D-Link DGS-3000-28SC [31/45] Ip address assignment
![D-Link DGS-3000-28SC [31/45] Ip address assignment](/views2/1459196/page31/bg1f.png)
DGS-3000-28SC Layer 2 Managed Stackable Gigabit Switch Hardware Installation Guide
23
IP Address Assignment
An IP address must be assigned to each switch, which is used for communication with an SNMP network manager or
other TCP/IP application (for example BOOTP, TFTP). The Switch's default IP address is 10.90.90.90. The user may
change the default Switch IP address to meet the specification of your networking address scheme.
The Switch is also assigned a unique MAC address by the factory. This MAC address cannot be changed, and can be
found by entering the command "show switch" into the command line interface.
The Switch's MAC address also appears in the Device Information and System Information windows of the Web-
based management interface. The IP address for the Switch must be set before using the Web-based manager. The
Switch IP address can be automatically set using BOOTP or DHCP protocols, in which case the actual address
assigned to the Switch must be known.
SNMP Settings
Simple Network Management Protocol (SNMP) is an OSI Layer 7 (Application Layer) designed specifically for
managing and monitoring network devices. SNMP enables network management stations to read and modify the
settings of gateways, routers, switches and other network devices. Use SNMP to configure system features for proper
operation, monitor performance and detect potential problems in the Switch, switch group or network.
Managed devices that support SNMP include software (referred to as an agent), which runs locally on the device. A
defined set of variables (managed objects) is maintained by the SNMP agent and used to manage the device. These
objects are defined in a Management Information Base (MIB), which provides a standard presentation of the
information controlled by the on-board SNMP agent. SNMP defines both the format of the MIB specifications and the
protocol used to access this information over the network.
The Switch supports SNMP versions 1, 2c, and 3. The administrator may specify which version of SNMP to use to
monitor and control the Switch. The three versions of SNMP vary in the level of security provided between the
management station and the network device.
In SNMP v1 and v2, user authentication is accomplished using 'community strings', which function like passwords.
The remote user SNMP application and the Switch SNMP must use the same community string. SNMP packets from
any station that has not been authenticated are ignored (dropped).
The default community strings for the Switch used for SNMP v1 and v2 management access are:
• public - Allows authorized management stations to retrieve MIB objects.
• private - Allows authorized management stations to retrieve and modify MIB objects.
SNMP v3 uses a more sophisticated authentication process that is separated into two parts. The first part is to
maintain a list of users and their attributes that are allowed to act as SNMP managers. The second part describes
what each user on that list can do as an SNMP manager.
The Switch allows groups of users to be listed and configured with a shared set of privileges. The SNMP version may
also be set for a listed group of SNMP managers. Thus, a group of SNMP managers can be created to view read-only
information or receive traps using SNMP v1 while assigning a higher level of security to another group, granting
read/write privileges using SNMP v3.
Using SNMP v3 individual users or groups of SNMP managers can be allowed to perform or be restricted from
performing specific SNMP management functions. The functions allowed or restricted are defined using the Object
Identifier (OID) associated with a specific MIB. An additional layer of security is available for SNMP v3 in that SNMP
messages may be encrypted. To read more about how to configure SNMP v3 settings for the Switch read the section
entitled Management.
