D-Link DGS-6604 — установка аппаратного обеспечения для управляемых коммутаторов Ethernet [73/111]
Превью страниц
Страница 73 /
111
![D-Link DGS-6604 [73/111] Installing line cards in the dgs 6600 series switch](/views2/1459372/page73/bg49.png)
DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide
61
Figure 2-14 Schematic diagram for removing a line card
Installing Line Cards in the DGS-6600 Series Switch
Carry out the following steps to install boards in the DGS-6600 Series Switch:
1. Remove the component card or blank panel as instructed in the section Removing Line Cards from the
DGS-6600.
2. Insert the new board into the guide rail of the vacant slot.
3. Use the levers on the left and right hand side to push the board into position and tighten the two captive
screws on the board using a straight screw driver.
CAUTION:
1. Take care not to hold the edge of the PCB or collide the components of the PCB.
2. Always use the levers to plug/unplug a PCB module. Never use force to remove a
PCB module.
Содержание
204- Fcc warning
- Ce mark warning
- Chapter 2 installation 43
- Chapter 1 introduction 1
- Chapter 5 web based switch management 78
- Chapter 4 introduction to switch management 69
- Chapter 3 connecting the switch 65
- Chapter 6 maintenance 83
- Chapter 7 troubleshooting 86
- Typographical conventions
- Intended readers
- Safety suggestions
- Safety recommendations for removing and replacing batteries
- Safety recommendations for handling the switch
- Notes notices and cautions
- Safety precautions for installing and removing the switch
- Electrical safety
- Preventing static discharge damage
- Grounding requirements
- Laser safety
- Dgs 6604 product specifications
- Dgs 6600 series switch description
- Chapter 1 introduction
- Product features
- Dgs 6604 product appearance
- Module plug in frame
- Dgs 6604 hardware composition
- Chassis
- Product features
- Dgs 6608 product specifications
- Dgs 6604 ventilation heat dissipation system
- Dgs 6608 product appearance
- Module plug in frame
- Dgs 6608 hardware composition
- Chassis
- Dgs 6608 ventilation heat dissipation system
- Dgs 6600 cpu i o modules ac dc power
- Interface
- Dgs 6600 cm module
- Uart console interface
- Out of band management port
- Technical specifications
- Uart console interface
- Out of band management port
- Interface
- Dgs 6600 cm ii management module
- Technical specifications
- Interface
- Dgs 6600 24sc2xs module
- Technical specifications
- Interface
- Dgs 6600 24sc2xs c module
- Technical specifications
- Interface
- Dgs 6600 16xs d
- Technical specifications
- Interface
- Dgs 6600 48p module
- Technical specifications
- Interface
- Dgs 6600 48s module
- Technical specifications
- Interface
- Dgs 6600 48s c module
- Technical specifications
- Interface
- Dgs 6600 48t module
- Technical specifications
- Interface
- Dgs 6600 48ts module
- Technical specifications
- Interface
- Dgs 6600 8xg module
- Technical specifications
- Dgs 6600 pwr module
- Technical specifications
- Maximum output power of multiple supply modules for dgs 6604 3 1
- Maximum output power of multiple supply modules for dgs 6608 4 4
- Dgs 6600 pwrdc module
- Technical specifications
- Maximum output power of multiple supply modules for dgs 6604 3 1
- Maximum output power of multiple supply modules for dgs 6608 7 1
- Rack mounting requirements
- Installation site requirements
- Chapter 2 installation
- Ventilation requirements
- Power requirements
- System grounding requirements
- Safety grounding
- Lightning grounding
- Precautions for fiber connections
- Installation tool requirements
- Emi considerations
- Inventory
- Inspection requirements when unpacking the switch
- Verifying the installation
- Installation flowchart
- Installing the cabinet
- Cabinet installation precautions
- Simple installation steps
- Mounting the dgs 6600 series switch into the cabinet
- Cabinet mounting precautions
- Fan tray installation
- Figure 2
- Power supply installation
- Air filter installation
- System ground connection
- Simple grounding steps
- Grounding precautions
