ISA Zero T12 VT SP [21/40] Electric connection
![ISA Zero T12 VT SP [21/40] Electric connection](/views2/1335877/page21/bg15.png)
EN
USE AND MAINTENANCE MANUAL
428000730
037
21
ZERO PROGEL
8. INSTALLATION
This manual supplies the information necessary for correct unpacking, procedures for
positioning and connection to mains electricity.
8.1 STORAGE AND UNPACKING
The appliance, with or without the packaging, should be carefully stored inside warehouses or in areas
away from the elements and direct sunlight, at a temperature between 0 and +40 °C.
The appliance should only be moved by qualifi ed personnel operating
forklift trucks, the power of which should be suited to handling the weight
of the product.
During said operation the appliance MUST placed on the special pallet supplied.
Unpack the appliance by removing the screws fi xing it to the pallet.
All packaging materials are recyclable and should be disposed of in accordance with local regulations.
Please destroy "plastic" bags to prevent them from becoming hazardous to children (suffocation).
8.2 INSTALLATION - POSITIONING - ENVIRONMENTAL CONDITIONS
Attention
A dry room that can be ventilated is the suitable location for the appliance's installation.
There should be a good air fl ow around the compressor/condensing unit.
Therefore the area around the unit should not be obstructed by boxes or other objects.
Position the appliance away from heat sources (radiators, stoves of all types, etc.) and away from
the effects of continuous currents of air (e.g. caused by fans, air conditioning vents, etc.).
If it is unavoidable to install near a heat source, use a suitable insulating plate,
Also avoid exposure to direct sunlight; all of this causes the temperature inside the refrigerated
compartment to rise with negative consequences on operation and energy consumption.
Do not use the appliance outdoors and do not leave it exposed to rain.
8.3 ELECTRIC CONNECTION
Attention
Check that the network voltage matches the one displayed on the identifi cation plate of the
appliance, and that the power is adequate.
Check on the socket that the power supply voltage provides rated voltage (±10%) when you start
up the compressor.
The plug should be directly connected to the electrical socket.
It is forbidden to connect the plug to the socket by means of multiple socket extensions or
adaptors.
The plant power supply socket must be fi tted with a disconnection device from the mains electricity
(dimensioned to the load and in compliance with Standards in force), which guarantees complete
disconnection in category III (3) over-voltage conditions and therefore protects the circuits against
earth faults, overloads and short circuits.
Do not route the electricity cable in passageways.
Attention
Earthing is necessary and mandatory by law.
Содержание
- Progel 1
- Attachment 3
- The manual contains symbols to attract the reader s attention and highlight particularly important aspects the table below illustrates the meaning of the various symbols used 3
- Wiring diagram 412100767100 37 3
- Wiring diagram 412100769300 38 3
- Isa s r l 10
- Manufacturer 10
- Warranty terms and conditions 10
- Www isaitaly com 10
- Equipment identification 11
- Composition 12
- Product blast chilling and freezing 12
- Load of products 13
- Load unloading of products 13
- No yes 13
- Yes no 13
- Yes no 14
- Using the spike temperature probe 15
- Pre cooling 16
- Preservation 16
- Temperature 16
- Use of the lamp uv optional 16
- Fixed protections 17
- Isolating the electric power supply 17
- Residual risks 17
- Risks of contact with live parts 17
- Safety 17
- Safety devices present 17
- Circuit faults 18
- Explosive atmosphere 18
- Falling objects 18
- Slipping 18
- Tripping 18
- Warning sign 18
- Cooling 19
- Foodstuffs safety 19
- Disposa 20
- Disposal of waste material 20
- Procedure for disposal and recycling at the end of appliance life spa 20
- Electric connection 21
- Installation 21
- Installation positioning environmental conditions 21
- Storage and unpacking 21
- After all maintenance it is mandatory to perform all electric safety tests in agreement with the iec en 50106 standard 22
- Attention 22
- Maintenance 22
- The staff in charge of the appliance must control and respect the expiry dates for maintenance given in the table below calling the authorised technical after sales assistance when indicated 22
- Faults technical after sales assistance 23
- If the appliance is not working properly or stops working before contacting the customer support centre check the following 23
- Alarms lis 24
- Technical specifications 25
- 037 use and maintenance manual 26
- Containers arrangement 26
- Kit supports ice cream 27
- 037 use and maintenance manual 28
- Kit supports ice cream 28
- Kit supports ice cream 29
- Installation 30
- Load limits 30
- Positioning levelling 31
- Control panel 32
- Start up 32
- User interface 32
- Cleaning 33
- External 33
- Internal 33
- Cleaning 34
- Condensing unit 34
- Defrost water collection tra 34
- Cleaning 35
- Seal door 35
- Prolonged appliance switch off 36
- Pagina 1 39
- Pagina 1 40
Похожие устройства
- La Nordica Doroty Инструкция по эксплуатации
- La Nordica Doroty Технический паспорт
- La Nordica Doroty Декларация о соответствии (англ.)
- La Nordica Doroty Декларация о соответствии (англ.)
- ISA Alfa 130 RV TN Small Инструкция по эксплуатации
- Gemlux GL-WB-8G Инструкция по эксплуатации
- Gemlux GL-WB-8G Каталог оборудования Gemlux
- La Nordica Teodora Инструкция по эксплуатации
- La Nordica Teodora Технический паспорт
- La Nordica Teodora Декларация о соответствии (англ.)
- La Nordica Teodora Декларация о соответствии (англ.)
- ISA Alfa 130 RV TN Инструкция по эксплуатации
- ISA Thea 110 RV TN Инструкция по эксплуатации
- ISA Thea 140 RV TN Инструкция по эксплуатации
- La Nordica Viviana Инструкция по эксплуатации
- La Nordica Viviana Технический паспорт
- La Nordica Viviana Декларация о соответствии (англ.)
- La Nordica Viviana Декларация о соответствии (англ.)
- ISA Action 100 RV TB/TN Инструкция по эксплуатации
- La Nordica Viviana Plus Инструкция по эксплуатации