AXIS P1346/-E/AXIS P1347/-E - About
Configuration
From the drop-down lists, select the size and level of information to be added to the System Log and Access Log files.
The default information level for the Access Log is set to Critical & Warnings, i.e. failed connections. However, in an error
situation and when requesting support, set it to the highest information level Critical & Warnings & Info.
For the Log Level for Email, select from the drop-down list the level of information to send as email and enter the destination
email address.
Advanced
Scripting
Scripting is an advanced function that enables you to customize and use scripts. This function is a very powerful tool.
Caution!
Improper use may cause unexpected behavior or even cause loss of contact with the unit. If a script does cause problems,
reset the unit to its factory default settings. A backup file may be of use to return the unit to its latest configuration.
Axis strongly recommends that you do not use this function unless you understand the consequences. Note that Axis
support does not provide assistance for problems with customized scripts.
For more information, please visit the Video developer pages at www.axis.com/developer
File Upload
Files (e.g. web pages and images) can be upload to the network camera and used as custom settings. Uploaded files are
accessed through http;//<ip address>/local/<user>/<file name> where <user> is the selected user access group (viewer,
operator or administrator) for the uploaded file.
Plain Config
Plain Config is for the advanced user with experience of Axis network camera configuration. All parameters can be set and
modified from this page. Help is available from the standard help pages.
About
Here you can find basic information about your network camera. You can also view third party software licenses.
Resetting to Factory Default Settings
To reset the camera to the original factory default settings, go to the System Options > Maintenance web page (as described
in Maintenance, on page 45) or use the Control button on the side of the camera (see page 5) as described below:
Using the Control Button
This will reset all parameters, including the IP address and the focus position, to the factory default settings:
1. Disconnect power from the camera.
2. Press and hold the Control button and reconnect power.
3. Keep the Control button pressed until the Status indicator color changes to amber (this may take up to 15 seconds).
4. Release the Control button. When the Status indicator changes to green (which may take up to 1 minute), the process
is complete and the camera has been reset. The unit now has the default IP address 192.168.0.90
5. Re-assign the IP address, for instructions see the Installation Guide supplied with the camera.
6. Refocus the camera, for instructions see the Installation Guide supplied with the camera.