1. Description and connection
The heating cables should be connected to a 230V, 50Hz electric network. Degree of protection: IP67.
ADSV cables have protective braiding. The cable's protective braiding meets the standards required of
metal grid or metal shield and provides increased protections in spaces where that is required
(bathroom, laundry, etc.) The protective braiding is to be connected to the PE conductor or to a
protective grounding connection.
2. Use for floor heating in residential buildings, houses, workshops,
and restrooms
If the floor heating is intended to be used to warm the floor surface for short intervals, we recommend
that the heating cable be installed close to the floor surface within the upper limit of the recommended
outputs W/m
2
.
If a room is to be heated, it is necessary to know the building’s heat loss value in order to make the
correct choice of heating system. The installed wattage should then correspond to 1.2 to 1.4 times the
calculated heat loss. However, if this amount exceeds the maximum permitted wattage per square
metre (see the TABLE), additional heating must be used (e.g. ECOFLEX or ATLANTIC convectors).
RECOMMENDED AND MAXIMUM OUTPUTS
When cables are to be installed under tiles into the adhesive sealing cement, the space between them
should not be more than 100 mm or less than 40 mm.
INSTALLATION UNDER FLOOR TILES INTO ADHESIVE
SEALING CEMENT, SO-CALLED THIN-LAYER FLOORS
Please read first the General Terms and Conditions.
To allow for expansion around the periphery of the room between the baseboards and the floor tiles,
use an expansion profile or fill the spaces with silicone sealing cement.
FLOOR COVERING
ROOM
RECOMMENE
DED FLAT
OUTPUT
W/m
2
MAXIMUM
FLAT OUTPUT
W/m
2
RECOMMENEDED
LENGHT OUTPUT
W/m
POZNÁMKA
FLOOR TILES
80 - 120
200
10
Temperature of floor surface in rooms
occupied for long time periods may
not exceed 27°C.
FLOOR TILES IN
BATHROOM
120 -160
250
15
FLOOR TILES IN
BATHROOM
160 - 200
300
18