Fluke 715 [15/16] English instruction sheet page 15

715 English Instruction Sheet
Page 15
General Specifications
Maximum voltage applied between any jack and earth
ground or between any two jacks: 30 V
Storage temperature: -40°C to 60°C
Operating temperature: -10°C to 55°C
Operating altitude: 3000 meters maximum
Temperature coefficient: ±0.005% of range per °C for the
temperature ranges -10 to 18°C and 28 to 55°C
Relative humidity: 95% up to 30°C, 75% up to 40°C, 45% up to
50°C, and 35% up to 55°C
Vibration: Random 2 g, 5 to 500 Hz
Shock: 1 meter drop test
Safety: Certified as compliant to CAN/CSA C22.2 No.
1010.1:1992. Complies with ANSI/ISA S82.01-1994.
Power requirements: Single 9 V battery (ANSI/NEDA 1604A or
IEC 6LR61)
Size: 32 mm H x 87 mm W x 187 mm L (1.25 in H x 3.41 in W x
7.35 in L);
With holster: 52 mm H x 98 mm W x 201 mm L (2.06 in H x 3.86
in W x 7.93 in L)
Weight: 349 g (12.3 oz);
With holster: 601 g (21.2 oz)
Скачать