Содержание
- Table of contents 3
- Intended readers 5
- Notes notices and cautions 5
- Typographical conventions 5
- Safety cautions 6
- Safety instructions 6
- General precautions for rack mountable products 7
- Protecting against electrostatic discharge 8
- Chapter 1 introduction 9
- Features 9
- Switch description 9
- Front panel components 11
- Led indicators 11
- Rear panel description 12
- Side panel description 13
- Chapter 2 installation 14
- Installation guidelines 14
- Package contents 14
- Attaching brackets to a switch for rack mounting 15
- Installing the switch without a rack 15
- Connecting a dc power supply 16
- Mounting the switch in a standard 19 rack 16
- Power failure ac power 16
- Power on ac power 16
- Installing power cord retainer 17
- Installing sfp and sfp ports 21
- Connecting the rps to the rps port 22
- Dps 800 rack mount chassis 23
- Installing the rps into a rack mount chassis 23
- Chapter 3 connecting the switch 25
- Switch to end node 25
- Switch to switch 26
- Connecting to network backbone or server 27
- Chapter 4 introduction to switch management 28
- Connecting the console port 28
- Management options 28
- First time connecting to the switch 30
- Password protection 30
- Ip address assignment 31
- Snmp settings 31
- Chapter 5 web based switch configuration 33
- Introduction 33
- Logging onto the web manager 33
- Areas of the user interface 34
- Web based user interface 34
- Web pages 35
- Appendix a technical specifications 36
- Appendix section 36
- General 36
- Physical and environmental 36
- Led indicators 37
- Performance 37
- Port functions 39
- Appendix b cables and connectors 41
- Contact mdi x port mdi ii port 41
- Dgs 3000 28sc layer 2 managed stackable gigabit switch hardware installation guide 41
- Ethernet cable 41
- Figure b 1 the standard rj 45 port and connector figure b 1 the standard rj 45 port and connector 41
- Rj 45 pin assignments 41
- When connecting the switch to another switch a bridge or hub a normal cable is necessary please review these products for matching cable pin assignment the following diagrams and tables show the standard rj 45 receptacle connector and their pin assignments 41
- Console cable 42
- Console rj 45 pin assignments 42
- Dgs 3000 28sc layer 2 managed stackable gigabit switch hardware installation guide 42
- Figure b 2 console to rj 45 cable figure b 2 console to rj 45 cable 42
- Pin console db9 rs232 rj 45 42
- When connecting the switch a pc a console cable is necessary the following diagrams and tables show the standard console to dj 45 receptacle connector and their pin assignments 42
- Dgs 3000 28sc layer 2 managed stackable gigabit switch hardware installation guide 43
- Figure b 3 dps cb150 2ps cable figure b 3 dps cb150 2ps cable 43
- Pin 2 pin 14 pin 43
- Redundant power supply rps cable 43
- Rps 14 pin to two 2 pin dc power cable pin assignments 43
- When connecting the switch to a redundant power supply an rps cable is necessary please review these products for matching cable pin assignment the following diagrams and tables show the dps cb150 2ps receptacle connector and their pin assignments 43
- Warranties 44
- Technical support information 45
Похожие устройства
- D-Link DGS-3000-28SC Руководство пользователя _Web UI_
- D-Link DGS-3120-24SC/*EI Руководство пользователя _CLI_
- D-Link DGS-3120-24SC/*EI Руководство по установке
- D-Link DGS-3120-24SC/*EI Руководство пользователя _Web UI_
- D-Link DGS-3427 Руководство пользователя _CLI_
- D-Link DGS-3427 Руководство пользователя _Web UI_
- D-Link DXS-3400-24SC Руководство по установке
- D-Link DXS-3400-24SC Руководство пользователя _CLI_
- D-Link DXS-3400-24SC Руководство пользователя _Web UI_
- D-Link DXS-3400-24TC Руководство пользователя _CLI_
- D-Link DXS-3400-24TC Руководство по установке
- D-Link DXS-3400-24TC Руководство пользователя _Web UI_
- D-Link DGS-3120-24PC/*RI Краткое руководство по установке
- D-Link DGS-3120-24PC/*RI Руководство по установке
- D-Link DGS-3120-24PC/*RI Руководство пользователя _Web UI_
- D-Link DGS-3120-24PC/*RI Руководство пользователя _CLI_
- D-Link DGS-3120-24SC/*RI Руководство по установке
- D-Link DGS-3120-24SC/*RI Руководство пользователя _CLI_
- D-Link DGS-3120-24SC/*RI Руководство пользователя _Web UI_
- D-Link DGS-3120-24TC/*RI Краткое руководство по установке
Скачать
Случайные обсуждения
Ответы 1
Как открыть окно настроек информации о системе веб-интерфейса коммутатора DGS-3000-28SC?
2 года назад
Ответы 1
Какие поля можно настроить в DGS-3000-28SC Layer 2 Managed Stackable Gigabit Switch?
1 год назад