Fuji Electric FRN355VG1S-4J [1015/1046] Data of function codes cannot be changed from the keypad

Fuji Electric FRN315SVG1S-4J [1015/1046] Data of function codes cannot be changed from the keypad
13.5 If Neither an Alarm Code Nor "Light Alarm" Indication (
l-al
) Appears on the LED Monitor
13-39
Chap. 13 TROUBLESHOOTING
[ 3 ] Data of function codes cannot be changed from the keypad.
Possible Causes What to Check and Suggested Measures
(1) An attempt was made to
change function code data
that cannot be changed
when the inverter is
running.
Check if the inverter is running with Menu #3 "OPR MNTR" using the
keypad and then confirm whether the data of the function codes can be
changed when the motor is running, referring to the function code tables.
Î Stop the motor and then change the data of the function codes.
(2) The data of the function
codes is protected.
Check the data of function code F00 (Data Protection).
Î Change the data of F00 from "Enable data protection" (F00 = 1) to
"Disable data protection" (F00 = 0).
(3) The WE-KP terminal
command ("Enable data
change with keypad") is not
entered, though it has been
assigned to a digital input
terminal.
Check the data of function codes E01 through E09 and the input signal
status with Menu #4 "I/O CHECK" using the keypad.
Î Input a WE-KP command through a digital input terminal.
(4) The key was not pressed. Check whether you have pressed the key after changing the function
code data.
Î Press the
key after changing the function code data.
Î Check that "STORING…" is displayed on the LCD monitor.
(5) The data of function codes
F02 and E01 through E09
cannot be changed.
Either one of the FWD and REV terminal commands is turned ON.
Î Turn OFF both FWD and REV.
[ 4 ] Data of function codes cannot be changed via the communications link.
Possible Causes What to Check and Suggested Measures
(1) An attempt was made to
change function code data
that cannot be changed
when the inverter is
running.
Check if the inverter is running with Menu #3 "OPR MNTR" using the
keypad and then confirm whether the data of the function codes can be
changed when the motor is running, referring to the function code tables.
Î Stop the motor and then change the data of the function codes.
(2) The data of the function
codes is protected.
Check the data of function code F00 (Data Protection).
Î Change the data of F00 from "Enable data protection" (F00 = 1) to
"Disable data protection" (F00 = 0).
(3) The WE-LK terminal
command ("Enable data
change via communications
link") is not entered, though
it has been assigned to a
digital input terminal.
Check the data of function codes E01 through E09 and the input signal
status with Menu #4 "I/O CHECK" using the keypad.
Î Input a WE-LK command through a digital input terminal.
(4) The "Full save function"
(H02) was not executed.
Check that the "Full save function" was executed (H02 = 1).
Î If data of function codes is changed via the communications link,
execute the "Full save function"; otherwise, turning the power OFF
loses the changed data.
(5) The data of function code
F02 cannot be changed.
Either one of the FWD and REV terminal commands is turned ON.
Î Turn OFF both FWD and REV.