Emotron FLD48-016-2Y [62/68] Environmental conditions

Emotron FLD48-006-54 [62/68] Environmental conditions
58 Technical Data CG Drives & Automation 01-6142-01r0
8.6 Environmental conditions
Table 30 Operation
Parameter Normal operation
Nominal ambient temperature 0
°C–40 °C (32 °F - 104 °F) See table, see chapter 8.3 page 56 for different conditions
Atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI)
Relative humidity
according to IEC 60721-3-3
Class 3K4, 5...95% and non condensing
Contamination,
according to IEC 60721-3-3
No electrically conductive dust allowed. Cooling air must be clean and free from corrosive
materials. Chemical gases, class 3C2. Solid particles, class 3S2.
Vibrations
According to IEC 600068-2-6, Sinusodial vibrations:
10<f<57 Hz, 0.075 mm (0.00295 ft)
57<f<150 Hz, 1g (0,035 oz)
Altitude
0–1000 m (0 - 3280 ft)
480V AC drives, with derating 1%/100 m (328 ft) of rated current up to 4000 m (13123 ft)
690V AC drives, with derating 1%/100 m (328 ft) of rated current up to 2000 m (6562) ft
Coated boards required for 2000 - 4000 m(6562 - 13123 ft)
Table 31 Storage
Parameter Storage condition
Temperature -20 to +60 °C (-4 to + 140 °F)
Atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI)
Relative humidity
according to IEC 60721-3-1
Class 1K4, max. 95% and non condensing and no formation of ice.

Содержание