Airedale UWC 75 [8/42] Ultima water cooled chillers
![Airedale UWC 75 [8/42] Ultima water cooled chillers](/views2/1409533/page8/bg8.png)
ULTIMA WATER COOLED Chillers
Chillers
8
Installation & Maintenance : 903-126 IM E 10/04/A
General Description
OPTIONAL EXTRAS – GENERAL
• Anti Vibration Mounts
• Victaulic Counterpipe Kit
• Flow Switch
Loose Item
• Water Filter
Loose Parts Instructions provided
• Sequence Control
(CAUTION : It is only possible to set up sequencing following
completion of interconnecting communication wiring. Airedale Service can
arrange Sequence setup on request.)
• BMS Interface Card
• Dual Pressure Relief Valve
• Leak Detection Kit (DQ & DSQ Only)
• Electronic Soft Start
Factory Fitted
• Alternative Refrigerant (Outside EU)
• Commissioning
OPTIONAL UNIT COVER
• Chillerguard® Maintenance
For details and a competitive
quotation, contact Airedale Service.
Содержание
- Installation operating maintenance manual 1
- Ultima water cooled 1
- Water cooled chiller 75kw 450kw 1
- About airedale products customer services 2
- Caution 2
- Chillers 2
- Customer services 2
- Spares 2
- Training 2
- Ultima water cooled chillers 2
- Warranty commissioning maintenance 2
- Chillers ultima water cooled 3
- Contents 3
- Caution 4
- Chillers 4
- General statement 4
- Important 4
- Safety 4
- Ultima water cooled chillers 4
- Chillers 5
- Chillers ultima water cooled 5
- Exclusions 5
- General 5
- Procedure 5
- Returns analysis 5
- Warranty 5
- Warranty is only valid in the event that 5
- Ce directive 6
- Chillers 6
- General description 6
- Introduction 6
- Quiet chiller dq 6
- Refrigerants 6
- Standard chiller d 6
- Standard features 6
- Super quiet chiller dsq 6
- Ultima water cooled chillers 6
- Unit identification 6
- Water cooled liquid chiller 6
- Chillers 7
- Chillers ultima water cooled 7
- Controls 7
- Electrical 7
- General description 7
- Optional extras energy saving 7
- Power factor correction 7
- Refrigeration 7
- Standard features 7
- Caution 8
- Chillers 8
- Factory fitted 8
- General description 8
- Loose item 8
- Optional extras general 8
- Optional unit cover 8
- Ultima water cooled chillers 8
- Chillers 9
- Chillers ultima water cooled 9
- Dimensions uwc75 uwc250 except uwc240 9
- Installation data 9
- Victaulic type fitting 9
- Chillers 10
- Dimensions uwc240 uwc450 except uwc250 10
- Installation data 10
- Ultima water cooled chillers 10
- Chillers 11
- Chillers ultima water cooled 11
- Installation data 11
- Point loadings weights centre of gravity c of g 11
- Caution 12
- Chillers 12
- Installation data 12
- Lifting dimensions 12
- Ultima water cooled chillers 12
- Unit lifting 12
- Airedale international air conditioning ltd 13
- Anti vibration mount spring type specification installation instructions 13
- Caution 13
- Change 13
- Components 13
- Date 18 10 05 13
- Dimensions 13
- E mail info airedale com website www airedale com 13
- Installation 13
- Leeds road rawdon leeds ls19 6jy england tel 44 0 113 239 1000 fax 44 0 113 250 7219 13
- Manual affected technical installation 13
- Manual part no 901 108 tm e 02 05 a 13
- Technical update 13
- Ultima ucc uccu 30 450 ultima ucc uccu 30 450 ucfc urac uwc75 450 ufc usc200 750 13
- Anti vibration mounting optional 14
- Caution 14
- Chillers 14
- Chillers ultima water cooled 14
- Installation data 14
- Pad type 14
- Selection installation 14
- Spring type cls 14
- Installation data 15
- Ultima water cooled chillers 15
- Caution 16
- Chillers 16
- Chillers ultima water cooled 16
- Component recommended requirements 16
- Installation data 16
- Standard recommended installation parts supplied by others 16
- Water system 16
- Caution 17
- Chillers 17
- Filling 17
- Installation data 17
- Pressure testing 17
- Ultima water cooled chillers 17
- Water system 17
- Caution 18
- Chillers 18
- Chillers ultima water cooled 18
- Ethylene glycol nominal correction factors 18
- Glycol data 18
- Installation data 18
- Propylene glycol nominal correction factors 18
- Caution 19
- Chillers 19
- Electrical 19
