Fluke 27 [10/30] Min max mode pushbutton
![Fluke 27 [10/30] Min max mode pushbutton](/views2/1005102/page10/bga.png)
27
Users Manual
6
function selector rotary switch in the mA/A position (ac or
dc).
G RANGE R Manual Range Mode
Pushbutton
Press once to enter manual range mode, press again to
increment range, press and hold for 2 seconds to return
to autorange. Meter returns to autorange if the function
selector is switched to any other position. There is no
autorange annunciator; absence of the manual range
annunciator indicates the meter is in autorange. If
RANGE is depressed (>1 second) while the function
switch is moved from OFF to any ON position, manual
ranging will be selected in all functions.
H REL L Relative Mode Pushbutton
Press momentarily to enter the Relative mode and store
the displayed reading. The display will read zero. Press
again to update the stored digital reading. Press and hold
for 2 seconds to exit the Relative mode. The Relative
mode stores a digital reading and displays the change
(difference) between the stored reading and any following
reading. For example, if the stored reading is 15.00 V and
the present readings is 14.10 V, the display will indicate -
0.90V. The analog bar graph continues to display the
actual reading (14.10V). If the difference exceeds 3999
counts (without overloading the input), OF (overflow) is
displayed. The Relative mode selects manual ranging;
changing ranges automatically exits the Relative mode.
I MIN/MAX Mode Pushbutton
Press momentarily to enter MIN/MAX mode, press again
to toggle between MIN and MAX indications. Press and
hold for 2 seconds to exit MIN/MAX mode. The meter
stores the minimum and maximum digital readings, and
will display either reading as selected by the operator.
Press the HOLD/RESET button to reset the MIN/MAX
readings to the present input. The MIN/MAX mode
selects manual ranging; use a range that can record the
maximum anticipated input. Range changes reset
previously recorded MIN/MAX readings. Exiting the
MIN/MAX mode does not reset the previously recorded
readings unless the range or function is changed. The
MIN/MAX mode overrides the Touch Hold
mode.
W Warning
To avoid electric shock or personal injury, do
not use Touch Hold
to determine that
circuits with dangerous voltages are de-
energized. Touch Hold
will not capture
unstable or noisy readings.
Содержание
- For iec 61010 cat iii meters only 1
- Multimeter 1
- Fluke corporation fluke europe b v p o box 9090 p o box 1186 everett wa 5602 b d eindhoven 98206 9090 the netherlands 2
- Limited warranty limitation of liability 2
- Register your meter at register fluke com 2 02 2
- Visit the fluke website at www fluke com 2
- Table of contents 3
- Title page 3
- Users manual 4
- Multimeter safety 5
- Warnings 5
- A amperes input terminal 9
- Com common terminal 9
- Digital display 9
- Function selector rotary switch 9
- Milliamp microamp input terminal 9
- Operating features 9
- Volt ohms diode test input terminal 9
- Min max mode pushbutton 10
- Range manual range mode pushbutton 10
- Rel relative mode pushbutton 10
- Warning 10
- Hold touch hol 11
- Max maximum annunciator 11
- Min minimum annunciator 11
- Mk resistance annunciators 11
- Mode annunciator 11
- Mode pushbutton 11
- Ns conductance range annunciator ns 11
- Relative annunciator 11
- Touch hol 11
- Analog bar graph display 12
- Decimal point range indicator 12
- Low battery annunciator 12
- Manual range annunciator 12
- Negative polarity annunciator 12
- Overflow indication 12
- Overload indication 12
- Warning 12
- Applications 13
- Beeper not illustrated 13
- Current ac dc 13
- Tilt bail adjustment 13
- Voltage ac dc 13
- Warning 13
- Diode test and continuity 14
- Resistance and diode test continuity 14
- Resistance measurement 14
- Conductance 15
- Leakage testing 15
- Analog bar graph application 16
- Using the analog bar graph 16
- Specific applications checking capacitors 17
- Specific applications contact bounce 17
- Specific applications nulling 17
- Operator maintenance 20
- Specific applications noisy resistance measurements 20
- Warnings 20
- Battery installation or replacement 21
- Figure 1 battery and fuse replacement 22
- Users manual 22
- Fuse replacement 23
- Fuse test 23
- Warning 23
- Warnings 23
- General maintenance 24
- Figure 2 replaceable parts 25
- Operator maintenance 25
- Service 26
- Specifications 27
Похожие устройства
- LG MS-2352T Инструкция по эксплуатации
- Ada 6D Maxliner А00138 Инструкция по эксплуатации
- Supra SFD-115U Инструкция по эксплуатации
- DBX DRIVERACK PA+ 2X6 Инструкция по эксплуатации
- Belkin AV10009qp2M Инструкция по эксплуатации
- LG E1069SD Инструкция по эксплуатации
- Supra SFD-111U Инструкция по эксплуатации
- Blue Weld Combi 132 821340 Инструкция по эксплуатации
- Fluke 27II Инструкция по эксплуатации
- LG MS-2352JS Инструкция по эксплуатации
- DBX DRIVERACK PA-EU Инструкция по эксплуатации
- LG F1480TDS5 Инструкция по эксплуатации
- Supra SFD-105U Инструкция по эксплуатации
- Geo-Fennel FL 40-Pocket II-HP 541100 Инструкция по эксплуатации
- LG MS-2352J Инструкция по эксплуатации
- DBX DRIVERACK PX Инструкция по эксплуатации
- Belkin F5C412eb300W Инструкция по эксплуатации
- Fluke 28II Инструкция по эксплуатации
- LG F1222NDR5 (Серебристый) Инструкция по эксплуатации
- Supra SFD-103U Инструкция по эксплуатации