VALVE SUNTEC TV TECHNICAL DATA
The pressure of the nozzle line is adjusted with the adjusting screw of the TV valve. The oil in excess to nozzle require-
ment is dumped to the return. Two pipe system : oil in excess is returned to tank. One pipe system : oil in excess is
returned to pump suction.
TV : Pressure regulating valve
TV 40 01 1
VALVE
IDENTIFICATION
(Not all model combinations are available
Consult your Suntec representative)
Pressure range :
10 : 2 - 10 bars
40 : 7 - 40 bars
Regulation type :
01 : by screw
02 : by piston,
for modulating purpose
Revision number
Oil under pressure
By-passed oil
Intake
Return
To nozzle
Pressure
adjustment
Return
To nozzle
To tank
ot nruteR
suction
Oil under pressure
Oil under suction
By-passed oil
returned to tank,
or to suction
Intake
from Tank
TV
va lve
T pump
General
Weight 3 kg
Hydraulic data
Pressure ranges 10 : 2 - 10 bars
(delivery pressure setting : 7 bars)
40 : 7 - 40 bars
(delivery pressure setting : 20 bars)
Operating viscosity 4 - 450 cSt
Oil temperature 0 - 150°C max. in the valve.
Inlet G 3/4"
To nozzle G 3/4"
Return G 3/4"
Connection threads Cylindrical according to ISO 228/1
EN