DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide
5
DGS-6604 Ventilation/Heat Dissipation System
The DGS-6604 operates at a temperature of 0-50ºC. The hardware of the DGS-6604 has been thermally
designed so the surface temperature of the components does not exceed the allowed ambient temperature of
50ºC without affecting the reliability, security, and repairability of the Switch. The thermal design of the DGS-6604
hardware uses fans to induct air in a forced convection so that the equipment operates normally in the specified
environment. The diagram below shows the ventilation/heat dissipation system that has been implemented on
the DGS-6604.
Figure 1-2 DGS-6604 Ventilation/Heat Dissipation System
DGS-6608 Product Specifications
Product Features
• Powerful Expansion Capabilities
The DGS-6608 is capable of supporting strategic routing and IPv6. With support for multiple types of
line cards, the DGS-6608 allows users to customize their Switch configuration to meet their network
requirements.
• Hot-Swappable Line Cards, Fan Tray, and Power Supplies
The DGS-6608 supports the hot-swapping of line cards, the fan tray, and power supplies to
minimize disruption to the network when a fault occurs.
• Power Supply Redundancy
The DGS-6608 has two built-in power shelves that can host up to eight power modules. If the DGS-
6608 is running in a non-PoE environment, the Switch can operate using only two power supply. in a
worst case scenario with six 48-port PoE line cards installed, all 8 x PSUs inserting can meet the
power request. In this case, the system does not support RPS.
NOTE: The air flow direction for the DGS-6604 is from the left to the right.
Содержание
204- Fcc warning
- Ce mark warning
- Chapter 2 installation 43
- Chapter 1 introduction 1
- Chapter 5 web based switch management 78
- Chapter 4 introduction to switch management 69
- Chapter 3 connecting the switch 65
- Chapter 6 maintenance 83
- Chapter 7 troubleshooting 86
- Typographical conventions
- Intended readers
- Safety suggestions
- Safety recommendations for removing and replacing batteries
- Safety recommendations for handling the switch
- Notes notices and cautions
- Safety precautions for installing and removing the switch
- Electrical safety
- Preventing static discharge damage
- Grounding requirements
- Laser safety
- Dgs 6604 product specifications
- Dgs 6600 series switch description
- Chapter 1 introduction
- Product features
- Dgs 6604 product appearance
- Module plug in frame
- Dgs 6604 hardware composition
- Chassis
- Product features
- Dgs 6608 product specifications
- Dgs 6604 ventilation heat dissipation system
- Dgs 6608 product appearance
- Module plug in frame
- Dgs 6608 hardware composition
- Chassis
- Dgs 6608 ventilation heat dissipation system
- Dgs 6600 cpu i o modules ac dc power
- Interface
- Dgs 6600 cm module
- Uart console interface
- Out of band management port
- Technical specifications
- Uart console interface
- Out of band management port
- Interface
- Dgs 6600 cm ii management module
- Technical specifications
- Interface
- Dgs 6600 24sc2xs module
- Technical specifications
- Interface
- Dgs 6600 24sc2xs c module
- Technical specifications
- Interface
- Dgs 6600 16xs d
- Technical specifications
- Interface
- Dgs 6600 48p module
- Technical specifications
- Interface
- Dgs 6600 48s module
- Technical specifications
- Interface
- Dgs 6600 48s c module
- Technical specifications
- Interface
- Dgs 6600 48t module
- Technical specifications
- Interface
- Dgs 6600 48ts module
- Technical specifications
- Interface
- Dgs 6600 8xg module
- Technical specifications
- Dgs 6600 pwr module
- Technical specifications
- Maximum output power of multiple supply modules for dgs 6604 3 1
- Maximum output power of multiple supply modules for dgs 6608 4 4
- Dgs 6600 pwrdc module
- Technical specifications
- Maximum output power of multiple supply modules for dgs 6604 3 1
- Maximum output power of multiple supply modules for dgs 6608 7 1
- Rack mounting requirements
- Installation site requirements
- Chapter 2 installation
- Ventilation requirements
- Power requirements
- System grounding requirements
- Safety grounding
- Lightning grounding
- Precautions for fiber connections
- Installation tool requirements
- Emi considerations
- Inventory
- Inspection requirements when unpacking the switch
- Verifying the installation
- Installation flowchart
