Fuji Electric FRN355VG1S-4J [1039/1046] App d inverter generating loss

Fuji Electric FRN22VG1S-2J [1039/1046] App d inverter generating loss
App. D Inverter Generating Loss
A-21
App.
App. D Inverter Generating Loss
The table below lists the inverter generating loss.
zHD specification generating loss
Low carrier
Medium carrier
(At time of F26 factory
default setting)
High carrier
Power
supply
voltage
Standard
applicable
motor
capacity
[kW]
Inverter type
F26
[kHz]
Generating loss
[W]
Generating loss
[W]
F26
[kHz]
Generating loss
[W]
0.75 FRN0.75VG1S-2J 2 70 95 15 100
1.5 FRN1.5VG1S-2J 2 100 125 15 130
2.2 FRN2.2VG1S-2J 2 130 165 15 170
3.7 FRN3.7VG1S-2J 2 190 245 15 260
5.5 FRN5.5VG1S-2J 2 240 295 15 310
7.5 FRN7.5VG1S-2J 2 300 390 15 415
11 FRN11VG1S-2J 2 450 580 15 620
15 FRN15VG1S-2J 2 540 670 15 700
18.5 FRN18.5VG1S-2J 2 660 825 15 860
22 FRN22VG1S-2J 2 790 995 15 1040
30 FRN30VG1S-2J 2 1300 1400 15 1450
37 FRN37VG1S-2J 2 1300 1500 15 1550
45 FRN45VG1S-2J 2 1450 1600 15 1600
55 FRN55VG1S-2J 2 1750 1900 15 1900
75 FRN75VG1S-2J 2 2300 2450 10 2550
Three-
phase
200 V
90 FRN90VG1S-2J 2 2750 2900 10 3050
3.7 FRN3.7VG1S-4J 2 150 215 15 230
5.5 FRN5.5VG1S-4J 2 170 280 15 300
7.5 FRN7.5VG1S-4J 2 230 375 15 400
11 FRN11VG1S-4J 2 300 480 15 520
15 FRN15VG1S-4J 2 360 560 15 610
18.5 FRN18.5VG1S-4J 2 440 715 15 770
22 FRN22VG1S-4J 2 510 835 15 900
30 FRN30VG1S-4J 2 850 1100 15 1150
37 FRN37VG1S-4J 2 1050 1400 15 1450
45 FRN45VG1S-4J 2 1150 1500 15 1600
55 FRN55VG1S-4J 2 1400 1850 15 1950
75 FRN75VG1S-4J 2 1750 1950 10
*1
2150
90 FRN90VG1S-4J 2 2000 2350 10
*1
2600
110 FRN110VG1S-4J 2 2400 2750 10
*1
3050
132 FRN132VG1S-4J 2 2650 3000 10
*1
3300
160 FRN160VG1S-4J 2 3200 3650 10
*1
4000
200 FRN200VG1S-4J 2 4000 4550 10
*1
5000
220 FRN220VG1S-4J 2 4500 5100 10
*1
5600
280 FRN280VG1S-4J 2 5500 6300 10
*1
6900
315 FRN315VG1S-4J 2 6250 7100 10
*1
7800
355 FRN355VG1S-4J 2 6750 7650 10
*1
8450
400 FRN400VG1S-4J 2 7650 8750 10
*1
9650
500 FRN500VG1S-4J 2 9950 10700 5
*1
10700
Three-
phase
400 V
630 FRN630VG1S-4J 2 12350 13300 5
*1
13300
(*1) If the generating loss set in F26 exceeds the value specified in this table, it is set to the same generating loss as that applied
with the high carrier set regardless of the value in F26.