ISA Alfa 130 RV TN Small [14/34] Routine

ISA Alfa 130 RV TN Small [14/34] Routine
14
ALFA
USE AND MAINTENANCE MANUAL
428000487237
EN
OPERATION FREQUENCY
MAINTENANCE
EXTRAORDINARY
AUTHORISED
PERSONNEL
Cleaning the external surfaces Depending upon Use and Necessity
X
User
Cleaning the accessible internal parts
(without the use of tools)
Depending upon Use and Necessity
X
User
Control power supply cable,
plugs and/or electric sockets
Monthly
Every 6 months
X
User
Check integrity of sealing gaskets Monthly
X
User
Cleaning the defrosting water water collection
tray
Every 6 months
Depending upon use and necessity
X
Technical
Assistance
Condenser cleaning Monthly
Every 6 months
X
Technical
Assistance
Check the compressor oil level
(whenever present)
Every 6 months
X
Technical
Assistance
Air tank draining
(whenever present)
Every 6 months
X
Technical
Assistance
Check pneumatic connections
(whenever present)
Every 6 months
X
Technical
Assistance
Check the integrity of chiller system piping Every 6 months
X
Technical
Assistance
Inspect cables and internal power connections Every 6 months
X
Technical
Assistance
Cleaning condensate drying sponges
(whenever present)
Every 6 months
X
Technical
Assistance
Lamp / LED replacement (if present)
X
Technical
Assistance
Control panel replacement (ECU - thermal switch - etc.)
X
Technical
Assistance
Power cable, plug and/or socket replacement
X
Technical
Assistance
9. ROUTINE
The Staff in charge of the appliance must control and respect the expiry dates for maintenance, given in the table
below, calling the authorised Technical After-sales assistance when indicated.
Attention
After all maintenance it is mandatory to perform all electric safety tests in agreement with the IEC
EN 50106 Standard.