D-Link DGS-6604 [16/111] Module plug in frame
Превью страниц
Страница 16 /
111
![D-Link DGS-6604 [16/111] Module plug in frame](/views2/1459372/page16/bg10.png)
DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide
4
DGS-6604 Hardware Composition
The DGS-6604 hardware consists of a chassis, management card, line cards, power system and a fan system.
Chassis
The DGS-6604 uses a standard 19-inch chassis, which has a height of 280mm, a width of 484mm, and a depth
of 470mm. The chassis consists of the system module layer, fan layer, and power layer.
The layer that handles system modules consists of a module plug-in frame, which is used for connecting the
various DGS-6604 modules.
The built-in power shelf is located at the top of the chassis.
The fan tray is located on the right-hand side of the chassis. The fan tray consists of eight fans. The dimension of
each fan is 80x80x20mm.
Module Plug-in Frame
The module plug-in frame of the DGS-6604 consists of the module slots and the backplane.
The DGS-6604 supports four module slots. The slot at the top of the Switch can only be used for the control
management module. The other three slots can be used to connect to various line cards. All the modules
supported by the DGS-6604 are of the same height, width and depth. The dimensions of each module are a
height of 42mm, a width of 388mm, and a depth of 422mm. The modules of the DGS-6604 are inserted into the
Switch horizontally. The backplane of the DGS-6604 is used to interconnect the control management card and
the line cards that have been installed in the Switch.
The main functions of the DGS-6604 backplane are listed below:
• Providing a mechanism for transmitting various signals between the modules and providing channels
for high-speed communication.
• Acting as a passive backplane.
• Automatically identifying the type of line card that has been installed in each slot.
• Managing the load distribution among the installed power supplies.
When the slots of the DGS-6604 are fully populated, the modules of the DGS-6604 will have the following layout:
• One control management module.
• Three line card modules to meet the network requirements.
The slot number used for the Control Management module is 1. Slots 2, 3, and 4 are used for line card modules.
Содержание
204- Fcc warning
- Ce mark warning
- Chapter 2 installation 43
- Chapter 1 introduction 1
- Chapter 5 web based switch management 78
- Chapter 4 introduction to switch management 69
- Chapter 3 connecting the switch 65
- Chapter 6 maintenance 83
- Chapter 7 troubleshooting 86
- Typographical conventions
- Intended readers
- Safety suggestions
- Safety recommendations for removing and replacing batteries
- Safety recommendations for handling the switch
- Notes notices and cautions
- Safety precautions for installing and removing the switch
- Electrical safety
- Preventing static discharge damage
- Grounding requirements
- Laser safety
- Dgs 6604 product specifications
- Dgs 6600 series switch description
- Chapter 1 introduction
- Product features
- Dgs 6604 product appearance
- Module plug in frame
- Dgs 6604 hardware composition
- Chassis
- Product features
- Dgs 6608 product specifications
- Dgs 6604 ventilation heat dissipation system
- Dgs 6608 product appearance
- Module plug in frame
- Dgs 6608 hardware composition
- Chassis
- Dgs 6608 ventilation heat dissipation system
- Dgs 6600 cpu i o modules ac dc power
- Interface
- Dgs 6600 cm module
- Uart console interface
- Out of band management port
- Technical specifications
- Uart console interface
- Out of band management port
- Interface
- Dgs 6600 cm ii management module
- Technical specifications
- Interface
- Dgs 6600 24sc2xs module
- Technical specifications
- Interface
- Dgs 6600 24sc2xs c module
- Technical specifications
- Interface
- Dgs 6600 16xs d
- Technical specifications
- Interface
- Dgs 6600 48p module
- Technical specifications
- Interface
- Dgs 6600 48s module
- Technical specifications
- Interface
- Dgs 6600 48s c module
- Technical specifications
- Interface
- Dgs 6600 48t module
- Technical specifications
- Interface
- Dgs 6600 48ts module
- Technical specifications
- Interface
- Dgs 6600 8xg module
- Technical specifications
- Dgs 6600 pwr module
- Technical specifications
- Maximum output power of multiple supply modules for dgs 6604 3 1
- Maximum output power of multiple supply modules for dgs 6608 4 4
- Dgs 6600 pwrdc module
- Technical specifications
- Maximum output power of multiple supply modules for dgs 6604 3 1
- Maximum output power of multiple supply modules for dgs 6608 7 1
- Rack mounting requirements
