Tecorp HC2V9P42P2 Инструкция по эксплуатации онлайн [91/182] 475057

Tecorp HC2V9P42P2 Инструкция по эксплуатации онлайн [91/182] 475057
High Performance Vector Control/Torque Control Inverter User Manual
Chapter 6 Parameter Description 69
Fig.6-7 Process open loop main and auxiliary reference calculation 3
Open loop combination reference f
com
=main reference f
m
+auxiliary reference f
a
-50% bias
4: Max: Get the maximum value of the main reference f
m
and the auxiliary reference f
a
.
Fig.6-8 Process open loop main and auxiliary reference calculation 4
Open loop combination reference f
com
=Max {main reference f
m
, auxiliary reference f
a
}
5: Min: Get the minimum value of the main reference f
m
and the auxiliary reference f
a
.
Fig.6-9 Process open loop main and auxiliary reference calculation 5
Open loop combination reference f
com
=Min {main reference f
m
, auxiliary reference f
a
}
Note: When the corresponding frequency of the combination value f
com
exceeds the upper or lower limit
Frequency
Time
Frequency
Time
Frequency
Time
Frequency
Time
Frequency
Time
Frequency
Time