belongs to and it is not influence accessing attribution of trap OID that notify belonged to. If
notify does not contain binded variable, sending notify is not effected on view.
For example:
! Add view «view1» ,and configure it to have a subtree «1.3.6.1»
QTECH(config)# snmp-server view view1 1.3.6.1 include
! Add a subtree «1.3.6.2» for existed view «view1»
QTECH(config)# snmp-server view view1 1.3.6.2 include
! Remove existed view «view1»
QTECH(config)# no snmp-server view view1
! Display configured view
QTECH(config)# show snmp view
Configure group
Use this configuration to configure a accessing conreol group. Folowing groups are default to
exist: (1) security model is v3,the security level is differentiated group initial ; (2) security model
is v3,the security level is differentiated encrypt group initial. At most 64 groups can be
configured. Configure it in global configuiration mode:
snmp-server group groupname { 1 | 2c | 3 [auth | noauth | priv] [context context-name]} [read
readview]
[ wrete writeview] [notify notifyview]
no snmp-server group groupname {1 | 2c | 3 [auth | noauth | priv] [context context-name]}
Display configured group in any configuration mode:
show snmp group
groupname means group name, which ranges from 1 to 32 characters,excluding space.
Readview is a view name, which means the right to read in the view. If the keyword is vacant,
it is default not to include readable view.
Writeview is a view name, which means the right to read and write in the view. If the keyword
is vacant, it is default not to include readable and writable view.
Notifyview is a view name, which means the right to send notification in the view. If the
keyword is vacant, it is default not to include notify sending view.
Context-name is facility context. If the keyword is vacant, it is default to be local facility.
For example:
! Add group «group1» to local facility,using security model 1, and configure read, write, and
notify view to be internet
QTECH(config)# snmp-server group group1 1 read internet write internet notify Internet
! Remove group «group1» from local facility
QTECH(config)# no snmp-server group group1 1
! Display current group configuration.
QTECH(config)# show snmp group
Configure user
Use this configuration to configure user for local engine and recognizable remote engine.
Following users are default to exist: (1)initialmd5 (required md5 authentication) ,(2) initialsha
(required sha authentication) ,(3) initialnone (non- authentication) . The above three users are
reserved for system not for user. The engine the user belonged to must be recognizable.
When deleting recognizable engine, contained users are all deleted. At most 64 users can be
configured. Configure it in global configuration mode:
snmp-server user username groupname [ remote host [ udp-port port ] ] [ auth { md5 | sha } {
authpassword { encrypt-authpassword authpassword | authpassword } | authkey { encrypt-