Galletti LCE 364 HS [46/64] Lce hs 042 052 062 072 082 091 092 094 101 102 104 121 122 124

Galletti LCE 364 HS [46/64] Lce hs 042 052 062 072 082 091 092 094 101 102 104 121 122 124
LCE
RG66004766_rev.05
46
Cooling mode: outdoor air temperature 35°C, water temperature 12°C / 7°C
Heating mode: outdoor air temperature 7°C dry bulb and 6.2°C wet bulb, water temperature 40°C/45°C
Sound power measured according to standards ISO 3741 - ISO 3744 and EN 29614-1
Sound pressure measured at a distance of 10 m and a height of 1.5 m above the ground in a clear field.
Approx, capacity (kW) 45 50 60 70 80 120
Efficiency Pack 2 2 2 2 2 1 2 4 1 2 4 1 2 4
LCE…HS 042 052 062 072 082 091 092 094 101 102 104 121 122 124
Power supply V-ph-Hz
Cooling capacity kW - - 63,3 69,2 76,5 92,3 92,2 - 102,8 103,5 - 124,1 123,6 126,4
Total power input in cooling mode kW - - 24,8 27,7 31,7 33,1 36,2 - 39,5 43,3 - 43,1 47,1 42,9
Rated current input A - - 42,23 46,89 53,33 56,95 61,81 - 67,09 73,3 - 74,13 80,59 73,92
EER - - 2,56 2,5 2,42 2,78 2,55 - 2,6 2,39 - 2,88 2,62 2,94
ESEER - - 3,89 3,93 3,78 3,45 3,88 - 3,4 3,75 - 3,88 4,09 4,09
Heating capacity kW - - 70,2 77,6 85,2 101,2 102,5 - 117,2 118,3 - 137,8 138,3 135
Total power input in heating mode kW - - 18,7 21,5 24,6 32,5 28,8 - 37,5 33,6 - 42,7 37,7 42,2
Rated current input A - - 35,53 37,05 41,96 55,97 50,06 - 63,93 57,72 - 73,53 65,48 72,81
COP - - 3,75 3,6 3,46 3,11 3,55 - 3,13 3,52 - 3,23 3,67 3,2
Maximum current input A - - 60 64 75 91 91 - 101 101 - 119 119 120
Starting current A - - 195 192 200 261 261 - 269 269 - 319 319 247
No, of scroll compressors / circuits - - 2 / 1 2 / 1 2 / 1 2 / 2 2 / 1 - 2 / 2 2 / 1 - 2 / 2 2 / 1 4 / 2
No, of axial fans - - 44466 - 6 6- 888
Air flow rate m
3
/h - - 21379 21379 21379 30913 30913 - 30913 30913 - 41340 41340 41340
Water flow rate (cooling) l/h - - 10887 11902 13158 15858 15858 - 17665 17665 - 21346 21346 21747
Pressure drop, water side (cooling) kPa - - 46 34 42 31 31 - 38 38 - 39 39 40
Available head, standard pump (cooling) kPa - - 126 133 119 130 130 - 119 119 - 108 108 106
Buffer tank dm
3
- - 200 200 200 220 220 - 220 220 - 340 340 340
Expansion tank dm
3
- - 12 12 12 12 12 - 12 12 - 12 12 12
Plumbing connections " - - 2 2 2 2 2 - 2 2 - 2 1/2 2 1/2 2 1/2
Height mm - - 1735 1735 1735 1735 1735 - 1735 1735 - 1735 1735 1679
Length mm - - 2090 2090 2090 2442 2442 - 2442 2442 - 3190 3190 3540
Depth mm - - 1183 1183 1183 1183 1183 - 1183 1183 - 1183 1183 1183
Sound power level dB(A) 84,0 84,0 84,0 82,0 86,0 82,0 86,0 - 82,0 86,0 82,0
Sound pressure level dB(A) 56,0 56,0 56,0 54,0 58,0 54,0 58,0 - 54,0 58,0 54,0
Base unit operating weight kg - - 540 570 650 730 730 - 730 730 - 1010 1010 1050
Unit with pump and full tank operating weight kg - - 877 907 987 1138 1138 - 1138 1138 - 1581 1581 1641
Rated technical data of LCE heat pumps, STANDARD version
90 100
400-3-50

Содержание

Скачать