Beko CSG 52120 GX [15/96] Flow rate adjustment screw

Содержание

1 2 3 4 Flame failure device model dependant Spark plug Injector Burner 1 Flow rate adjustment screw P IUnless there is an abnormal condition do I J Jnot attempt to remove the gas burner taps IoYou must call an Authorised service agent if it is necessary to change the taps Reduced gas flow rate setting for hob taps 1 Ignite the burner that is to be adjusted and turn the knob to the reduced position 2 Remove the knob from the gas tap 3 Use an appropriately sized screwdriver to adjust the flow rate adjustment screw For LPG Butane Propane turn the screw clockwise For the natural gas you should turn the screw counter clockwiseonce The normal length of a straight flame in the reduced position should be 6 7 mm 4 If the flame is higher than the desired position turn the screw clockwise If it is smaller turn anticlockwise 5 For the last control bring the burner both to high flame and reduced positions and check whether the flame is on or off Depending on the type of gas tap used in your appliance the adjustment screw position may vary 1 Flow rate adjustment screw Exchange of injector for the grill 1 Open the front door 2 Unscrew the screw of grill burner 3 Slightly pull the grill burner 1 to lift it free with its link s on the rear side connected 4 Unscrew injector by turning to counter clockwise direction 1 2 3 Grill burner Injector holder Injector Exchange of injector for the oven 1 Unscrew fastening screws of the back wall 15 EN