Fubag HOUSE MASTER KIT+ 5 предметов [11/21] Tool operation and connection
Содержание
- Operator s manual 1
- Инструкция по эксплуатации 1
- Operator s manual 2
- Page01 2
- Page02 3
- Page03 4
- Page04 5
- Operator s manual 6
- Page05 6
- Operator s manual 7
- Page06 7
- Safety operation 7
- Caution 8
- Not to do 8
- Operator s manual 8
- Page07 8
- Carefully ready these instructions before using the equipment and refer to this manual in case of doubts on its operation store all the documentation in place that can be handy for any user the employer undertakes to make sure users read and understand the entire manual before using the tool however during installation and use of the equipment the operator should use all of his experience and knowledge in order to avoid damages observe safety requirements and law regulations protecting your ears when using the equipment is mandatory since a long exposure to noise sources can cause serious sight and breathing damages to protect yourself from any foreign body moved by the airstream wear safety gloves if necessary wear safety gear and shoes suitable to the job to be performed do not wear loose clothes or with moving parts which can get cogged in the pneumatic tools moving parts tie back long hair since this manual refers to international standards we recommend to previously obtain informa 9
- Caution 9
- Operator s manual 9
- Page08 9
- Technical specifications 9
- Accessories kit 10
- Operator s manual 10
- Page09 10
- Start up and use 10
- Operator s manual 11
- Page10 11
- Tool operation and connection 11
- Maintenance 12
- Operator s manual 12
- Page11 12
- Operator s manual 13
- Page12 13
- Troubleshooting 13
- Warranty 13
- Warranty refer to defects of materials and components and do not refer to components subject to natural wear and maintenance work only machines cleaned from dust and dirt in original factory packing fully completed provided with instruction manual warranty card with fixed sales date with a shop stamp factory serial number and originals of sales and ware receipt issued by salesman are subjects of warranty within the warranty period the service center eliminate free of charge all detected production defects the manufacturer disclaims warranty and legal responsibilities if nonobservance of the instruction manual by user unqualified disassembling repair or maintenance of the machine as well does not bear responsibility for caused injury to persons or damages 13
- Page13 14
- Гиьад 14
- Инструкция по эксплуатации 14
- Правила безопасности 14
- Page14 15
- Важно 15
- Гиьад 15
- Запрещается 15
- Инструкция по эксплуатации 15
- Page15 16
- Важно 16
- Инструкция по эксплуатации 16
- Ключайте подачу сжатого воздуха только после подсоединения инструмента 16
- Технические характеристики 16
- Шрад 16
- Page16 17
- Инструкция по эксплуатации 17
- Комплектация 17
- Пуск и эксплуатация 17
- Page17 18
- Инструкция по эксплуатации 18
- Подключение и эксплуатация пневмоинструмента 18
- Page18 19
- Инструкция по эксплуатации 19
- Техническое обслуживание 19
- Page19 20
- Гарантийные обязательства 20
- Инструкция по эксплуатации 20
- Ирад 20
- Неисправности и способы их устранения 20
- Cover 2 21
Похожие устройства
- Fubag INTIG 200 AC/DC PULSE + горелка FB TIG 26 5P 4m Инструкция по эксплуатации
- Fubag AIR MASTER KIT + 6 предметов Инструкция по эксплуатации
- Fubag IW680 234л/мин 680н/м 6,3 бар 1/2 Инструкция по эксплуатации
- Fubag IW900 1/2u0022 880Нм 6,3бар Инструкция по эксплуатации
- Fubag WHS 210 DC Honda_220В Инструкция по эксплуатации
- Fubag WHS 210 DDC Honda_380-220В Инструкция по эксплуатации
- Fubag WS 230 DC ES 220В Инструкция по эксплуатации
- Fubag IW900 880Нм 6,3бар 1/2u0022 + набор головок кейс Инструкция по эксплуатации
- Fubag IW680 234л/мин 680н/м 6,3 бар 1/2 + набор кейс Инструкция по эксплуатации
- Fubag pws312 158л/мин 312н/м 6,3бар 1/2u0022 + набор кейс Инструкция по эксплуатации
- Uniel U-STR-1000/1 Инструкция по эксплуатации
- Uniel U-ARS-1500/1 09623 Инструкция по эксплуатации
- Electrolux ETB-16 BASIC Инструкция по эксплуатации
- Rexant RX-527 H белый Инструкция по эксплуатации
- Ballu S2 BHC-L 10-S06 Инструкция по эксплуатации
- Timberk AERO II TCH WS3 5MS Инструкция по эксплуатации
- Timberk AERO II TCH WS3 3M Инструкция по эксплуатации
- Ballu BHC-H10T12-PS Инструкция по эксплуатации
- Ballu BHC-M15T09-PS Инструкция по эксплуатации
- Ballu BHC-M20T24-PS Инструкция по эксплуатации
fubag Operator s manual www fubag ru The absence of pressure in the head facilitates subsequent restart When air is used the compressor restarts automatically when the lower calibration value is reached approx 2 bar between upper and lower The pressure inside the reservoir can be checked on the gauge provided fig 8 The compressor continues to operate automatically with this work cycle until the position of the switch of the pressure switchis modified To use the compressor again wait at least 10 seconds after this has been switched off before restarting Air pressure can be regulated in order to optimize use of air powered tools operating on the knob with the valve open pulling it up and turning it in a clockwise direction to increase pressure and counterclockwise to reduce this fig 9a 9b 9c 9d Once you have set the value required push the knob down to lock it Please check that the air consumption and the maximum working pressure of the pneumatic tool to be used are compatible with the pressure set on the pressure regulator and with the amount of air supplied by the compressor When you have finished working stop the machine pull out the plug and empty the reservoir fig 10 11 5 Tool operation and connection The tool should be connected only to an air supply system including components specified in fig A except for spray guns which should be connected to a lubricator Provide for clean and dry compressed air with a suitable oil mixture Use the correct air treatment unit filter pressure regulator and lubricator The lubricator should apply 3 to 6 oil drops per minute Make sure spray guns are supplied with clean dry and filtered compressed air Hose maximum length between lubricator and tool should not exceed 10 meters Quick disconnect coupling fig 15A and the hose airflow should have sufficient capacity We recommend an air hose with an inner diameter of 10 mm Exclusively use genuine hoses accessories and tools In order to guarantee a good operation of the tool the compressed air maximus pressure should not exceed 6 bar unless otherwise specified Greater pressure may result in damages or toll excessive wear and therefore are not recommended Low working pressure may cause tool power decreasing or discontinuance To select the pressure to be used for each tool refer to the specific user s manual or to the instruction on the packaging Pneumatic hammers are not suitable for the demolition of reinforced concrete Before connecting accessories make sure the compressor is shut down Before operating the equipment put some oil drops in the air inlet opening of the pneumatic tool see fig 15D Assemble any accessory and connection on the tool Connect air hose to the tool 10