Bomann gspe 877 [23/30] Figure 8

Bomann gspe 877 [23/30] Figure 8
Di shwa sher must be l evel for pr oper dish ra ck op erat ion a nd wash perform anc e.
Place a spirit level on door and rack track inside the tub as shown to check that the
dishwasher is level.
level the dishwasher by adjusting the three levelling legs individually.
When level the dishwasher, please pay attention not to let the dishwasher tip over.
1
2
3
I llustra tion of feet adjus tment
【】Figure 8
NOTE:
The maximum adjustment
height of the feet is 50 mm.
This ap plia nce must be ear thed. I n the e ven t
of a malf unction or brea kdown, earthi ng wil l
reduce the risk of el ectric sho ck by providing a
path of least resistance for the electric current.
This appli an ce is e quipped w ith a cord ha vin g an
equi pment-ea rthin g co nductor and an ea rthing
plug . T he plug m ust be p lugged int o an ap propriat e
out let t hat is in stal led and earthe d in accor dance
with all local s ta ndards a nd req uiremen ts.
I mpr oper conn ecti on of th e equ ip me nt-
gro und ing con ducto r ca n re sult i n th e ri sk
of an electric shock. C he ck wi th a qu alified
electrici an or service representativ e if you
are i n d oubt w het her the app li an ce is pro perl y
gro und ed. Do n ot mo di fy t he plug p ro vided w ith
theappliance;Ifitisnotfit fortheoutlet.
Havea properoutlet installed bya qualified
electrician.
Ensure the voltage and frequency of the power being corresponds to
those on the rating pl ate. Only insert the p lug into an elec trical socket which i s earthed
prop erly. If th e electr ical so cket to wh ich the a ppl ianc e m ust be co nne ct ed is not
appropriate for the plug , replace the socket, rather than using a adaptors or the like as
th ey coul d ca use ove rhea ti ng a nd bur ns .
Plea se look at th e ra ting lab el t o kn ow th e rat ing volta ge a nd c onnect t he d ishw ash er t o the app ropriat e power s upp ly.
Use the r equi red fuse 10 amp, ti me de lay f use or circui t breake r r ec ommen de d and pro vide separat e circ uit s erv ing
only thi s app lia nce.
For personal safety:
DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE.
DO N OT, UNDERANY C IRCUMS TANCES, CUT OR R EMOVE THE EARTHIN G
CONNECTION FROM THE POWER CORD.
Check level side to side
Spirit leve l
Check l ev e l Fron t to Back