- Installing the cabinet
- Cabinet installation precautions
- Simple installation steps
- Mounting the dgs 6600 series switch into the cabinet
- Cabinet mounting precautions
- Fan tray installation
- Figure 2
- Power supply installation
- Air filter installation
- System ground connection
- Simple grounding steps
- Grounding precautions
- Ground connection
- Connecting the power supply to the power module
- Simple power connection steps
- Power supply connection precautions
- Simple management module cable connection steps
- Removing line cards from the dgs 6600 series switch
- Connecting the management module cable
- Installing line cards in the dgs 6600 series switch
- Cable management precautions
- Cable management
- Simple external interface cable connection steps
- Simple cable management steps
- Connecting the external interface cables
- Connecting external interface cable precautions
- Installation checks
- Checking the power supply
- Checking the cables
- Checking the cabinet
- Switch to end node
- Chapter 3 connecting the switch
- Chassis to switch
- Connecting to network backbone or server
- Connecting the external interface cables
- Connecting external interface cable precautions
- Cable management precautions
- Cable management
- Simple external interface cable connection steps
- Simple cable management steps
- Connecting the management module cable
- Web based user interface
- Snmp based management
- Remote command line interface using telnet
- Management options
- Chapter 4 introduction to switch management
- To connect a terminal to the console port
- Connecting the console port
- Command line interface through the serial ports
- First time connecting to the switch
- Connecting to the ethernet management port
- Password protection
- Creating user accounts
- Saving configuration changes
- Snmp settings
- Management information base mib
- Introduction
- Chapter 5 web based switch management
- Enabling and configuring the web user interface
- Web based user interface web ui
- Logging onto the web manager
- Areas of the user interface
- Configuring the management interface using the web ui
- Chapter 6 maintenance
- Maintaining the ventilation system
- Maintaining the dgs 6600 series switch hardware
- Maintaining the dgs 6600 modules
- Dgs 6600 series switch monitoring function
- Remote maintenance
- Maintaining the power supply
- General flow chart for troubleshooting installation faults
- Chapter 7 troubleshooting
- Troubleshooting
- Fault 3 the line card leds do not light as expected when the switch is powered on
- Fault 2 the ac power module is not working
- Fault 1 the system login password has been forgotten
- Description
- Common troubleshooting procedures
- Troubleshooting
- Fault 6 the fan tray does not work the fan tray s led behavior is unusual
- Fault 5 the led of the control management module is abnormal
- Fault 4 the leds on a line card start to behave strangely after the line card has been working for a while
- Description
- Fault 8 illegible characters appear in the serial port console
- Fault 7 there is no output from the console when connected to the serial port
- Description
- Troubleshooting
- Technical specifications 6604
- General
- Appendix a technical specifications
- Environment
- Weight
- Technical specifications 6608
- Power supply fan
- General
- Dimensions
- Environment
- Weight
- Power supply fan
- Dimensions
- Sfp module models and technical specifications
- Connection modules
- Xfp module models and technical specifications
- Base t 100base tx 10base t port
- Appendix b connectors and connection media
- Sfp module models and technical specifications
- Optical fiber connection
Похожие устройства
-
D-Link DGS-3130-54TSРуководство по настройке -
D-Link DXS-3600-16SСжатое руководство пользователя -
D-Link DGS-1100-08P/AБыстрый старт -
D-Link DGS-1100-08P/BБыстрый старт -
D-Link DXS-3400-24TCКраткая инструкция -
D-Link DXS-1100-10TSСжатое руководство пользователя -
D-Link DGS-3620-28SCБыстрый старт -
D-Link DGS-3630-28TCЭксплуатационная инструкция -
D-Link dgs-1510-28Руководство по быстрому запуску -
D-Link dgs-1510-52Краткий обзор функций -
D-Link DGS-1100-08PDРуководство по работе с устройством -
D-Link DGS-6608Руководство пользователя _CLI_
Узнайте о системе вентиляции и теплоотведения коммутаторов Layer 3. Подробности о горячей замене модулей и резервировании питания для надежной работы.