Fluke 65 [2/12] Model 65 english instruction sheet page 2
Model 65 English Instruction Sheet
Page
2
WWarning
To avoid possible personal injury:
⇒ Caution - performance of procedures other than
those specified herein may result in hazardous
light exposure.
⇒ Do not stare into the laser beam or direct it
toward the eyes.
Caution
To avoid possible damage to the thermometer or
incorrect measurements:
⇒ Do not drop the thermometer or subject it to
violent shocks.
⇒ Do not operate the thermometer near large
electrical or magnetic fields.
⇒ Do not touch the object with the thermometer.
⇒ If the emissivity of the object is not 0.95, the
thermometer can indicate a temperature
different from the actual temperature. (See
"Emissivity.")
⇒ Keep the thermometer away from direct
sunlight or a strong source of light, hot objects
(70
o
C / 158
o
F), high temperatures, high
humidity, or dust during use and storage.
⇒ Do not apply sudden temperature changes to
the thermometer. Before taking measurements,
wait for the thermometer to return to a stable
temperature.
⇒ Do not touch the focal lens.
⇒ Condensation may form on the focal lens if the
thermometer moves quickly from a cold to a hot
environment. Before taking measurements, wait
for the condensation to dissipate.
Содержание
- Box contents 1
- Contacting fluke 1
- Infrared thermometer 1
- Instruction sheet 1
- Introduction 1
- Model 65 1
- Model 65 english instruction sheet page 1 1
- Model 65 infrared thermometer 1
- Model 65 english instruction sheet page 2 2
- W warning 2
- Components 3
- Model 65 english instruction sheet page 3 3
- Model 65 english instruction sheet page 4 4
- Pressing any of the three top pushbuttons wakes up the thermometer 4
- Pushbuttons 4
- Display elements 5
- Emissivity 5
- Emissivity is a value between 0 and 1 that indicates an object s ability to emit infrared energy emissivity is determined primarily by the object s composition and surface finish a polished non oxidized metallic surface has an emissivity value near 0 and a dull black surface has an emissivity value near 1 see emissivity of common materials 5
- Ensuring accuracy 5
- Model 65 english instruction sheet page 5 5
- The thermometer s sensitivity to emissivity is set at the factory to 0 5 if the emissivity of the object is not 0 5 the displayed temperature could differ from the actual surface temperature to reduce this difference apply black tape black matte paint or black magic marker to the object if it is safe to do so and measure the darkened surface 5
- Laser offset 6
- Model 65 english instruction sheet page 6 6
- Optical resolution 6
- Optical resolution also called field of view or distance to spot size ratio is the ratio of the thermometer s distance from the object s surface to the size of the area measured spot size the closer the thermometer is to the object the smaller the spot size the laser spot size does not indicate the measured spot size see laser offset 6
- Surface temperatures 6
- The laser beam is offset 18 mm 0 5 in from the focal lens choose a sampling spot large enough to include the laser offset 6
- The minimum spot size is 25 mm 1 in which occurs at a distance of 200 mm 8 in from the object you cannot measure a smaller spot size by getting closer 6
- The temperature displayed is an average temperature within the spot size hot spots can be missed if the spot size is too large get as close as possible but no closer than 200 mm 8 in 6
- The thermometer has an 8 1 optical resolution 6
- The thermometer measures the first surface it detects even a glass cover dust or fog make sure the object is not obstructed 6
- And aim the laser beam in the center of the area to be measured the display shows the measured temperature 7
- If the emissivity of the object is different from 0 5 apply black tape black matte paint or black magic marker to the object if it is safe to do so see the section emissivity of common materials 7
- Measuring temperatures 7
- Model 65 english instruction sheet page 7 7
- Out of range hi flashes 7
- Out of range lo flashes 7
- Out of range temperatures 7
- Point the thermometer at the object 7
- Read the section ensuring accuracy before measuring temperatures check that the batteries are installed and the laser switch is in the on position see the sections installing the batteries and setting the switches 7
- Temperature display 7
- Temperature does not flash 7
- Temperature flashes 7
- The display indicates when a measured temperature reaches the detection limits of the thermometer when you recall an out of range temperature the display shows lo and hi as 7
- To take a measurement 7
- Cleaning the case and holster 8
- Cleaning the focal lens 8
- Installing the batteries 8
- Maintenance 8
- Model 65 english instruction sheet page 8 8
- Calibration 9
- Fluke recommends that you return the thermometer annually to a fluke service center for calibration starting one year after purchase 9
- Model 65 english instruction sheet page 9 9
- Setting the switches 9
- The factory settings are in the on positions the on position is to the right and the off position is to the left 9
- The switches enable the laser beam and display backlight to activate the laser press 9
- Troubleshooting 9
- Emissivity of common materials 10
- Model 65 english instruction sheet page 10 10
- Model 65 english instruction sheet page 11 11
- Specifications 11
- Approval us 21 cfr subchapter j part 1040 0 iec 60825 1 1998 01 edition 1 en 60825 1 1994 a11 1996 12
- Laser safety warning 12
- Model 65 english instruction sheet page 12 12
- Safety regulatory compliance p certification 12
- The following laser safety warning appears on the top back of the thermometer and the holster 12
- Warranty 12
Похожие устройства
- Digitech HOT HEAD DISTORTION Инструкция по эксплуатации
- Belkin F8N157ea001 Инструкция по эксплуатации
- Supra SNP-503 Инструкция по эксплуатации
- Beko WKB 51021 PTA Инструкция по эксплуатации
- LG MH-6652T Инструкция по эксплуатации
- Geo-Fennel FLG 500 HV-G Green 231500 Инструкция по эксплуатации
- Digitech SCOTT IAN BLACK 13 Инструкция по эксплуатации
- LG MH-6652F Series Инструкция по эксплуатации
- Fluke 705 Инструкция по эксплуатации
- Supra SNP-501 Инструкция по эксплуатации
- Hotpoint-Ariston ARUSF 105 Инструкция по эксплуатации
- Ada Basis (с поверкой) Инструкция по эксплуатации
- Fluke 707 Инструкция по эксплуатации
- LG MH-6646QMS Инструкция по эксплуатации
- Supra SNP-433 Инструкция по эксплуатации
- Digitech XMM METAL MASTER Инструкция по эксплуатации
- Hotpoint-Ariston ARSD 129 Инструкция по эксплуатации
- Ada 5D Crosspoint Set А00192 Инструкция по эксплуатации
- Fluke 707 ex Инструкция по эксплуатации
- Supra SNP-431 Инструкция по эксплуатации