Airwell Westherm 55 [15/16] Maintenance
![Airwell Westherm 55 [15/16] Maintenance](/views2/1408117/page15/bgf.png)
Page 14
10.4 - Electrical Connections
Re-tighten periodically the electrical connections.
10.5 - Water Piping System
Once a year, drain the piping system and check the furring-up of
the pipes.
10.3 - Fan-Motor Assembly
There is no particular maintenance on fan motor assembly.
However, during periodic maintenance, check that fan wheel rotates
freely without any friction.
10 - Maintenance
It is recommended to proceed to the following maintenance works
in order to ensure a good operation of the unit.
Before performing any maintenance operation, disconnect the
unit main power supply.
10.1 - Air Filter (optional)
Filters should be frequently cleaned to avoid clogging. They should
be inspected every 3 or 4 months under normal operating
conditions and be replaced if necessary (see drawings below for
the filter removal).
10.2 - Coils
Check that coil fins are not clogged or damaged.
To avoid mouldiness of coils caused by an accumulation of fine
dusts, it is recommended to clean them frequently. If necessary,
comb the coil fins with an appropriate tool.
Care must be taken not to damage the fins while cleaning them.
Caution
a 500
e x e
a x a
a
E
a x a
120
a x a
f x f
f1 x f1
VAL arrangement - Filter removal
VAF arrangement - The filter box E allows filter removal
from one of the four sides.
9 - Preliminary Checks Before Start-up
1. Make sure that system piping has been cleaned and all the air
has been purged, before starting up the unit.
2. Ensure that air filter (optional) is clean and properly installed.
3. Make certain that fan rotates freely.
4. Make sure that all water and electrical connections are properly
tightened.
It is not the manufacturer's policy to make recommendations
in terms of water treatment (please contact a specialised
water treatment company).
However, given the critical nature of this subject, particular
care should be taken to ensure that, if treatment is required,
it works effectively.
Using untreated or unsuitable water leads to excessive
clogging inside the coil tubes (earth and mud deposits,
corrosion, etc.) with major consequences on the thermal
efficiency of the unit and irreversible damage to the equipment.
The manufacturer and its representative decline all
responsability in the event of untreated or incorrectly treated
water being used.
If the water pipes are exposed to temperatures below 0 °C,
take the necessary precautions (draining, antifreeze, etc.) to
avoid the coils freezing. Adding antifreeze to the circuit reduces
the unit's performance (if necessary, please contact our sales
network).
Caution
Caution
Содержание
- Westherm 35 110 1
- Description p 4 2
- Dimensional data and weight of options p 7 2
- Dimensional data and weight of standard units p 5 2
- Electrical connections p 14 2
- English 2
- Installation p 9 2
- Introduction p 3 2
- Maintenance p 15 2
- Preliminary checks before start up p 15 2
- Safety precautions p 3 2
- Table of contents 2
- Water connections p 12 2
- Caution 3
- Introduction 3
- Safety precautions 3
- The manufacturer warranty will not be applied if all installation instructions stated in this manual have not been followed 3
- Warning 3
- Description 4
- Electrical data 4
- English 4
- Inspection and storage 4
- Operating limits 4
- Standard motor data 4
- Unit in operation with hot water circulation 4
- Diffuser vm 5
- Diffuser vn 5
- Diffuser vr 5
- Dimensional data and weight of standard units 5
- Vertical arrangement 5
- Diffuser hn 6
- Diffuser ho 6
- Diffuser hp 6
- Dimensional data and weight of standard units cont d 6
- English 6
- Horizontal arrangement 6
- Arrangement 1 val arrangement 2 vaf arrangement 3 vak 7
- Arrangement 4 vajf 7
- Arrangement 5 vagk 7
- Arrangement 6 vagjf 7
- Component description 7
- Dimensional data and weight of options 7
- Dimensions 7
- Standard arrangements 7
- Arrangement 10 vabdf 8
- Arrangement 11 habgz 8
- Arrangement 12 habcgz 8
- Arrangement 7 vagz 8
- Arrangement 8 vabgz arrangement 9 vabf 8
- Dimensional data and weight of options cont d 8
- English 8
- Position of damper control shaft 8
- Standard arrangements 8
- Installation 9
- Unit handling 6 installation location 9
- Warning 9
- English 10
- Installation cont d 10
- Installation instructions 10
- Warning 10
- 55 fan speed 11
- C 10 c 15 c 20 c 30 c 11
- Correction factor 11
- Factor 1 8 1 0 0 0 0 0 0 0 11
- For other temperature differences use the correction factor 11
- Installation cont d 11
- Supply air throw m 11
- Supply diffuser for a supply air temperature difference of 15 c 11
- Temp difference 11
- The air throw allows the units to be installed in the room 11
- The air throw of a propeller fan unit heater is the distance between the unit and the points where the air velocity is no longer felt by the human body approx 0 m sec 11
- The table below gives the air throw of a unit in relation to model and 11
- Vertical arrangement horizontal arrangement 11
- English 12
- Warning 12
- Water coil connections 12
- Water connections 12
- Water volume in the coils 12
- Water connections cont d 13
- Water pressure drop 13
- Electrical connections 14
- English 14
- Standard wiring diagram 14
- To perform electrical wiring of fan motor please refer to wiring diagram supplied in the motor terminal box 14
- Unit connection 14
- Warning 14
- Air filter optional 15
- Caution 15
- Electrical connections 15
- Fan motor assembly 15
- Maintenance 15
- Page 14 15
- Preliminary checks before start up 15
- Vaf arrangement 15
- Val arrangement 15
- Water piping system 15
- Ace pons industrie 42 cours jean jaurès 17800 pons france 16
Похожие устройства
- Airwell Westherm 55 Технические характеристики
- Airwell Westherm 65 Инструкция по эксплуатации
- Ammari AM-089 R Инструкция по эксплуатации
- Ammari AM-089 L Инструкция по эксплуатации
- Ammari AM-100-80 LOW Инструкция по эксплуатации
- Ammari AM-100-80 Инструкция по эксплуатации
- Airwell Westherm 65 Технические характеристики
- Airwell Westherm 70 Инструкция по эксплуатации
- Ammari AM-A-025-80 Инструкция по эксплуатации
- Airwell Westherm 70 Технические характеристики
- Airwell Westherm 110 Инструкция по эксплуатации
- Airwell Westherm 110 Технические характеристики
- Ammari AM-A-38-80 Инструкция по эксплуатации
- Airwell VH 03 Инструкция по эксплуатации
- Airwell VH 05 Инструкция по эксплуатации
- Airwell VH 07 Инструкция по эксплуатации
- Airwell VH 10 Инструкция по эксплуатации
- Airwell VH 15 Инструкция по эксплуатации
- Airwell VH 18 Инструкция по эксплуатации
- Airwell VH 21 Инструкция по эксплуатации