- Kit supports ice cream 28
- Kit supports ice cream 29
- Installation 30
- Load limits 30
- Positioning levelling 31
- Control panel 32
- Start up 32
- User interface 32
- Cleaning 33
- External 33
- Internal 33
- Cleaning 34
- Condensing unit 34
- Defrost water collection tra 34
- Cleaning 35
- Seal door 35
- Prolonged appliance switch off 36
- Pagina 1 39
- Pagina 1 40
Похожие устройства
- La Nordica Doroty Инструкция по эксплуатации
- La Nordica Doroty Технический паспорт
- La Nordica Doroty Декларация о соответствии (англ.)
- La Nordica Doroty Декларация о соответствии (англ.)
- ISA Alfa 130 RV TN Small Инструкция по эксплуатации
- Gemlux GL-WB-8G Инструкция по эксплуатации
- Gemlux GL-WB-8G Каталог оборудования Gemlux
- La Nordica Teodora Инструкция по эксплуатации
- La Nordica Teodora Технический паспорт
- La Nordica Teodora Декларация о соответствии (англ.)
- La Nordica Teodora Декларация о соответствии (англ.)
- ISA Alfa 130 RV TN Инструкция по эксплуатации
- ISA Thea 110 RV TN Инструкция по эксплуатации
- ISA Thea 140 RV TN Инструкция по эксплуатации
- La Nordica Viviana Инструкция по эксплуатации
- La Nordica Viviana Технический паспорт
- La Nordica Viviana Декларация о соответствии (англ.)
- La Nordica Viviana Декларация о соответствии (англ.)
- ISA Action 100 RV TB/TN Инструкция по эксплуатации
- La Nordica Viviana Plus Инструкция по эксплуатации