- Ground connection
- Connecting the power supply to the power module
- Simple power connection steps
- Power supply connection precautions
- Simple management module cable connection steps
- Removing line cards from the dgs 6600 series switch
- Connecting the management module cable
- Installing line cards in the dgs 6600 series switch
- Cable management precautions
- Cable management
- Simple external interface cable connection steps
- Simple cable management steps
- Connecting the external interface cables
- Connecting external interface cable precautions
- Installation checks
- Checking the power supply
- Checking the cables
- Checking the cabinet
- Switch to end node
- Chapter 3 connecting the switch
- Chassis to switch
- Connecting to network backbone or server
- Connecting the external interface cables
- Connecting external interface cable precautions
- Cable management precautions
- Cable management
- Simple external interface cable connection steps
- Simple cable management steps
- Connecting the management module cable
- Web based user interface
- Snmp based management
- Remote command line interface using telnet
- Management options
- Chapter 4 introduction to switch management
- To connect a terminal to the console port
- Connecting the console port
- Command line interface through the serial ports
- First time connecting to the switch
- Connecting to the ethernet management port
- Password protection
- Creating user accounts
- Saving configuration changes
- Snmp settings
- Management information base mib
- Introduction
- Chapter 5 web based switch management
- Enabling and configuring the web user interface
- Web based user interface web ui
- Logging onto the web manager
- Areas of the user interface
- Configuring the management interface using the web ui
- Chapter 6 maintenance
- Maintaining the ventilation system
- Maintaining the dgs 6600 series switch hardware
- Maintaining the dgs 6600 modules
- Dgs 6600 series switch monitoring function
- Remote maintenance
- Maintaining the power supply
- General flow chart for troubleshooting installation faults
- Chapter 7 troubleshooting
- Troubleshooting
- Fault 3 the line card leds do not light as expected when the switch is powered on
- Fault 2 the ac power module is not working
- Fault 1 the system login password has been forgotten
- Description
- Common troubleshooting procedures
- Troubleshooting
- Fault 6 the fan tray does not work the fan tray s led behavior is unusual
- Fault 5 the led of the control management module is abnormal
- Fault 4 the leds on a line card start to behave strangely after the line card has been working for a while
- Description
- Fault 8 illegible characters appear in the serial port console
- Fault 7 there is no output from the console when connected to the serial port
- Description
- Troubleshooting
- Technical specifications 6604
- General
- Appendix a technical specifications
- Environment
- Weight
- Technical specifications 6608
- Power supply fan
- General
- Dimensions
- Environment
- Weight
- Power supply fan
- Dimensions
- Sfp module models and technical specifications
- Connection modules
- Xfp module models and technical specifications
- Base t 100base tx 10base t port
- Appendix b connectors and connection media
- Sfp module models and technical specifications
- Optical fiber connection
Похожие устройства
-
D-Link DGS-3130-54TSРуководство по настройке -
D-Link DXS-3600-16SСжатое руководство пользователя -
D-Link DGS-1100-08P/AБыстрый старт -
D-Link DGS-1100-08P/BБыстрый старт -
D-Link DXS-3400-24TCКраткая инструкция -
D-Link DXS-1100-10TSСжатое руководство пользователя -
D-Link DGS-3620-28SCБыстрый старт -
D-Link DGS-3630-28TCЭксплуатационная инструкция -
D-Link dgs-1510-28Руководство по быстрому запуску -
D-Link dgs-1510-52Краткий обзор функций -
D-Link DGS-1100-08PDРуководство по работе с устройством -
D-Link DGS-6608Руководство пользователя _CLI_
Подробное руководство по установке линий в управляемых коммутаторах Ethernet. Узнайте, как правильно установить и заменить компоненты для оптимальной работы устройства.