HansGrohe Logis 71313000 [4/80] Assembly see page 31

HansGrohe Logis 71313000 [4/80] Assembly see page 31
Assembly see page 31
Spare parts (see page 38)
Cleaning (see page 37) and en-
closed brochure
Maintenance check valve (see
page 44)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Operation (see page 41)
Flow diagram
(see page 36)
Hand shower
Bath Spout
Dimensions (see page 35)
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
The plumbing codes applicable in the respective
countries must be oberserved.
Technical Data
Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure: 1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 80°C
Recommended hot water temp.: 65°C
Thermal disinfection: max. 70°C / 4 min
Safety against backflow
The product is exclusively designed for drinking water!