Bosch GLL 3-50 Professional (0.601.063.800) [13/239] Technical data

Bosch GLL 3-50 Professional (0.601.063.800) [13/239] Technical data
English | 13
Bosch Power Tools 1 618 C00 99J | (11.10.13)
Technical Data
Product Features
The numbering of the product features shown refers to the il-
lustration of the measuring tool on the graphic page.
1 Exit opening for laser beam
2 Pulse-function indicator
3 Pulse-function button
4 Operating mode button
5 Battery indicator
6 Tripod mount 1/4"
7 Battery compartment
8 Battery lid
9 Polarity identification
10 Latch of battery lid
11 Tripod mount 5/8"
12 Laser warning label
13 Serial number
14 On/Off switch
15 Guide groove
16 Guide rail
17 Locking screw for extendable stand
18 Handwheel
19 Rotating platform
20 Magnets
21 Laser target plate
22 Construction tripod BS 150*
23 Laser viewing glasses*
24 Universal holder BM 1*
25 Telescopic rod BT 350*
26 Measuring plate with stand*
27 Laser receiver*
28 Holder*
29 Case*
* The accessories illustrated or described are not included as
standard delivery.
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the meas-
uring tool.
To open the battery lid 8, pull latch 10 and fold the battery lid
out. Insert the batteries. When inserting, pay attention to the
correct polarity according to the representation on the out-
side of the battery lid.
When the battery indication 5 flashes red, the batteries must
be replaced.
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
Remove the batteries from the measuring tool when
not using it for extended periods. When storing for ex-
tended periods, the batteries can corrode and self-dis-
charge.
Using the Rotating Platform
Place the measuring tool with the
guide groove 15 on the guide rail 16
of the rotating platform 19 and slide
the measuring tool to the stop onto
the platform. To disconnect, pull the
measuring tool in the opposite direc-
tion from the rotating platform.
Cross-line Laser GLL 3-50
Article number
3 601 K63 8..
Working range
1)
–standard
with laser receiver
m
m
10
5–50
Levelling Accuracy
mm/m ±0.3
Perpendicular point working
range
m5
Perpendicular point accuracy
mm/m ±0.6
Self-levelling range, typically
°±4
Levelling duration, typically
s< 4
Operating temperature
°C 10... +40
Storage temperature
°C 20 ... +70
Relative air humidity, max.
%90
Laser class
2
Laser type
nm
mW
635
< 1
C
6
1
Shortest pulse duration
s1/1600
Tripod mount
"
"
1/4
5/8
Batteries
4x1.5VLR6(AA)
Operating time, min.
h6
Automatic switch-off
after approx.
min 30
Weight according to
EPTA-Procedure 01/2003
kg 0.9
Dimensions
without rotating platform
with rotating platform
mm
mm
146 x 83 x 117
Ø 201 x 197
Degree of protection
IP 54*
1) The working range can be decreased by unfavourable environmental
conditions (e.g. direct sun irradiation).
* dust and splash proof
Please observe the article number on the type plate of your measuring
tool. The trade names of the individual measuring tools may vary.
The measuring tool can be clearly identified with the serial number 13
on the type plate.
OBJ_BUCH-1973-002.book Page 13 Friday, October 11, 2013 11:17 AM