- Installation site requirements
- Chapter 2 installation
- Ventilation requirements
- Power requirements
- System grounding requirements
- Safety grounding
- Lightning grounding
- Precautions for fiber connections
- Installation tool requirements
- Emi considerations
- Inventory
- Inspection requirements when unpacking the switch
- Verifying the installation
- Installation flowchart
- Installing the cabinet
- Cabinet installation precautions
- Simple installation steps
- Mounting the dgs 6600 series switch into the cabinet
- Cabinet mounting precautions
- Fan tray installation
- Figure 2
- Power supply installation
- Air filter installation
- System ground connection
- Simple grounding steps
- Grounding precautions
- Ground connection
- Connecting the power supply to the power module
- Simple power connection steps
- Power supply connection precautions
- Simple management module cable connection steps
- Removing line cards from the dgs 6600 series switch
- Connecting the management module cable
- Installing line cards in the dgs 6600 series switch
- Cable management precautions
- Cable management
- Simple external interface cable connection steps
- Simple cable management steps
- Connecting the external interface cables
- Connecting external interface cable precautions
- Installation checks
- Checking the power supply
- Checking the cables
- Checking the cabinet
- Switch to end node
- Chapter 3 connecting the switch
- Chassis to switch
- Connecting to network backbone or server
- Connecting the external interface cables
- Connecting external interface cable precautions
- Cable management precautions
- Cable management
- Simple external interface cable connection steps
- Simple cable management steps
- Connecting the management module cable
- Web based user interface
- Snmp based management
- Remote command line interface using telnet
- Management options
- Chapter 4 introduction to switch management
- To connect a terminal to the console port
- Connecting the console port
- Command line interface through the serial ports
- First time connecting to the switch
- Connecting to the ethernet management port
- Password protection
- Creating user accounts
- Saving configuration changes
- Snmp settings
- Management information base mib
- Introduction
- Chapter 5 web based switch management
- Enabling and configuring the web user interface
- Web based user interface web ui
- Logging onto the web manager
- Areas of the user interface
- Configuring the management interface using the web ui
- Chapter 6 maintenance
- Maintaining the ventilation system
- Maintaining the dgs 6600 series switch hardware
- Maintaining the dgs 6600 modules
- Dgs 6600 series switch monitoring function
- Remote maintenance
- Maintaining the power supply
- General flow chart for troubleshooting installation faults
- Chapter 7 troubleshooting
- Troubleshooting
- Fault 3 the line card leds do not light as expected when the switch is powered on
- Fault 2 the ac power module is not working
- Fault 1 the system login password has been forgotten
- Description
- Common troubleshooting procedures
- Troubleshooting
- Fault 6 the fan tray does not work the fan tray s led behavior is unusual
- Fault 5 the led of the control management module is abnormal
- Fault 4 the leds on a line card start to behave strangely after the line card has been working for a while
- Description
- Fault 8 illegible characters appear in the serial port console
- Fault 7 there is no output from the console when connected to the serial port
- Description
- Troubleshooting
- Technical specifications 6604
- General
- Appendix a technical specifications
- Environment
- Weight
- Technical specifications 6608
- Power supply fan
- General
- Dimensions
- Environment
- Weight
- Power supply fan
- Dimensions
- Sfp module models and technical specifications
- Connection modules
- Xfp module models and technical specifications
- Base t 100base tx 10base t port
- Appendix b connectors and connection media
- Sfp module models and technical specifications
- Optical fiber connection
Похожие устройства
-
D-Link DGS-3130-54TSРуководство по настройке -
D-Link DXS-3600-16SСжатое руководство пользователя -
D-Link DGS-1100-08P/AБыстрый старт -
D-Link DGS-1100-08P/BБыстрый старт -
D-Link DXS-3400-24TCКраткая инструкция -
D-Link DXS-1100-10TSСжатое руководство пользователя -
D-Link DGS-3620-28SCБыстрый старт -
D-Link DGS-3630-28TCЭксплуатационная инструкция -
D-Link dgs-1510-28Руководство по быстрому запуску -
D-Link dgs-1510-52Краткий обзор функций -
D-Link DGS-1100-08PDРуководство по работе с устройством -
D-Link DGS-6608Руководство пользователя _CLI_