- General 19
- Installation data 19
- Interconnecting wiring 19
- Interlocks protection 19
- Ultima water cooled chillers 19
- Chillers 20
- Chillers ultima water cooled 20
- Electrical data 20
- Installation data 20
- Chillers 21
- Electrical data 21
- Installation data 21
- Ultima water cooled chillers 21
- Chillers 22
- Chillers ultima water cooled 22
- Electrical data 22
- Installation data 22
- Caution 23
- Chillers 23
- Constant supply temperature control 23
- Control scheme features 23
- Controls 23
- Ultima water cooled chillers 23
- Variable supply temperature control 23
- Chillers 24
- Chillers ultima water cooled 24
- Controls 24
- General 24
- Navigation 24
- Operation 24
- Standard keypad display 24
- Standard operating page 24
- Chillers 25
- Controls 25
- Menus listed in sequence 25
- Operation cont 25
- Password protection 25
- Real time clock 25
- Setting up 25
- Standard operating page cont 25
- Technical support 25
- Time zones 25
- Ultima water cooled chillers 25
- Unit on off 25
- Analogue inputs 26
- Analogue outputs 26
- Chillers 26
- Chillers ultima water cooled 26
- Controls 26
- Digital inputs 26
- Digital outputs 26
- Status menu 26
- Viewing unit operating status 26
- Alarm handling 27
- Alarms 27
- Chillers 27
- Common alarms 27
- Compressor status 27
- Controls 27
- Electronic expansion valve failure 27
- Emergency stop 27
- Evaporator flow failure 27
- High liquid pressure 27
- Individual circuit alarms 27
- Low suction pressure 27
- Low supply temperature 27
- Phase rotation 27
- Ultima water cooled chillers 27
- Chillers 28
- Chillers ultima water cooled 28
- Commissioning data 28
- Mechanical data 28
- Oil refrigerant charges oil refrigerant charges 28
- Operating limits 28
- Caution 29
- Chillers 29
- Commissioning data 29
- Evaporator 29
- Ultima water cooled chillers 29
- Waterside pressure drops 29
- Chillers 30
- Chillers ultima water cooled 30
- Commissioning data 30
- Condenser 30
- Waterside pressure drops 30
- Chillers 31
- Commissioning data 31
- Condenser 31
- Ultima water cooled chillers 31
- Waterside pressure drops 31
- Chillers ultima water cooled 32
- Commissioning data 32
- Caution 33
- Chillers 33
- Commissioning procedure 33
- General 33
- Pre commissioning checklist 33
- Record 33
- Ultima water cooled chillers 33
- Chillers 34
- Chillers ultima water cooled 34
- Commissioning procedure 34
- Pre commissioning checklist cont 34
- Record 34
- Caution 35
- Chillers 35
- Commissioning checklist 35
- Commissioning procedure 35
- Record 35
- Ultima water cooled chillers 35
- Caution 36
- Chillers 36
- Chillers ultima water cooled 36
- General maintenance 36
- Maintenance 36
- Chillers 37
- Compressor maintenance 37
- General maintenance cont 37
- Maintenance 37
- Shut down periods 37
- Ultima water cooled chillers 37
- Chillers 38
- Chillers ultima water cooled 38
- Parts identification 38
- Spares 38
- Chillers 39
- Ultima water cooled chillers 39
- Chillers 40
- Chillers ultima water cooled 40
- Head office 41
- International sales offices 41
- Regional sales offices 41
- Airedale departmental contact details 42
- Customer services 42
Похожие устройства
- Airedale UWC 100 Инструкция по эксплуатации
- Airedale UWC 125 Инструкция по эксплуатации
- Airedale UWC 150 Инструкция по эксплуатации
- Airedale UWC 225 Инструкция по эксплуатации
- Airedale UWC 300 Инструкция по эксплуатации
- Airedale UWC 400 Инструкция по эксплуатации
- Airedale UWC 475 Инструкция по эксплуатации
- Acson AWM07F Инструкция по эксплуатации
- Acson AWM10F Инструкция по эксплуатации
- Acson AWM07FR Инструкция по эксплуатации
- Acson ALC07B Инструкция по эксплуатации
- Acson ALC10B Инструкция по эксплуатации
- Acson ALC07BR Инструкция по эксплуатации
- Acson ALC10BR Инструкция по эксплуатации
- Acson AWM15F Инструкция по эксплуатации
- Acson AWM20F Инструкция по эксплуатации
- Acson AWM25F Инструкция по эксплуатации
- Acson AWM15FR Инструкция по эксплуатации
- Acson AWM20FR Инструкция по эксплуатации
- Acson AWM25FR Инструкция по эксплуатации