Biasi Parva Control 24SV Инструкция по эксплуатации онлайн [15/30] 338186
![Biasi Parva Control 24SV Инструкция по эксплуатации онлайн [15/30] 338186](/views2/1403878/page15/bgf.png)
Содержание
- Iiiihiiiihihiiiiiiih 1
- Zh biasi 1
- Maintenance 5
- Описание котла 5
- Calibrate the gas valve according to the 6
- Conversion kit indicating the type of gas and the gas pressures to which the appliance has been set 6
- Extract the control panel as explained 6
- Gas conversion 6
- Gas supply используемый газ 6
- Hand side panel and the front panel of the case 6
- Heating output required see section 6 in this manual 6
- In accordance with the following table 6
- In the section 5 1 of this manual 6
- Instructions given in the section 6 6
- Loosen the screws a and remove the 6
- Natural gas метан l p g сжиженый газ 6
- Of the combustion chamber and the removable case of the sealed chamber 6
- Panel adjacent to the data badge the self adhesive label included with the 6
- Position of dip switch n положение переключателя n 2 on вкл off выкл 6
- Re assemble the burner the front panel 6
- Replace the service panel the left 6
- Service panel fig 7 6
- Set correctly the dip switch 2 fig 7 6
- Set the correct gas pressure for central 6
- Stick on the inside of the left hand side 6
- Table of contents 6
- Выберите правильное давление для 6
- Герметичной камеры 6
- Извлеките панель управления как описано в разделе 5 1 настоящего руководства 6
- Калибруйте газовый клапан в 6
- Левой боковой панели расположив 6
- Мощности см раздел 6 настоящего руководства 6
- Наклейку поставлется с 6
- Ослабьте винты а и снимите сервисную панель рис 7 6
- Панель левую боковую панель и 6
- Переднюю панель корпуса 6
- Переключатель 2 рис 7 в 6
- Правильно установите 6
- Преобразовательным комлектом с 6
- Приведенными в разделе 6 6
- Приклейте с внутренней стороны 6
- Рядом с табличкой с данными 6
- Содержание 6
- Соответствии с инструкциями 6
- Соответствии со следующей 6
- Таблицей 6
- Требуемой выходной тепловой 6
- Указанием типа газа и давлением на которое был настроен котел 6
- Установите на место горелку переднюю панель камеры сгорания и сьемную переднюю часть 6
- Установите на место сервисную 6
- Gas conversion 7 выбор газа 1 appliance description 1 описание устройства 7
- Air flue exhaust sampling points 8
- Точки отбора всасываемого воздуха и отвода отходящих газов 8
- О о о 9
- Ойй 9
- Instruction for use 10
- Инструкция no 10
- Эксплуатации 10
- Useful advice 3 полезные советы 6 commissioning 6 ввод в эксплуатацию 16
- Technical information 4 техническая информация 20
- Installation 30
- Монтаж 30
Похожие устройства
- Biasi Parva Control 24SV Технические характеристики
- Biasi Parva Control 24SV Сертификат
- Biasi Parva Control 32SV Инструкция по эксплуатации
- Alphatherm Beta ATE 100 Инструкция по эксплуатации
- Alphatherm Beta ATE 100 Буклет
- Biasi Parva Control 32SV Технические характеристики
- Biasi Parva Control 32SV Сертификат
- Biasi Nova Parva 24A Инструкция по эксплуатации
- Biasi Nova Parva 24A Технические характеристики
- Biasi Nova Parva 24A Сертификат
- Biasi Nova Parva 28A Инструкция по эксплуатации
- Biasi Nova Parva 28A Технические характеристики
- Biasi Nova Parva 28A Сертификат
- Biasi Nova Parva 24S Инструкция по эксплуатации
- Biasi Nova Parva 24S Технические характеристики
- Biasi Nova Parva 24S Сертификат
- Biasi Nova Parva 28S Инструкция по эксплуатации
- Biasi Nova Parva 28S Технические характеристики
- Biasi Nova Parva 28S Сертификат
- Biasi Nova Parva 32S Инструкция по эксплуатации
Commissioning Instruction for use 4 Open the C h circuit filling valve 12 in Fig 6 1 and fill the C h circuit see section 2 2 on page 5 4 5 Open each radiator air release tap starting with the lower point and close it only when clear water free of bubbles flows out 5 6 Purge the air from the pump by unscrewing the pump plug 20 Fig 6 2 release the pump by turning the rotor in the direction indicated by the arrow on the information plate 6 Откройте впускной клапан 12 системы отопления на рис 6 1 и заполните систему см раздел 2 2 на стр 5 Откройте спускные краны на всех радиаторах начиная с нижней точки и закройте их когда из них пойдет чистая без пузырьков вода Спустите воздух из насоса открутив винт 20 рис 6 2 разблокируйте насос поворачивая ротор в направлении указанном стрелкой информационной табличке R g 2 9 на 7 Close the pump plug 7 Заверните винт насоса 8 Continue filling the system The actual reading should ideally be 1 3 bar and not less than 0 3 bar 8 9 Close all air release valves on the C h system 9 10 Inspect the boiler and the system for water soundness and remedy any leaks discovered 10 Проверьте котел и систему на шум и устраните течи в случае их обнаружения 11 Cold flush the system to remove any loose particles and any system debris before starting the boiler for the first time 11 6 4 Lighting the boiler 6 4 Запуск котла Some products incorporate an anti cycling time delay It is normal when first switching the boiler on for the boiler to operate on heating for a few seconds then switch off After 3 4 minutes has elapsed the boiler will then re ignite and operate perfectly normally The ignition delay cycle does not prevent normal operation of the boiler to provide D h w Некоторые котлы оборудованы антициклической задержкой времени Это нормальное явление когда котел включается на отопление на несколько секунд и затем выключается По истечении 3 4 минут котел включится автоматически и продолжит нормальную работу Задержка включения не влияет на нормальную работу котла на приготовление горячей воды Если котел оснащен внешними устройствами управления напр программатором комнатным термостатом убедитесь что они работают в режиме запрос тепла 1 Включите питание котла на автомате Индикатор работы котла 9 будет моргать каждые 4 сек If external controls are fitted e g Timeclock room thermostat ensure they call for heat 1 Turn on the electricity supply to the boiler switching on the fused spur isolation switch he appliance operation light 9 will flash every 4 seconds 2 Turn the function selector 7 as in Fig 6 3 The appliance operation light 9 will flash every 2 seconds 40 2 Продолжайте заполнение системы Идеальный показатель должен быть 1 3 бара и не менее 0 3 бара Закройте все спускники системе отопления воздуха в Промойте холодную систему чтобы удалить из нее частицы мусора и окалины прежде чем запустить котел в первый раз When you expect not to use the boiler for a long period 1 Switch off the electricity supply to the boiler by means of the fused spur isolation switch Если Вы собираетесь не использовать котел в течение длительного периода времени 1 Отключите котел от сети 2 Shut off the gas supply cock 13 and the cocks for the water circuits fitted under the boiler Fig 2 10 2 3 3 Empty the water circuits if necessary as shown in the installation instructions in the section maintenance Перекройте кран подачи газа 13 и краны водяных контуров расположенные под котлом рис 2 10 Опорожните системы отопления горячей воды если это необходимо как указано в инструкции по монтажу в разделе обслуживание Closed position положение закрыто Fig 2 10 Переместете переключатель 7 в положение как указано на рис 6 3 Индикатор работы котла 9 будет моргать каждые 2 секунды 9