Hitachi RAD-50DH7 [2/38] Safety precaution
![Hitachi RAD-50DH7 [2/38] Safety precaution](/views2/1334956/page2/bg2.png)
– 2 –
!
SAFETY PRECAUTION
●
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
●
Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which,
if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may
result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
●
The sign indicate the following meanings.
●
Please keep this manual after reading.
WARNING
PRECAUTIONS DURING INSTALLATION
●
Do not reconstruct the unit.
Water leakage, fault, short circuit or fire may occur if you reconstruct the
unit by yourself.
●
Please ask your sales agent or qualified technician for the installation of
your unit. Water leakage, short circuit or fire may occur if you install the unit
by yourself.
●
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or
the earth line of telephone. Improper installation of earth line may cause
electric shock.
●
A circuit breaker should be installed depending on the mounting site of the
unit. Without a circuit breaker, the danger of electric shock exists.
●
Do not install near location where there is flammable gas. The outdoor unit
may catch fire if flammable gas leaks around it.
●
Please ensure smooth flow of water when installing the drain hose.
CAUTION
!
!
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
PRECAUTIONS DURING OPERATION
●
Avoid an extended period of direct air flow for your health.
W
A
R
N
I
N
G
!
●
Should abnormal situation arises (like burning smell), please stop operating the unit
and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may
occur if you continue to operate the unit under abnormal situation.
●
Please contact your agent for maintenance. Improper self maintenance may cause
electric shock and fire.
●
Please contact your agent if you need to remove and reinstall the unit. Electric
shock or fire may occur if you remove and reinstall the unit yourself improperly.
●
If the supply cord is damaged, it must be replaced by the special cord obtainable
at authorized service/parts centers.
●
Do not insert a finger, a rod or other objects into the air outlet or inlet. As the
fan is rotating at a high speed, it will cause injury. Before cleaning, be sure
to stop the operation and turn the breaker OFF.
●
During thunder storm, disconnect and turn off the circuit breaker.
●
Do not use any conductor as fuse wire, this could cause fatal accident.
!
Make sure to connect earth line.
Indicates the instructions that must be followed.
The sign in the figure indicates prohibition.
W
A
R
N
I
N
G
!
(EN1) RAD/RAC-50/60/70DH7 13/4/07, 2:03 PM2
Содержание
- English 1
- Indoor unit outdoor unit 1
- Rad 50dh7 rac 50dh7 rad 60dh7 rac 60dh7 rad 70dh7 rac 70dh7 1
- Split type air conditioner 1
- Safety precaution 2
- English 3
- Precautions during operation 3
- Indoor unit 4
- Model name and dimensions 4
- Names and functions of each part 4
- Outdoor unit 4
- English 5
- I this controls the operation function and timer setting of the room air conditioner 5
- Names and functions of remote control unit 5
- Start stop button 5
- Automatic operation 6
- I auto restart control 6
- Start stop 6
- Various functions 6
- English 7
- Heating operation 7
- Start stop 7
- Dehumidifying operation 8
- I dehumidifying function 8
- Start stop 8
- Cooling operation 9
- English 9
- Start stop 9
- 1 0 1 5 9 5 10 11 12 10
- Off time setting 10
- On time setting 10
- Press the cancel button 10
- Press the reserve button 10
- Timer reservation 10
- English 11
- How to cancel reservation 11
- How to set the sleep timer 11
- Explanation of the sleep timer 12
- Circuit breaker 13
- English 13
- How to use the air conditioner effectively 13
- Suitable room temperature install curtain or blinds 14
- The ideal ways of operation 14
- Ventilation effective usage of timer 14
- English 15
- For user s information 15
- Interference from electrical products 15
- Not operating for a long time 15
