USE AND MAINTENANCE MANUAL
428000487237
8. INSTALLATION
This manual supplies the information necessary for correct unpacking, procedures for
positioning and connection to mains electricity.
8.1 STORAGE and UNPACKING
The appliance, with or without the packaging, should be carefully stored inside warehouses or in areas
away from the elements and direct sunlight, at a temperature between 00 and +40 °C.
The appliance should only be moved by quali ed personnel operating forklift trucks, the power of which
should be suited to handling the weight of the product: when performing this task,
the appliance MUST be placed on the special pallet supplied.
Unpack the appliance by removing the screws xing it to the pallet.
All packaging materials are recyclable and should be disposed of in accordance with local regulations.
Please destroy "plastic" bags to prevent them from becoming hazardous to children (suffocation).
8.2 INSTALLATION - POSITIONING - ENVIRONMENTAL CONDITIONS
Attention
Suitable for installation in a dry, well ventilated room. There should be a good air ow around the
compressor and condensing unit. Therefore the area around the unit should not be obstructed by
boxes or other objects.
Position the appliance away from heat sources (radiators, stoves of all types, etc.) and away from
the effects of continuous currents of air (e.g. caused by fans, air conditioning vents, etc.). If it is
unavoidable to install near a heat source, use a suitable insulating plate,
Also avoid exposure to direct sunlight; all of this causes the temperature inside the refrigerated
compartment to rise with negative consequences on operation and energy consumption. Do not use
the appliance outdoors and do not leave it exposed to rain.
8.3 ELECTRICAL CONNECTION
Attention
Check that the network voltage matches the one displayed on the identi cation plate of the
appliance, and that the required power is adequate.
Check on the socket that the power supply voltage provides rated voltage (±10%) when you start
up the compressor.
The plug should be directly connected to the electrical socket. It is forbidden to connect the plug to
the socket by means of multiple socket extensions or adaptors.
The plant power supply socket must be tted with a disconnection device from the mains electricity
(dimensioned to the load and in compliance with Standards in force), which guarantees complete
disconnection in category III (3) over-voltage conditions and therefore protects the circuits against
earth faults, overloads and short circuits.
Do not route the electricity cable in passageways.
Attention
Earthing is necessary and mandatory by law.