Tecorp HC2V9P42P2 [111/182] To 100 per unit value corresponds to 0 to 200 positive torque input as shown in the positive axis

Tecorp HC2V8P4200 [111/182] To 100 per unit value corresponds to 0 to 200 positive torque input as shown in the positive axis
High Performance Vector Control/Torque Control Inverter User Manual
Chapter 6 Parameter Description 89
Fig 6−23 Input analog characteristics curve
Display of operation panel
Unit’s digit
AI1 function selection
0: Open loop frequency or close loop
rotation speed reference;
1 Torque reference 1 (torque control
operation mode);
2: Torque reference 2 (torque control
operation mode);
3: Reserved;
4: Reserved;
5: Motor temperature feedback (overload
protection sensor mode);
6: Speed limiting (torque control operation
mode)
Tens place
AI2 function selection, the same as above;
Hundreds
place
AI3 function selection, the same as above;
Thousands
place
DI function selection, the same as above
P6.21 is used to select functions of AI1, AI2, AI3 and DI terminals. Since the using methods of AI1, AI2,
AI3 and DI are identical, AI1 is described as an example here:
0: Open loop frequency or analog close loop rotation velocity reference: AI1 analog input is converted
into setup frequency via the analog curve.
1: Torque reference 1: Determine the torque reference with the per-unit value converted from analog.
0 to 100% per-unit value corresponds to 0 to 200% positive torque input, as shown in the positive axis
zone in Fig.6-24.
When AI3 channel is used to input -10V to 10V, the per-unit value converted from input analog -100% to
100% corresponds to the -200% to 200% of the torque input in positive and negative directions, as
shown in the positive and negative axis zone in Fig.6-24.
P6.21 AI1AI3DI analog channel function selection
0~ 6666(0000)