- The air conditioner and the heat source in the room 15
- When lightning occurs 15
- Air filter 16
- Caution 16
- Maintenance 16
- Procedure 16
- Warning 16
- After sale service and warranty 17
- Are the doors or windows opened or is there any source of heat in the room 17
- Condition check the following points 17
- Does sunlight fall directly on the outdoor unit 17
- English 17
- Is the air flow of the outdoor unit obstructed 17
- Is the circuit breaker on 17
- Is the fuse all right 17
- Is the set temperature suitable 17
- Is the voltage extremely high or low 17
- Please check the following points by qualified service personal either every half yearly or yearly contact your sales agent or service shop 17
- Regular inspection 17
- Was the air filter cleaned 17
- When asking for service check the following points 17
- Rad 50dh7 rac 50dh7 rad 60dh7 rac 60dh7 rad 70dh7 rac 70dh7 19
- Кондиционер типа раскола 19
- Модель 19
- Наружний блок внутренний блок 19
- Русский 19
- Pyc1 rad rac 50 60 70dh7 13 4 07 2 11 pm 128 20
- Осторожно 20
- Указания по технике безопасности 20
- Маленьких детей должны контролироваться чтобы гарантировать что они не играют с прибором 21
- О с т о р о ж н о 21
- Русский 21
- Техика безопасности в ходе эксплуатации 21
- Внутренний блок 22
- Наименование модели и размесы 22
- Наименования и ф ункции каждого узла 22
- Наружный блок 22
- I этот пульт управляет работой внутреннего блока кондиционера и задает параметры таймера 23
- Наименование частей пульта дистанционного управления и их предназначение 23
- Русский 23
- I автоматический перезапуск 24
- Автоматический режим работы 24
- Различные функции 24
- Старт стоп 24
- Режим нагрева 25
- Русский 25
- Старт стоп 25
- I функция cушки 26
- Режим сушки 26
- Режим сушки следует использовать при температуре в помещении свыше 16 c при температуре в помещении ниже 15 c режим сушки не работает 26
- Старт стоп 26
- Режим охпаждения 27
- Русский 27
- Старт стоп 27
- 1 0 1 5 9 5 10 11 12 28
- Нажмите кнопку отмена 28
- Нажмите кнопку резерв 28
- Резервация времени 28
- Установка времени 28
- Отмена резервирования 29
- Русский 29
- Установка таймера задержки отключения 29
- Принцип действия таймера задержки отключения 30
- Выключатель прерыватель электроцепи 31
- Как эффективно использовать кондиционер 31
- Когда вы не используете комнатный кондиционер воздуха установите выключатель прерыватель электроцепи в положение выкл 31
- Русский 31
- Вентиляция 32
- Идеальный способ эксплуатации 32
- Использование штор или ставней 32
- Температура в помещении 32
- Устанавливайте подходящую t для грудных младенцев и детей 32
- Эффективное использование таймера 32
- Воздушный кондиционер и нагреватель в одном помещении 33
- Если кондиционер долго не используется 33
- Информация для пользователя 33
- Люфт от электрического шума 33
- Осторожно 33
- Предостережение 33
- Предупреждение 33
- При молниях 33
- Русский 33
- Гарантийное обслуживание 35
- Перед обрашением к специалисту проверьте нижеперечисленные 35
- Профилактические осмотры 35
- Русский 35
- Примечание 36
- Русский 37
Похожие устройства
- Hitachi RAD-50DH7 Технические данные
- Hitachi RAC-50DH7 Инструкция по эксплуатации
- Hitachi RAC-50DH7 Технические данные
- Hitachi RAC-60DH7 Инструкция по эксплуатации
- Hitachi RAC-60DH7 Технические данные
- Hitachi RAC-70DH7 Инструкция по эксплуатации
- Hitachi RAC-70DH7 Технические данные
- Hitachi RAI-25NH5 Инструкция по эксплуатации
- Hitachi RAI-25NH5 Инструкция по монтажу
- Hitachi RAI-35NH5 Инструкция по эксплуатации
- Hitachi RAI-35NH5 Инструкция по монтажу
- Hitachi RAI-50NH5 Инструкция по эксплуатации
- Hitachi RAI-50NH5 Инструкция по монтажу
- Hitachi RAD-18NH7 Инструкция по эксплуатации
- Hitachi RAD-18NH7 Инструкция по монтажу
- Hitachi RAD-25NH7 Инструкция по эксплуатации
- Hitachi RAD-25NH7 Технические данные
- Hitachi RAD-35NH7 Инструкция по эксплуатации
- Hitachi RAD-35NH7 Технические данные
- Hitachi RAK-25NH5 Инструкция по эксплуатации