Trotec SP 1500 [34/51] Sp 500

Trotec SP 500 [34/51] Sp 500
SP 500
Version 2.0 © TROTEC Produktions- u. Vertriebs GmbH
34 / 51
Technical changes reserved Freilingerstraße 99, A-4614 Marchtrenk
www.troteclaser.com
14
“Shift” for 2
nd
function key leve
l
For additional Operations. When this key is pressed together with the following keys, the func-
tions indicated are activated:
Exhaust (5): Air assist on/off
Positioning keys X/Y/Z (2): These keys drive the laser head to
the end position
15
Used to manually switch the exhaust system on and off.
The key illumination shows the status of the exhaust system. When the key is illuminated, the
exhaust system is switched on.
After completing the engraving process, the exhaust system can only be switched off after
some seconds (follow-up time).
Air assist is switched on/off by simultaneously pressing these keys:
“Shift” for 2nd function key level (14)
And
Exhaust on/off (9)
16
17
Positioning keys Z
When pressing one of these two keys the working table moves in Z direction (up-
wards or downwards).
Use these positioning keys to move the table manually.
When both keys are pressed simultaneously, the material is focused automatically.
Before the autofocus- move is started, the head is moved backward in line with the light barri-
ers. If the light barrier is broken, e.g. by an air assist nozzle, the upward move will be sup-
pressed to prevent a collision between the nozzle and the table.
The Autofocus option might not work on transparent materials or materials which
are not flat.
Bear in mind that defects from head crashes (working head hits material or working
table) are NOT warranted.
By pressing the "Shift" key and a Z- positioning key an automatic move to the corresponding
end- positions is performed:
Shift + Down: the table moves down to the lowest possible position
Shift + Up: the table moves up to the autofocus- position.
Note: Shift + Up will cause the head moving backwards to the light barriers (according simulta-
neous pressing of both z-keys).
If any of positioning keys X and Y is pressed, no moves in Z are possible.
An automatic move of the Z- axis can be stopped by pressing of the positioning keys
(1 or 2).