Qtech QSW-8200-28T-AC-DC [33/36] Ulpp flush enable mac vlan

Qtech QSW-8200-28T-AC-DC [33/36] Ulpp flush enable mac vlan
User Manual
Chapter 4. Commands for ULPP 33
www.qtech.ru
Usage Guide: Enable receiving the flush packets of updating MAC address table.
Example: Enable receiving the flush packets of updating the MAC address.
Switch(config)# interface ethernet 1/0/1
Switch(config-If-Ethernet1/0/1)# ulpp flush enable mac
4.26 ulpp flush enable mac-vlan
Command: ulpp flush enable mac-vlan
Function: Enable receiving the flush packets of mac-vlan type.
Parameter: None.
Default: Disable.
Command mode: Port mode.
Usage Guide: If enabling this function, configure the interface to receive the flush
packets handled mac-vlan type and delete the dynamic unicast mac according to vlan
information in the packets.
Example: Enable receiving the flush packets deleted by mac-vlan of port.
Switch(config)#interface e1/0/2
Switch(config-if-ethernet1/0/2)#ulpp flush enable mac-vlan
4.27 ulpp group
Command: ulpp group <integer>
no ulpp group <integer>
Function: Create a ULPP group. If this group exists, then enter the configuration mode
of ULPP group. The no command deletes a ULPP group.
Parameter: <integer> is the ID of ULPP group, range from 1 to 48.
Command mode: Global Mode.
Default: Any ULPP groups are not configured.
Usage Guide: None.
Example: Configure ulpp group 20 or enter the mode of ulpp group 20.
Switch(config)# ulpp group 20
Switch(ulpp-group-20)#
4.28 ulpp group master
Command: ulpp group <integer> master
no ulpp group <integer> master
Function: Configure the master port of ULPP group, the no command deletes the
master port.
Parameter: <integer> is the ID of ULPP group, range from 1 to 48.
Default: There is no master port configured by default.
Command mode: Port mode.